Loading...
HomeMy WebLinkAboutSandry Fire SupplyY FIRE SUPPLY 618 6th Street — DeWitt, IA 52742 CITY OF WATERLOO CITYCLERK'S OFFICE JUN 30 2021 PH2.291s r City Of Waterloo Attn: City Clerk 715 Mulberry Street Waterloo, IA 50703 Sealed Proposal: WFR SCBA Platform Replacement Project Bid ..9 • i • WoDaagkipues 8£6Z-985-888 rn0 ) r rt H C CO tat (Ts CAD CO 0) a TI 0 U') c D • v FIRE SUPPLY June 30, 2021 City of Waterloo 715 Mulberry St Waterloo, IA 50703 Re: City of Waterloo SCBA Proposal 618 6th Street DeWitt, IA 52742 1-888-586-2938 FAX: 563-659-8147 Thank you for allowing us the opportunity to propose the MSA G1 SCBAs. The features and benefits of the MSA G1 SCBA, along with its best in class warranty and very low cost of ownership, have made it the choice for more and more fire departments throughout the country. Sandry Fire Supply will work with the City of Waterloo to provide all the required paperwork and documentation required for this purchase. We provide on -site fit testing using an OHD machine and can provide the fit test reports. Sandry Fire Supply also offers on -site annual flow testing for service of your SCBA. Sandry Fire Supply will provide on -site SCBA use and care training to the members of the City of Waterloo at time of delivery, meeting or training night. This can be finalized as we work through the purchase process. We look forward to working with the City of Waterloo on this project. If you have any questions or concerns, please feel free to give us a call. Respectfully, Neal Stapelkamp 563-212-7766 SANORY FIRE SUPPLY Letter of Exceptions 618 6th Street DeWitt, IA 52742 1-888-586-2938 FAX 563-659-8147 No electrical connections will be preformed by Sandry Fire Supply during the compressor installation. All electrical work shall be provided by City of Waterloo. DOT Breathing Air cascade cylinders have changed to ISO/UN certification. Quantity 21 was quoted on the summary page for the spare batteries per the request. Quantity 11 was quoted on the summary page for the cascade cylinders per the request. Extended 3 year warranty available at time of purchase on the Breathing Air Compressor at a $600 additional charge. Item it WFR SCBA Platform Replacement Project Bid Sheet Self -Contained Breathing Apparatus DETAILS Company Name: Company Contact: Company Phone: Contact Email: Sandry Fire Supply LLC Neal Stapelkamp 563-212-7766 neal@sandryfire.com MEETS DOES NOT MEET EXCEPTION 1) The biological, SCBA shall radiological, be approved and nuclear to NIOSH protection 42 CFR, (CBRN). Part 84 for chemical, X 2) The Open SCBA shall -Circuit Self be compliant -Contained Breathing to the NFPA Apparatus 1981, 2019 for Emergency Edition, Standard Services. on X 3) The optional SCBA shall PASS Device), be compliant Standard to the on NFPA Personal 1982, Alert 2019 Safety Edition Systems. (if including X 4) All 913 locations electronics Class components I, Groups C and shall D, Class be approved II, Groups for E, Intrinisic F, and Safety G, Hazardous under UL X 5) The and pressure pressure facepiece-mounted maintain greater static. air to than the atmospheric facepiece positive pressure to satisfy by no more breathing the needs than regulator of 1.5 the inches shall user of supply at a water x 6) The 500 breathing standard liters regulator per shall minute. maintain positive pressure during flows of up to X 7) The requirement liters. breathing of regulator remaining shall positive also meet while or supplying exceed a dynamic a minute volume flow of 160 X 8) The shall regulator breathing pass through mounted regulator the to the shall left shoulder backframe. have attached strap to a medium couple to the pressure hose pressure -reducing which X 9) The the medium facepiece -pressure mounted hose breathing shall be regulator. equipped with a swivel attachment at X 10) The activated breathing by the regulator user's shall respirations. have a demand valve to deliver air to the user, X 11) The that components are not vulnerable of the to breathing corrosion. regulator shall be constructed of materials X 12) stop When doffing air flow and the regulator, release regulator. regulator disengagement shall simultaneously X 1of6 13) The SCBA shall have two end -of -service time indicators. A tactile/audible alarm and a Heads -Up Display. X 14) The HUD shall be powered by the SCBA's single power source. X 15) The HUD shall be integrated in the facepiece X mounted positive pressure breathing regulator. 