HomeMy WebLinkAbout913 Lafayette St_01102020WATERLOO FIRE RESCUE INSPECTION REPORT 913 LAFAYETTE ST, WATERLOO IA 50703 DETAILS Inspection Date: 01/10/2020 | Inspection Type: Rental Inspection | Inspection Number: 3940 | Shift: N/A | Station: N/A | Unit: N/A | Lead Inspector: BARRY STRATTON | Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1031.2 - Reliability Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON - Comments: Rear door needs replaced and also landing @ rear door. FAIL 605.1 - Abatement of electrical hazards Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Electrical service grounding is not to code. Back Strap in not hooked up to water service and grounding is interrupted by PEX water line. 220 V wire and box hanging from bungee cord and needs corrected. FAIL 907.2.11 - Single- and multiple-station smoke alarms Listed single- and multiple- station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY STRATTON - Comments: Smoke detectors needed in each bedroom, outside of bedrooms, and in basement. FAIL 915.4 - Carbon monoxide alarms Carbon monoxide alarms shall comply with Sections 915.4.1 through 915.4.3. Inspector: BARRY STRATTON - Comments: CO detectors needed in vicinity of the bedrooms. Need CO by front bedroom. FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Printed on 07/24/2020 @ 15:14 Page 1 of 3 STATUS CODE DESCRIPTION Inspector: BARRY STRATTON - Comments: Peeling paint and ceilings collapsing on tenants. Rear door not being able to secure is letting in cold air. Air is mixing with warm air on the inside and creating moisture which in-turn is creating mold to form on walls and foundation. FAIL R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Inspector: BARRY STRATTON - Comments: Front steps do not meet the code pertaining to rise in stairs from walk way to 1st step. FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY STRATTON - Comments: Front door is not weather tight. Rear door is damaged needs replaced. Door hardware not capable of securing door. Ceilings in living room, kitchen, and bathroom need repaired. Peeling paint needs corrected. Handrails needed to basement. Landing at rear door needs replaced. Landing is not capable of supporting imposed loads. FAIL R6.A. - Interior Structure- Unsafe Conditions Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Inspector: BARRY STRATTON - Comments: Peeling paint, landing @ rear door, electric service grounding, water heater supply lines, draft hood. FAIL R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F? (IPMC 602.2) Inspector: BARRY STRATTON - Comments: Furnace exhaust ducts supported off gas line. Have all ducts supported to code and removed from being supported off gas line. Need to install new thermostat for furnace. FAIL R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) Inspector: BARRY STRATTON - Comments: Water heater supply lines not installed to code. Draft hood not secured to water heater. Have licensed contractor installed to code. Water lines need to be supported on floor joist throughout basement. REINSPECTION DATE 02/10/2020 Printed on 07/24/2020 @ 15:14 Page 2 of 3 CONTACT SIGNATURE N8 Holdings LLC Signed on: 01/10/2020 @ 13:26 INSPECTOR SIGNATURE BARRY STRATTON Signed on: 01/10/2020 @ 13:24 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/24/2020 @ 15:14 Page 3 of 3