Loading...
HomeMy WebLinkAbout300 W 4TH O F W A 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE -fi 01/14/2026 02/18/2026 2026-00000290 $80.00 o V ,tfttt40D. • lS 7 tt t 7 N� Customer#: 9011 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DOUGHY JOEY'S 715 Mulberry St 300 W 4TH ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION FEE- 300 W 4TH ST- 01/08/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 9011 01/14/2026 02/18/2026 2026-00000290 $80.00 Less Prepayment $0.00 Total Due—► $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. �,Ew,, Waterloo Fire Rescue o t. ,'k Inspection Report 425 E.3rd Street Doughy Joey's-300 W 4th ST,BLDG 300 W 4th St,Waterloo 50701 Q✓ Pt) INSPECTION DETAILS fib! Inspection Da:a Inspection Type Inspection Number 0110812026 Annual Inspection(1Yr) 16953 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 51 13 ® 11 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0112912026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0110812026 @ 12:58 •$80 annual inspection fee BRAD BALDWIN-01/0812026 @ 15:01 Noted during 118/26 inspection-Employee coats hanging from above kitchen electric panel.Maintain panels easily accessible and visible for fire fighters access in case of emergency. BRAD BALDWIN-01/08/2026 @ 15:06 Corrected during 118126 inspection:(1)Removed obstruction blocking access to fire extinguisher in dishwashing area.(2)Removed storage within 18" below sprinkler head in upper level storage closet.(3)Removed bar mini fridge from extension cord,plugged to wall outlet. BRAD BALDWIN-01/08/2026 @ 15:14 Christmas lights throughout building approved for temporary(90 days)usage. BRAD BALDWIN-01/08/2026 @ 15:18 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-01/0812026 @ 15:18 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-01/0812026 @ 15:18 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.****"Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature GENERATED ON 1/8R6,3:32 PM 1 OF 10 No signature Report completed post inspection Andrew Howe Date: CHECKLISTS Fire Alarm System Code Description Fail Chapter 14-Inspection,testing,and maintenance Fire alarm system tested at least annually by licensed Location:Fire alarm contractor Comments:Fire alarm inspection due 1128/26.Contractor shall upload report to Compliance Engine with any deficiencies corrected. Fire Sprinkler System Status cd- Description Fail 903.3.3-Obstructed locations. OAutomatic sprinklers shall be installed with regard to Location:Near dishwasher obstructions that will delay activation or obstruct the water Comments:Remove dust build-up an sprinkler heads and guards. distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON 1/8/26,3:32 PM 2 OF 10 Fire Service Features st_u< Code, Description Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:Sprinkler riser room protection system equipment to permit immediate safe Comments:Remove all storage from room,maintain clear access to operation and maintenance of such equipment.Storage,trash fire protection services at all times. and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. �11 F 1t �- 3 OF 10 GENERATED ON 1/8/26,3:32 PM Additional Codes s_.-.. c.cde Description Fail 5303.5.3-Securing compressed gas containers,cylinders and tanks. Location:Kitchen tanks near electric panel Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. -,- 1 i „.„,,....-V„...„, ', mks i , 4. GENERATED ON 1/8/26.3:32 PM 4 OF 10 Fail 606.1-General. Commercial kitchen exhaust hoods shall comply with the Location:Kitchen fryers requirements of the International Mechanical Code. Comments:Move fryers to be 6 inches inside of outer edge of hood exhaust system to avoid flame roll out. • 44 lc J: GENERATED ON 1/8/26,3:32 PM 5 OF 10 Electrical Safety Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Kitchen microwave Identified electrical hazards shall be abated.Identified Comments:Replace appliance or cord damaged exposing wires. hazardous electrical conditions in permanent wiring shall be Replacing cord shall be provided by licensed electrician,retain copy brought to the attention of the responsible code official. of receipt of work completed. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 1 Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Main level bathroom hallway. prohibited.Approved covers shall be provided for all switch Comments:Provide missing outlet covers(2). and electrical outlet boxes. GENERATED ON 1/8/26,3:32 PM 6 OF 10 Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Sprinkler riser room equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Comments:Remove all storage from room,maintain clear access to less,and Section 110.33 of NFPA 70 for electrical equipment panels at all times. rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). \......)f )\ l'' ', i' 'A , 1;000f,rr4..ev:0021_ 1 — �' E ., , , ,a,.. -1 , ik,, il yv 3 Y4 yK L V.\ \ \ ; -S , J I 3, B • t' w. ., Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Upper level office for permanent wiring and shall be listed and labeled in Comments:Remove POS system flexible cord from above drop accordance with UL 817.Extension cords and flexible ceiling. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 1/8/26,3:32 PM 7 OF 10 Commercial Cooking Hood Suppression System Sa-,, Des,J .,-,, Fail 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust appurtenances shall be cleaned at intervals as required by Comments:Exhaust cleaning due 1128/26.Provide cleaning and Sections 606.3.3.1 through 606.3.3.3. report to be uploaded to Compliance Engine with any deficiencies corrected. Fail 606.3.3.2-Grease accumulation. If during the inspection it is found that hoods,grease-removal Location:Kitchen fryers cabinet,cooktop,floor under cooking devices,fans,ducts or other appurtenances have an equipment,wall and gas lines behind equipment. accumulation of grease,such components shall be cleaned in Comments:Clean build-up of grease,hood exhaust not engineered to accordance with ANSIIIKECA C1O. provide coverage of grease accumulation. re __ , Mr-11111111r7, • ', ; ' °^ k F ,-- tom:. , , I , V:____ ___ t c , GENERATED ON 1/8/26,3:32 PM 8 OF 10 Fi'e'Resistant Construction Maintenance Status Curie Description Fail 704.1-Maintaining protection. U Where required when the building was originally constructed, Location:Main level hallway near Sprinkler Riser Room materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer&#039;s installation instructions. Fail 705.2.4-Door operation. USwinging fire doors shall close from the full-open position Location:Sprinkler riser room and latch automatically. Comments:Remove items holding door open.Fire rated door shall self close and latch. f],i itil 1 1 y s�. l t', 11 F t V sik �r /w' s ort `�'-- `y GENERATED ON 1/8/26,3:32 PM 9 OF 10 I) Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA 580.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 1/8/26.3:32 PM 10 OF 10