16) A lightweight, lumbar support style backframe and harness assembly shall be used to carry the cylinder and valve assembly and the pressure -reducing regulator assembly. X 17) The harness assembly shall include a seat -belt type waist belt attachment. X 18) The harness assembly shall be machine washable to help with exposure reduction. X 19) The harness X assembly shall accommodate a waist belt extension: 20) The shoulder harness shall include reflective material to enhance the visibility of the wearer in low -light conditions. X 21) The shoulder harness shall include an accessory clip for attaching a flashlight. X 22) The shoulder harness shall include a chest strap. x 23) The harness design shall have a regulator keeper for storage of the facepiece mounted regulator. X 24) The SCBA shall incorporate a RIC / UAC fitting to be compliant with 2019 edition of the NFPA 1981 Self -Contained Breathing Apparatus standard. X 25) The PASS device shall be compliant to the NFPA 1982, 2019 Edition Standard on Personal Alert Safety Systems. X 26) Operation of the PASS device shall be initiated with the opening of the valve of the SCBA charged cylinder. X 27) The PASS system shall operate from the single power source of the SCBA. X 2of6 28) The PASS device shall notify the user on the HUD when in alarm status. X 29) The control module shall be located on the user's right shoulder harness. X 30) The control module shall include a mechanical pressure gauge that is automatically turned on by opening the cylinder valve. X 31) The control module shall contain push buttons for user interface. X 32) The SCBA shall have integrated voice amplification. X 33) The SCBA shall be powered by alkaline batteries or one lithium -ion battery. X 34) The system shall have a battery check function that provides an LED indication of the battery status while the SCBA is not pressurized. X 35) Four speciality SCBA shall have an additional hose and connection for attachment to the breathing air system of our aerial platform apparatus. X 36) The additional hose and connection shall be stored on the SCBA harness. X 37) The unit shall be covered by a warranty providing protection against defects in materials and workmanship. X 38) The warranty period shall be for 10 years as long as the SCBA is owned by the original purchaser. X 39) FACEPIECE The facepiece shall be approved for use with multiple respiratory applications. MEETS x DOES NOT MEET EXCEPTION 40) The full facepiece assembly shall be available in three sizes; Small, Medium, and Large. x 41) The full facepiece assembly shall be available with nose cups in three sizes; Small, Medium, and Large. X 3 of 6 42) The head harness shall be availble in a five -strap or four -strap configuration. x 43) The full facepiece assembly shall include a neck strap. x 44) The full facepeice assembly shall be capable of water submersion for cleaning and disinfection. x MEETS DOES NOT EXCEPTION CYLINDERS """ 45) The cylinder shall be manufactured in accordance with DOT specifications with working pressures of 4500 psig. X 46) The cylinder shall be available in a 45 minute and 60 minute, duration based on the NIOSH breathing rate of 40 liters per minute. X 47) The cylinder shall be available in an approved 15-year life design as defined by the DOT Special Permit 14232. X 48) The 60 minute cylinders shall have CGA threaded connection. X 49) Delivered cylinders more than 90 days past their manufacture date will not be accepted. X 50) Each facepiece shall include a fleece lined storage bag. X MEETS RAP D INTERVENTION TEAM KIT DOES NOT MEET EXCEPTION 51) RIT assembly shall include a CGA connection to a 4500 psig 60 minute supply cylinder. X 52) RIT assembly shall include a hose with a RIT fitting to connect to the RIT connection on the SCBA of a trapped firefighter. X SUPPLIED AIR ASSEMBLY MEETS DOES NOT MEET EXCEPTION 4of6 53) The supplied air assembly shall allow the connection of an external air supply. X 54) The supplied air assembly shall include a 10 minute carbon rescue cylinder. X 55) The supplied air assembly shall contain the same facepiece mounted positive pressure breathing regulator as the other SCBA. X MEETS BREATHING AIR COMPRESSOR DOES NOT MEET EXCEPTION 56) X Compressor shall operate to a minimum of 6000 psig at 20 cfm. 57) Compressor shall operate on a 3 phase electrical system. X 58) Bid price shall include installation and intitial startup of the compressor. X X 59) The compressor shall be plumbed into our existing manifold and fill station. X MEETS DOES NOT MEET EXCEPTION BREATHING AIR SYSTEM CASCADE CYLINDERS 60) Cascade cylinders shall be 6000 psi rated DOT cylinders. X X 61) Cascade cylinders shall include valves. X BID PRICING FOR: ITEM QTY Unit Price Total Price SCBA Harness Assembly 40 $ 6,891.66 $ 275,666.40 SCBA Harness Assembly with Aerial Ladder connection 4 $ 7,363.32 $ 29,453.28 