HomeMy WebLinkAbout3579-09/12/1988 ORDINANCE NO. 3579 AN ORDINANCE AMENDING ORDINANCE NO. 2021 , KNOWN AS THE GAS PIPING CODE, OF THE CITY OF WATERLOO, IOWA, BY ADDING ARTICLE V, FOR THERMOPLASTIC USE FOR NATURAL GAS. BE IT ORDAINED BY THE COUNCIL OF THE CITY OF WATERLOO, IOWA, as follows: That Article V, For Thermoplastic Use for Natural Gas, is hereby added to Ordinance No. 2021 , known as the Gas Piping Code, as follows: FOR THERMOPLASTIC USE FOR NATURAL GAS ARTICLE V Section 500 - Pipe Code for Thermoplastic Underground Only The requirements for plastic pipe or tubing for natural gas pipe for underground use shall be governed by this Code for such installation. Plastic pipe or tubing of the following types are approved for outdoor underground fuel lines and are limited to 100 psig maximum pressure Thermoplastic Pipe PE 3408 Type III Grade 3 Class C. Section 501 - Plastic Pipe Plastic pipe or tubing of the following types are approved as pipe for pressures up to 100 psig. Wall thickness and operating temperatures affect these. Buried pipe will be less than 73 degrees Fahrenheit normally while plastic in a riser is limited to the 120 degrees Fahrenheit rating. PRESSURE LIMITS PRESSURE LIMIT, SIZE psig MAXIMUM TEMP. 1/2" CTS 0 . 090 Wall Tubing 100 120 degrees F 100 73 degrees F 1" CTS 0 . 101 Wall Tubing 60 120 degrees F 100 73 degrees F All Other Sizes: SDR-11 60 120 degrees F 100 73 degrees F Plastic tubing of the approved type is only slightly affected by atmospheric temperatures. Plastic tubing will become more flexible than normal in 100 degree temperature. Care shall be taken to prevent stretching. Plastic tubing will become more rigid than normal in freezing temperatures. The tubing will not become brittle or fracture at temperatures well below zero. Care shall be taken to prevent sharp bends which may kink the tubing. The minimum radius of 25 pipe diameters shall be used. See table below for recommended minimum bend radius. Pipe Size Inches Minimum Bend Radius 1/2" CTS 17" 1" CTS 29" 1" IPS 33" 1 1/4" IPS 42" 2" IPS 60" 3" IPS 88" 4" IPS 113" ECG' 9Qc) `}''(% Ordinance No. 3579 Page 2 Section 502 - Plastic Line Each plastic line outside a building must be installed below ground level, except that it may terminate above-ground and outside the buildings, if: 1. The above-ground part of the plastic line is protected against deterioration and external damage by manufactured riser or Schield Pipe. 2. The plastic line is not used to support external loads. 3 . Riser support bracket be used to support each riser. 4. All buried fuel lines will have a valve at the beginning for control of gas in the buried portion of the line as per drawing. 5. For leak surveying purposes and general safety, plastic pipe will not be allowed under buildings, decks, etc. TYPICAL HOUSE TO GARAGE FUEL LINNZ HOUSE GARAGE , Value �� -i�sulatcd Union1! - ' Anadeless Riser . ... .. Support Support•, r i , Bracket Bracket f � yNOTE: IF Min. .ouer '' .�onndition j cf +ail I Fusion l is rocky, : the ditch Locate °' � Plust be s padded Wire -, I:: with sand tit 1" GIS Polyethylene Pipe Copper = Plastic pipe or tubing shall not be used for direct burial in rocky or other abrasive soils which may damage the plastic unless the plastic pipe is padded and covered with soil or sand. When installing pipe through bores, it may be desirable to occasionally use rigid sticks of plastic pipe rather than coils. This may be particularly true in cold weather conditions. When using coiled plastic pipe, care should be taken to inspect for out-of-roundness. Fusions ( sidewall or butt) should not be made to out-of-round sections. Section 503 - Plastic Pipe--Qualifying Persons to Make Joints No person may make a plastic pipe joint unless that person has been qualified under the applicable joining procedure by: 1. Appropriate training or experience in the use of the procedure; and 2. Making a specimen joint from pipe sections joined according to the procedure that passes the inspection and test set forth in the following paragraph. BOOK 2.82 PAGE 2U7 Ordinance No. 3579 Page 3 The specimen joint must be: 1. Visually examined during and after assembly or joining and found to have the same appearance as a joint or photographs of a joint that is acceptable under the procedure; and 2. In the case of a heat fusion: (i) Tested under any one of the test methods listed under state code applicable to the type of joint and material being tested; ( ii) examined by ultrasonic inspection and found not to contain flaws that would cause failure; or (iii) cut into at least 3 longitudinal straps, each of which is: (A) Visually examined and found not to contain voids or discontinuities on the cut surfaces of the joint area; and (B) Deformed by bending, torque