Loading...
HomeMy WebLinkAbout250 ANSBOROUGH OF WA TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE "P< 01/14/2026 02/18/2026 2026-00000293 $235.00 ,/f •6 O s7t1I7�� Customer#: 24040 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HIPPODROME AUDITORIUM 715 Mulberry St 250 ANSBOROUGH AVE WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION FEE-250 ANSBOROUGH- 01/12/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 50,000 $225.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24040 01/14/2026 02/18/2026 2026-00000293 $235.00 Less Prepayment $0.00 Total Due--► $235.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Hippodrome Auditorium-250 Ansborough AVE,BLDG 257 Ansborough Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0111212026 Annual Inspection(1Yr) 16658 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION � 54 �; 18 ® 10 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 02/0612026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-01113/2026 @ 11:36 $325 annual inspection fee BRAD BALDWIN-01/13/2026 @ 12:12 Inspector not granted access to managers office,ticket office,and cash room today. BRAD BALDWIN-01113/2026 @ 12:31 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-01113/2026 @ 12:31 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-01113/2026 @ 12:31 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-01114/2026 @ 08:50 •Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date.Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature No signature Report completedeelpost stinspection GENERATED ON 1/14/26,8:53 AM 1 OF 10 Mark Little-2025 Date: BRAD BALDWIN 01/14/2026 CHECKLISTS Means of Egress Status Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open doors. Location:NE green exit doors(2nd from left door) The force for pushing or pulling open interior swinging Comments:Repair or replace door that failed to open today(top latch egress doors,other than fire doors,shall not exceed 5 not operating). pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:East box office continuously maintained free from obstructions or Comments:Remove furniture from egress path of exit. impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. IY rr tii tii a GENERATED ON 1/14/26,8:53 AM 2 OF 10 Emergency Equipment Stat`s Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:High bay emergency egress lights illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Provide documentation of testing and repairs completed if necessary of all high bay egress lights in building.Report shall be signed and dated and emailed to inspector. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:NW men's bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light that failed to illuminate during test. Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Exit signs in Section 1013.6.3.The system shall be capable of powering Comments:Provide documentation of testing and repairs completed the required load for a duration of not less than 90 minutes. if necessary of all high bay exit lights in building.Report shall be signed and dated and emailed to inspector. Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Lobby men's bathroom in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign that failed to illuminate during the required load for a duration of not less than 90 minutes. test. Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Main lobby exit(south)doors in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign that failed to illuminate during the required load for a duration of not less than 90 minutes. test. GENERATED ON 1/14/26,8:53 AM 3 OF 10 Fire Sprinkler System Sta':s, Cede Description Fail 4.9-Support of nonsprinkler system components Sprinkler system components shall not be used to support Location:Dressing rooms 3&4 non-sprinkler system components unless expressly permitted Comments:Remove wiring used for curtains in shower from by NFPA 13. sprinkler piping. • Fail 4.9-Support of nonsprinkler system components Sprinkler system components shall not be used to support Location:Dressing room 5&6 non-sprinkler system components unless expressly permitted Comments:Remove light and cord supported by sprinkler pipe. by NFPA 13. • Fail 4.9-Support of nonsprinkler system components Sprinkler system components shall not be used to support Location:Dressing rooms 5&6 non-sprinkler system components unless expressly permitted Comments:Remove wiring used for curtains in shower from by NFPA 13. sprinkler piping. 4 OF 10 GENERATED ON 1/14/26,8:53 AM Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Woo store obstructions that will delay activation or obstruct the water Comments:Remove tape from escutcheon ring. distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. ({- 3 GENERATED ON 1/14/26,8:53 AM 5 OF 10 Electrical Safety Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Woo Store(SE wall) Identified electrical hazards shall be abated.Identified Comments:Replace damaged outlet hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. GENERATED ON 1/14/26,8:53 AM 6 OF 10 Fail 603.2•Abatement of unsafe conditions and electrical hazards. Location:West concession Identified electrical hazards shall be abated.Identified Comments:Replace damaged outlet below counter hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. V. �. • Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Exterior outlet above"arcade area"entrance Identified electrical hazards shall be abated.Identified Comments:Replace damaged outlet. hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. GENERATED ON 1/14/26,8:53 AM 7 OF 10 Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Woo store(SE wall) prohibited.Approved covers shall be provided for all switch Comments:Replace missing outlet cover and electrical outlet boxes. 14 .g tq 1i r • GENERATED ON 1/14/26,8:53 AM 8 OF 10 Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Hawkers storage equipment shall be provided in accordance with Section Comments:Remove storage from within 36"in front of panel, 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or maintain clear access to panel at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). - _. , t- l 'ta. _ y !'l J. 4 Fail 603.9.4-Prohibited areas. Portable,electric space heaters shall not be operated within 3 Location:Maintenance area feet(914 mm)of any combustible materials.Portable,electric Comments:Provide documentation of proper commercial listing and space heaters shall be operated only in locations for which label of heater or remove from usage. they are listed. Additional Codes Status Code Description Fail 912.7-Inspection,testing and maintenance. L� Fire department connections shall be periodically inspected, Location:Private hydrants tested and maintained in accordance with NFPA 25.Records Comments:Provide report of inspection with any deficiencies of inspection,testing and maintenance shall be maintained. corrected of all private hydrants on property.Contractor shall upload reports to Compliance Engine,currently 251 days past due as of 1113126. GENERATED ON 1/14/26,8:53 AM 9 OF 10 '® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $235A0 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 1/14/26,8:53 AM 10 OF 10