4500 PSI 60 minute cylinder 10 $ 1,219.89 $ 12,198.90 SCBA Facepiece (Sizes to be determined at a later date) 81 $ 289.37 $ 23,438.97 SCBA Facepiece bag 81 $ 14.44 $ 1,169.64 SCBA hard case 12 $ 143.18 $ 1,718.16 Spare Rechargeable Batteries 21 $ 176.88 $ 3,714.48 Battery Chargers 9 $ 558.79 $ 5,029.11 Rapid Intervention Team Setup 1 $ 1,237.88 $ 1,237.88 Supplied Air Assembly 4 $ 1,453.08 $ 5,812.32 5of6 Breathing Air Compressor 1 $ 32,807.87 $ 32,807.87 Breathing air cascade cylinders 11 $ 1,263.44 $ 13,897.84 Bid Total Expected date of deliver: 11/30/2021 $ 406,144.85 6of6 MSA — The Safety Company MSA Gi SCBA Limited Warranty and Terms of Sale Express Warranty — MSA - The Safety Company (MSA) warrants MSA G1 SCBA (SCBA) to be free from defects in materials and/or faulty workmanship for a period of fifteen (15) years from the date of sale by MSA. This warranty applies to all components` of the SCBA including all accessories and optional equipment purchased and supplied at the time of the original sale. MSA's obligation under this warranty is limited to the repair or replacement, at MSA's option, of the SCBA or components shown to be defective in either workmanship or materials. No agent, employee or representative of MSA may bind MSA to any affirmation, representation or modification of the warranty concerning the goods sold under this contract. MSA shall be released from all obligations under this warranty in the event that repairs or modifications are made by persons other than its own or authorized service personnel, or if the warranty claim results from accident, alteration, misuse, or abuse. *This warranty expressly excludes the G1 SCBA Integrated Thermal Imaging Camera. For warranty information regarding the G1 SCBA Integrated Thermal Imaging Camera please see the G 1 SCBA Integrated Thermal Imaging Camera Warranty. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTEES, EXPRESSED, IMPLIED, OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN ADDITION, MSA EXPRESSLY DISCLAIMS ANY LIABILITY FOR ECONOMIC, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IN ANY WAY CONNECTED WITH THE SALE OR USE OF MSA PRODUCTS, INCLUDING, BUT NOT LIMITED TO, LOSS OF ANTICIPATED PROFITS. v A�4 4 ISO ,„ :9a01: a CER11F EO v C:, -, o,. yr b P1 a 4111 Rev 0 10162874 ID 0105-176-MC/Aug 2017 AMSA 2015 Printed in U.S.A MSA — The Safety Company 1000 Cranberry Woods Drive Cranberry Township, PA 16066 Phone 724-776-8600 www.MSAFire.com Fire Service Customer Service Center Phone 1.877-MSA-FIRE Fax 1-800.967-0398 MSA Canada Phone 1-800-672-2222 Fax 1-800-967.0393 MSA Mexico Phone 018006727222 Fax 52-44 2227 3943 t.1SA International Phone 724-776-8626 Toll -Free 1.800-672-7777 Fax 724-741-1553 MSA The Safety Company VSA G1 SCBA Product S ecification 2216, 4500 and 5500 psig MSfl The Safety Company I. Approvals 1. Apparatus shall be approved by the National Institute for Occupational Safety and Health (NIOSH), under 42 CFR, Part 84 for chemical, biological, radiological, and nuclear protection (CBRN) with 30-, 45-, 60-minute-rated service life and compliant with all requirements of the National Fire Protection Association's 2018 Edition of NFPA-1981 Standard on Open -Circuit Self -Contained Breathing Apparatus 2. Units equipped with integrated PASS device must meet requirements of NFPA 1982, 2018 edition 3. Units equipped with emergency egress system shall also comply with NFPA 1983 Standard on Fire Service Life Safety Rope and System Components, 2017 Edition; Type: Escape 4. Units equipped with accountability system must meet minimum requirements for FCC part 15 and part 90 II. Specific Requirements Facepiece 1. Facepiece shall have removable inhalation check valve to prevent exhaled air from entering and contaminating regulator (demand valve). 2. Facepiece shall have open port to provide minimal breathing resistance when regulator is not attached 3. Facepiece shall not contain electronic components 4. Facepiece shall provide means to display to user with visual indicators for HUD 5. Facepiece shall have icon for HUD system status indicators 6. Facepiece shall have regulator attachment that does not bear any weight on lens 7. Facepiece shall have effective field of view of 86% and overlapping field of view of 122% without attached component 8. Facepiece shall be available in three sizes in Hycar Rubber (small, medium, large) 9. Facepiece shall have nosecup comprised of silicone rubber and available in three sizes (small, medium, large) 10. Facepiece shall have three head harness options constructed of flame/heat resistant assembly: Kevlar Head Harness 4-pt. adjustable, Kevlar 5-pt. adjustable and rubber 5-pt. adjustable 