or impact, and if failure occurs, it must not initiate in the joint area. (C) A person must be requalified under an applicable procedure, if during any 12-month period that person: ( 1) does not make any joints under that procedure; or ( 2) has 3 joints or 3 percent of the joints made, whichever is greater, under that procedure that are found unacceptable by testing under U.S. Department of Transportation. (D) Each operator shall establish a method to determine that each person making joints in a plastic pipeline in his system is qualified in accordance with this section. Section 504 - Inspection of Joints No person may carry out the inspection of joints in plastic pipes required by U.S. Department of Transportation code unless that person has been qualified by appropriate training or experience in evaluating the acceptability of plastic pipe joints made under the applicable joining procedure. Section 505 - Installation of Plastic Pipe Plastic pipe must be installed below ground level. Plastic pipe must be installed so as to minimize sheer or tensile stresses. Plastic pipe must have an electrically conductive wire #12 copper THW or equal or other means of locating the pipe while it is underground. Section 506 - Pipelines Each segment of a plastic pipeline must be tested in accordance with this section. The test procedure must insure discovery of all potentially hazardous leaks in the segment being tested. The test pressure must be at least 150 percent of the maximum operating pressure of 50 psig, whichever is greater. However, the maximum test pressure may not be more than three times the design pressure of the pipe. The temperature of thermoplastic material must not be more than 100 degrees Fahrenheit during the test. ma 282 PAGE 268 Ordinance No. 3579 Page 4 Section 507 - Testing While Installing Air pressure must be maintained at all times when pipe is being buried. It will be inspected by a City of Waterloo Inspector. INTRODUCED: September 6, 1988 PASSED 1ST CONSIDERATION: September 6 , 1988 PASSED 2ND CONSIDERATION: September 12 , 1988 PASSED 3RD CONSIDERATION: September 12 , 1988 Passed and adopted by the City Council of the City of Waterloo, Iowa, on the 12th day of September, 1988 , and approved by the Mayor on the 14th day of September, 1988 . Bernard L. McK 'nley, Mayor ATTEST: / La P. B rger, ity lerk/Auditor CERTIFICATE I , Larry P. Burger, City Clerk of the City of Waterloo, Iowa, do hereby certify that attached hereto is a true and complete copy of Ordinance No. 3579 , as passed and adopted by the Council of the City of Waterloo, Iowa, on the 12th day of September, 1988 . Witness my hand and seal of office this 14th day of September, 1988 . L rry P. Burger, Clerk/Auditor } isii COMPAa W' +r' PAGED 3964 'BLACK HAWK COUNTY, IOWA:SS Filed for record ,d/�19 e'8 at 10.'3o A. and recorded in Dcok as,a- Page ai6 s O' Recorder Deputy fee4O.pn ahjv b>;CK 2.82 PAGE 269 a ,. STATE OF IOW A, 53 I do solemnly swear that the annexed copy of Legal Black Iiawk Gooney. Ordinance No . 3579 ORDINANCE A notice was published In the Waterloo Qourict a daily newspaper printed in Waterloo. AN ORDINANCE MENDING �. ORDINANCE NO.2021,KNOWN -.+ AS THE GAS PIPING CODE,OF THE CITY OF WATERLOO, Black Hawk County, Iowa once a- IOWA,BYADDINGARTICLEV, in the issue/of ____— FOR THERMOPLASTIC USE FOR NATURAL GAS. commencing On the.BE IT ORDAINED BY THE COUNCIL OF THE CITY OF WATERLOO,IOWA,as follows: September 23rd + 1988 That Article V. For Thermoplastic Use for Natural Gas,Is hereby added to Ordinance No.2021,known as the Gas Piping of said newspaper, and that the annexed rate of Code,as follows: FOR THERMOPLASTIC USE FOR NATURAL GAS advertising is the regular legal rate of said newspaper,and that the following is a correct bill for ARTICLE V Section 500- publishing said notice. i p ,G� t i Pipe Code,for Thermoplastic p g Printer's Bill $ 0 Underground Only The requirements for plastic pipe 3--"--t-s-r--. or tubing_for ryfural gas pipe for w, underground se shall be gov- erned by for sueh in- Plastic pipe or�fubing of the fol- .�� _day- of lowing types are approved for out- Subscribed and sworn to before me this door underground fuel lines and .�R� are limited to 100 psig maximum t;>;, pressure Thermoplastic Pipe PE , /���� X1 , 3408 type 111 Grade 3 Class C. v ,.... A.D., 19 Section 501- ' Plastic Pipe ('1 Plastic pipe or tubing of the fol- \i}J1F� V lowing types are approved as pipe `� �,t.l,l•ax for pressures up to 100 psig.Wall Notary Public thickness and operating temperatures affect these.Burled pipe will be less than 73 degrees Received of Fahrenheit normally .while plastic In a riser Is limited to the 120 degrees Fahrenheit rating. , Dollars the sum of in full for publication of the above notice.