11. Facepiece shall have universal lens that can be used with all three facepiece sizes, shall be comprised of non -shatter type material and shall be field -replaceable 12. Lens shall be hard -coated on outside and anti -fog coated on inside 13. Facepiece shall have optional flame/heat-resistant fabric or rubber neck strap to carry facepiece in ready position for quick donning 14. Facepiece shall have removable speaking diaphragm with aluminum -coated membrane, suitably protected and located centrally on facepiece for optimal voice projection 15. Facepiece shall have exhalation valve that is to be serviceable without special tools 16. Facepiece shall be capable of water submersion for cleaning and disinfection 17. Facepiece provides RFID chip for optional asset & maintenance tracking 1 WHEN YOU GO IN, WE GO IN WITH YOU. Mask -Mounted Regulator (Demand Valve): Push -to -Connect 1. When doffing regulator, regulator disengagement shall simultaneously stop air flow and release regulator 2. Regulator shall house electronic module that functions as microphone and HUD system 3. Regulator shall be equipped with variable flow bypass 4. Regulator shall not have exposed wiring in order to prevent snags and increase product durability 5. Regulator shall have two cover options: hard cover or purge cover 6. Regulator shall have fewer than 35 parts that are easily replaceable without special tools 7. Regulator shall have two options for air -supply hose: 1) Continuous hose from pressure reducer to regulator 2) Quick -connect hose that terminates on shoulder in front of user 8. Regulator must be equipped with positive protection Tetraplex Shield membrane that covers diaphragm, preventing permeation of CBRN agents 9. Regulator shall have RFID chip for optional asset & maintenance tracking Heads -Up Display (HUD) 1. Heads -Up Display (HUD) System shall be integrated within regulator, eliminating snag hazards and increasing product durability 2. HUD shall be powered from central power system 3. HUD System shall eliminate cross -talk among firefighters 4. HUD System shall be immune to radio frequency interference (RFD and must function properly in close proximity to fire service hand-held radios 5. HUD System shall separate pressure indicators from status indicators: 1) Left: status indicators 2) Right: pressure indicators 6. HUD system shall provide user with remaining cylinder air volume, available in four increments through series of four colored LEDs: 1) Four green lights 76-100%cylindervolume 2) Three green lights 51-75% cylinder volume 3) Two flashing amber lights 36-5046 cylinder volume 4) One flashing red light 0-35 %cylinder volume 7. HUD status indicators shall be icon -based and display battery life warning, PASS alarms, EVACUATE indicator, and secondary alarm indicator 8. HUD shall incorporate photoelectric sensor that senses ambient light conditions, automatically adjusting display to one of multiple pre-programmed light intensities 9. Buddy lights shall be visible from outside of firefighter's facepiece 10. HUD system shall allow user to select from four modes of operation: 1) Continuous pressure mode that shall always have pressure LEDs on 2) Intermittent pressure mode that shall turn on first three increments when reached for 20 seconds 3) Oscillating pressure mode that shall brighten and dim LEDs every 20 seconds 4) Mixed pressure mode that shall turn on first two increments when reached for 20 seconds and last two increments are in continuous mode 11. HUD shall be field -removable and replaceable without use of special took WHEN YOU GO IN, WE GO IN WITH YOU.: 2 Universal Air Connection (UAC) 1. System shall be capable of: 1) Refill within Immediately dangerous to life or health (IDLH) atmospheres 2)Transfilling between two SCBA wearers (connection allows for donation and receipt of air), providing emergency breathing system (EBS) while maintaining NIOSH approvals 3) Quickly refilling (approximately one -minute duration) SCBA cylinder from mobile compressor, cascade system or RIT pack 4) Extending wearer's air supply over longer duration when remote cascade system or other compressed gas source is located within remote area 2. Primary UAC shall be illuminated when supply pressure reaches low Pressure Warning Alarm or can be configured to optional medium pressure warning alarm 3. SCBA shall have secondary options for UAC to be mounted on user's waist 4. Transfilling is possible only with 4500 & 2216 psig Pressure Reducer (First -Stage Regulator) with Primary Low -Pressure Warning Device 1. Pressure reducer shall incorporate downstream valve to ensure fail-safe design when in open position 2, Pressure reducer shall incorporate bell alarm mechanism 3. Bell alarm mechanism shall be an air -actuated, continuously ringing audible warning alarm, automatically operating when supply cylinder air pressure reaches approximately 35% of rated service life 4. Bell alarm mechanism shall cover multiple levels of frequencies to cover all hearing levels 5. Bell alarm mechanism shall be user -accessible while wearing SCBA 6. Pressure reducer reduces cylinder pressure to outlet pressure not to exceed 115 psi; outlet pressure must be adjustable 7. Pressure reducer shall have flow capacity of 700 liters per minute at full pressure 8. Pressure reducer shall have two options for cylinder connection type: threaded or quick -connect 9. Quick -connect connection shall not be removable from cylinder while under pressure 10. Pressure reducer shall have one option for cylinder connection location: remote connection 11. Pressure reducer shall he capable of converting from threaded to quick -connect or vice versa 12. Pressure reducer body shall be constructed of high -strength aluminum alloy and anodized with Teflon hard coat to minimize corrosion and wear of internal and external components 13. Pressure reducer shall be sealed system that does not allow moisture to enter valve components 14. Pressure reducer shall have no more than 42 individual regulator replacement parts 15. Pressure reducer shall not require special tools for disassembly 16. Pressure reducer shall have two accessory ports, one medium pressure and one high pressure Cylinders 1. Cylinders with 2216 psig operating pressure must be 30-minute-rated. Cylinders with 4500 psig operating pressure must be available in 30-, 45- and 60-minute durations. Cylinders with 5500 psig operating pressure must be available in 30-, 45-, and 60-minute durations. 2. Cylinders must be available in three operating pressures: 2216, 4500 and 5500 psig 3. Cylinder shall be constructed of deep -drawn, seamless aluminum liner that is fully wound over entire surface (except for thick neck area) with high -strength carbon fiber filaments impregnated with epoxy resin 4. Cylinder shall contain cylinder valve that shall incorporate pressure gauge to indicate cylinder pressure at all times. Pressure gauge face shall be luminescent. Hand wheel shall be placed at 90° angle from cylinder axis. 5. Remote connection available as threaded or quick connect 6. Cylinder valve shall incorporate flow control insert to limit air flow over hand wheel's first half -rotation, minimizing propulsion thrust in event that cylinder is mishandled 7. Cylinder valve shall incorporate CGA thread that can be converted to quick -connect cylinder without special tools 8. Cylinder shall have bracket and boot that can be user -installed and provide positioning and added security of cylinder to backplate. 9. Cylinder shall be available with locking handwheel option. WHEN YOU GO IN, WE GO IN WITH YOU. Emergency Egress Rescue Belt (Optional) 1. In addition to meeting NFPA 1983 standard, rescue belt must be NIOSH-certified and NFPA 1981-2018 edition -con ipliant as SCBA component 2. Rescue system shall include Ara -shield pouch, carabiner or Crosby hook with sewn -in connection and F4 Sterling auto -locking descender 3. Rope shall be available with 50-ft. FireTech 32 rope or aramid/nylon blend 4. Rope shall be detachable under user load, with pull -to -release knot at end of rescue rope as safety feature 5. Rope assembly shall have two end -of -rope flags, one at 15 feet and second at 10 feet 6. Rescue system shall have double -action waist belt buckle as safety feature 7. Rescue system shall have web management system for reduced snag hazards 8. Rope assembly shall be available as replacement part 9. Rescue system shall be capable of quickly detaching from SCBA as safety feature PASS Device 1. PASS device shall contain power, control and battery modules 2. Power module shall provide power to all electronic SCBA components from battery module and act as central power system 3. Power module shall act as central command center, distributing all information and data among electronic components 4. Battery module shall be powered by six C-cell batteries or one lithium -ion rechargeable battery 5. PASS device shall design for battery level check and removal of batteries while SCBA remains in jump seat 6. Power module shall be capable of illuminating UAC fitting when supply cylinder reaches 35% of rated service time 7. Control module shall have analog and digital display for added redundancy. Analog gauge must be positioned above digital display as viewed by user 8. Control module shall be equipped with full color graphical display. Display shall be reprogrammable and capable of future integrations. Display's background color coordinates with HUD pressure status, 9. Control module shall automatically provide information to user when placed in upright position. Device can be manually activated by pressuring reset button 10. PASS device shall use single line to connect power and control module 11. Control module shall have two reset buttons that perform same function no matter which button is pressed 12. Control module shall have alarm button to activate full alarm and is to he illuminated 13. PASS device shall be capable of being reprogrammed to fire department standard operating procedures (SOP). Using PC software program, configuration tag can be created and tagged on each device needed. Reprogramming options are as follows: 1) Medium pressure alarm. 2) Pressure drop alarm. 3) Primary temperature alarm. 4) Secondary temperature alarm. 5) Audible low-pressure alarm 14. PASS device shall be equipped with buddy lights on firefighter's front and back and viewable from 360` view; two buddy lights on front of user and four buddy lights in back of user 15. PASS device shall have colored buddy lights: green (pressure above 5096 and no alarms), yellow (pressure between 36 and 5090) or red (below 36% or alarms are active). 16. Power module shall be equipped with dual sound emitters; sound emitters shall perform at minimum 100 dBa in room temperature 17. PASS device shall be capable of storing up to 36 hours of use information in event log form that are generated each time SCBA is pressurized. Event logs must indicate on/off cycles, alarms, alarm reset, and tagging events 18. PASS device shall be capable of storing periodic logs. Periodic logs must indicate cylinder pressure for each SCBA pressurization stored at 30-second intervals 4 19. PASS device's event and periodic logs shall provide ability to download to personal computer for maintenance records or for use in incident investigations 20. PASS device shall be immune to radio frequency interference (RFI) and must function properly in close proximity of fire service hand-held radios 21. PASS device shall have optional time -remaining display. Time remaining function must update calculations every 30 seconds based upon user's previous three minutes of air consumption. Initial calculation will appear after three minutes. Calculations can be made to zero pressure, low pressure alarm or medium pressure alarm 22. PASS device shall employ gasket perimeter seal to provide highest protection level against water ingress, while providing ability to upgrade or repair electronics 23. PASS device shall be capable of electronically storing user's name into memory via ID tag 24. PASS device shall be removable with no more than two screws 25. Control module shall have service mode that provides ability to see number of hours used, connect to PC and firmware versions 26. Control module shall incorporate rubber boot for added protection and is to be replaceable 27. Power and Control Modules shall have RFID chip for optional asset & maintenance tracking Speaker Module 1. Speaker module shall provide amplified speech that removes inhalation breath noise 2. Speaker module shall provide at minimum, 70 dBa output 3. Speaker module shall turn on and off with PASS device 4. Speaker module shall be powered by central power system 5. Speaker module shall be positioned on chest and attached to shoulder straps. 6. Speaker module shall be capable of being mounted on either left or right shoulder strap 7. Speaker module shall easily be attached and removed without special tools 8. Speaker module shall have light to indicate that device is powered on 9. Speaker module shall have on/off button to allow user to manually power off as needed Emergency Escape Breathing Support System 1. As option, emergency escape breathing support system must be accommodated by SCBA 2. System must be available with common SCBA quick -disconnect fitting 3. System shall connect to intermediate pressure side of SCBA, downstream of pressure reducer 4. System shall have both male and female connections 5. System shall have universal (Rectus) fitting Carrier and Harness 1. Shoulder harness shall have separate left and right pads for easier and less costly replacement 2. Shoulder harness shall have retro-reflective markings for better visibility within low light conditions 3. Shoulder harness shall have localized friction pads on shoulders to prevent slippage 4. Shoulder harness shall be available in standard and serviceable tunnel 5. Shoulder harness shall have improved color stability up to 6001F 6. Shoulder harness shall be capable of washing at least 40 times while maintaining color fastness 7. Shoulder harness shall have optional chest strap 8. Harness design shall have Kevlar webbing 9. Shoulder harness shall have accessory attachment point available for facepiece or pouch and can be easily moved from one shoulder strap to the other 10. Shoulder harness shall differentiate pad inside from pad outside by color; pad inside is grey and outside is black WHEN YOU GO IN, WE GO IN WITH YOU. 11. Waist pad shall be available in three options: 1) Basic - bask pad with straps attaching directly to backplate 2) Adjustable swiveling -standard pad attached to metal bracket that has three positions and automatically centers 3) Rescue Belt II System 12. Adjustable swiveling waist pad shall be one -handed operation and can be performed while on user's back 13. Backplate shall be capable of accepting all three waist pad designs 14. Backplate shall have two side handles and one top handle that are accessible with gloved hand. 15. Backplate side handles shall be capable of 500 lbs. of static force 16. Backplate top handle shall be capable of 1000 Ibs. of static force 17. Backplate cylinder band shall be available in metal 18, Waist pad shall be of rigid construction to allow for easy donning and support 19. Waist straps shall be double -pull forward design 20. Harness design shall have regulator keeper for storage that can be attached to waist strap or chest strap 21. Regulator keeper shall allow regulator to be connected at any angle Weight 1. Weight of SCBA shall not exceed 24 lbs. 2. Weight of facepiece (without regulator, with communications) shall not exceed 1.4 Ibs 3. Weight of cylinder and valve assemblies (empty) shall not exceed: Cylinder Type Weight Carbon -wrapped L30 8 lbs. 0 oz. Carbon -wrapped H30-SL 7lbs. 4 oz. Carbon -wrapped H45 9lbs. 7 oz. Carbon -wrapped H45-SL gibs. 10 oz. Carbon -wrapped H60-SL 11 lbs. 12 oz. Asset and Maintenance Tracking Software 1. Should work on both desktop as well as mobile device 2. Must have the ability to track and report on assets including but not limited to SCBA, Facepieces, Cylinders, and Parts 3. Must have the ability to track and report on Maintenance, including but not limited to Work Orders, cylinder fill and which fill station was used, cylinder hydro static testing, SCBA Row tests 4. Must also have the ability to track and report on Fit Tests 5. Must also have the ability to track and report on Purchase Orders 6. Must have the ability to alert the user on any upcoming fit tests, cylinder hydro static testing, and SCBA overhaul that may be needed 7. Information must be stored in a manner that is updated seamlessly and instantly across all devices Power Source 1. All components of the SCBA must be powered from single power source 2. Power source must have the ability to interchange between alkaline and rechargeable without making adaptations to the SCBA itself 3. Alkaline battery must be powered by six C cell batteries 4. Alkaline battery must weigh no more than 11bs. 5oz. 5. Rechargeable battery must weigh no more than 11b. 6, Rechargeable battery must recharge from full discharge in less than 7 hours 7. Rechargeable battery recharge temperature range must fall between 32°F and 104°F. 8. Rechargeable battery will have full charge capabilities for no less than 300 cycles. 9. Rechargeable battery Charger must be a smart charger which will rapid charge, analyze condition, and switch to trickle charge mode when charge is complete 10. Rechargeable battery Charger must have charging indication lights 6 Integrated Thermal Imaging Camera 1. Must have option for thermal imaging camera to be integrated into control module color display 2. Must have 220 x 176 resolution 3. Integrated Thermal Imaging Camera must have option for 5 user selected color palettes available on control module color display 4. Must be powered by central power source 5. Must have 30 hZ refresh rate 6. Thermal Imaging Camera must add no more than 4.2 oz. in additional weight to the SCBA 7. Thermal Imaging Camera must add no more than 1.25" in additional length to the SCBA Upgradeability 1. Must be Bluetooth° enabled 2. Must be able to receive updates to firmware via a Bluetooth` connection 3. Control module must have Bluetooth° icon visible to display connection status 4. Must have the ability to upgrade standard control module to integrated thermal imaging camera control module Our Mission MSA's mission is to see to it that men and women may work in safety and that they, their families and their communities may live in health throughout the world. MSA: WE KNOW WHAT'S AT STAKE. 0105-179-M11C / 10.2019 WHEN YOU GO IN, WE GO IN WITH YOU.