Loading...
HomeMy WebLinkAbout126 E RIDGEWAY F W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE O • `��o 01/14/2026 02/18/2026 2026-00000289 $80.00 AC o 4S VON Customer#: 24566 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable La Cava 715 Mulberry St 126 E RIDGEWAY WATERLOO, IA 50703 SUITE A WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION FEE- 126 E RIDGEWAY -01/06/2025 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24566 01/14/2026 02/18/2026 2026-00000289 $80.00 Less Prepayment $0.00 Total Due—+ $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue 401 Inspection Report 425 E.3rd Street La Cava-126 E Ridgeway AVE,BLDG 126 E Ridgeway Ave-STE Suite A,Waterl IA 50702 011/e5 S INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 01106/2026 Annual Inspection(1Yr) 14351 Lead Inspector Shift Station Unit BRAD BALDWIN NIA N/A NIA Other Inspectors N/A SUMMARY OF INSPECTION 0 36 0 23 0 24 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 02/04/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-01106/2026 @ 12:59 •$80 annual inspection fee BRAD BALDWIN-01107/2026 @ 07:15 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-0110712026 @ 07:16 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-01107/2026 @ 07:16 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-01112/2026 @ 08:15 Per City Building Official Greg Ahlhelm,per occupancy,exit sign in kitchen shall be removed by properly capping wires and contain in box with cover. BRAD BALDWIN-01/12/2026 @ 08:17 Exit review 2025 SIGNATURES Contact signature Inspector signature No signature Report completedeelpost stinspection GENERATED ON 1/12/26,8:18 AM 1 OF 13 Stephanie Valdivia Date: __— BRAD BALDWIN 01112/2026 CHECKLISTS Means of Egress c a-„; Cc'-',. Description Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:"Employee area"next to bathrooms continuously maintained free from obstructions or Comments:Exit path obstructed,options to correct are as follows: impediments to full instant use in the case of fire or other (1)Per City Building Official Greg Ahlhelm,exit sign may be removed emergency where the building area served by the means of by properly capping wires and containing in covered box.(2)Remove egress is occupied.An exit or exit passageway shall not be storage from corridor. used for any purpose that interferes with a means of egress. n. , mot c General Housekeeping Status Code Description Fail 305.1-Clearance from ignition sources. Clearance between ignition sources,such as luminaires, Location:Water heater heaters,flame-producing devices and combustible materials, Comments:Storage shall be removed within 36"of water heater. shall be maintained in an approved manner. Maintain clearance at all times. Fail 315.3.1-Ceiling clearance. Storage shall be maintained 2 feet(610 mm)or more below Location:"Employee area"next to bathrooms and office. the ceiling in nonsprinklered areas of buildings or not less Comments:Remove storage from within 24"from ceiling. than 18 inches(457 mm)below sprinkler head deflectors in sprinklered areas of buildings.Exceptions:1.The 2-foot(610 mm)ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings.2.The 18-inch(457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1,903.3.1.2 or 903.3.1.3. GENERATED ON 1/12/26,8:18 AM 2 OF 13 Fire Service Features Statue Code Dese iption Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:Kitchen protection system equipment to permit immediate safe Comments:Obstruction to hood suppression pull station and Class operation and maintenance of such equipment.Storage,trash K fire extinguisher(shelf)shall be relocated. and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. I, ,-. kilt 1 44T,04'' PP ,'' I, AI " ':sa.` t• 4i air . . . „. , .„, 4„ II. . t ,idi . .,- - .-- .., t.. .. GENERATED ON 1/12/26,8:18 AM 3 OF 13 Electrical Safety _,...,ice Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Above bar prohibited.Approved covers shall be provided for all switch Comments:Open wire connection shall be corrected by licensed and electrical outlet boxes. electrician.Copy of receipt of repairs completed shall be kept and provided to inspector. • ...., ,:-..; / .‘,#'...::-.7'77.,-.../1111Fr Fail 603.5-Relocatable power taps and current taps.Multiplug adapters. Location:Hostess stand Multiplug adapters,such as cube adapters,unfused plug Comments:Remove green multi plug adapter.Would approve to strips or any other device not complying with NFPA 70 shall replace with properly supported power strip with manual reset for be prohibited.The construction and use of current taps and light duty electric only. relocatable taps shall be in accordance with NFPA 70 and this code. Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Electric panel ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip below panel shall be properly mounted to to environmental or physical damage. wall to avoid hanging by wires. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Front window by main exit for permanent wiring and shall be listed and labeled in Comments:Remove brown extension cord to Bluetooth speaker, accordance with UL 817.Extension cords and flexible extension cord not allowed for permanent,everyday usage.Would cordsshall not be affixed to structures,extended through approve to replace with properly supported power strip with manual walls,ceilings or floors,or under doors or floor coverings, reset for light duty electric only. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 1/12/26,8:18 AM 4 OF 13 Fail 603.6 - Extension cords. , 0 Extension cords and flexible cordsshall not be a substitute Location: Hostess stand for permanent wiring and shall be listed and labeled in Comments: Remove orange extension cord to stand, extension cord accordance with UL 817. Extension cords and flexible not allowed for permanent, everyday usage. Would approve to cordsshall not be affixed to structures, extended through replace with properly supported power strip with manual reset for walls, ceilings or floors, or under doors or floor coverings, light duty electric only. nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. k,,. -4 t'',,, ' ::- :\4142. ... .... IN: ' ' '''''r ' '''''''.; ( N 1 ' 1‘ ' GENERATED ON 1/12/26, 8:18 AM 5 OF 13 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Bar for permanent wiring and shall be listed and labeled in Comments:Remove extension cord,extension cord not allowed for accordance with UL 817.Extension cords and flexible permanent,everyday usage.Would approve to replace with properly cordsshall not be affixed to structures,extended through supported power strip with manual reset for light duty electric only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. T GENERATED ON 1/12/26,8:18 AM 6 OF 13 Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Bar for permanent wiring and shall be listed and labeled in Comments:Remove extension cord to pump,extension cord not accordance with UL 817.Extension cords and flexible allowed for permanent,everyday usage.Relocate pump to plug to cordsshall not be affixed to structures,extended through permanent wall outlet or provide new outlet by licensed electrical walls,ceilings or floors,or under doors or floor coverings, contractor with permit and inspection. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. y4 1 t : rit�1 Ir f - . c',.. —t s'',1 ' iv - -..., '-• Fail 603.6-Extension cords. l^J Extension cords and flexible cordsshall not be a substitute Location:Bar freezer for permanent wiring and shall be listed and labeled in Comments:Remove freezer from extension cord.Appliance shall pug accordance with UL 817.Extension cords and flexible directly to wall outlet.Adding outlet would require licensed electrical cordsshall not be affixed to structures,extended through contractor obtaining permit and inspection. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 1/12/26,8:18 AM 7 OF 13 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Kitchen(chest freezer&Pepsi fridge) for permanent wiring and shall be listed and labeled in Comments:Remove appliances from extension cord.Appliances accordance with UL 817.Extension cords and flexible shall be plugged directly to wall outlets.Adding outlet would require cordsshall not be affixed to structures,extended through licensed electrical contractor obtaining permit and inspection. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. I A 4 4g y.. U _� y _.Pr A 1 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Kitchen(vegetable cooler&microwave) for permanent wiring and shall be listed and labeled in Comments:Remove appliances from multi-plug extension cord. accordance with UL 817.Extension cords and flexible Appliances shall be plugged directly to wall outlets.Adding outlet cordsshall not be affixed to structures,extended through would require licensed electrical contractor obtaining permit and walls,ceilings or floors,or under doors or floor coverings, inspection. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 1/12/26,8:18 AM 8 OF 13 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Bar(chip warmer&beer cooler) for permanent wiring and shall be listed and labeled in Comments:Remove green extension cord and multi-plug adapter accordance with UL 817.Extension cords and flexible from appliance cords.Appliances shall be plugged directly to wall cordsshall not be affixed to structures,extended through outlets.Adding outlet would require licensed electrical contractor walls,ceilings or floors,or under doors or floor coverings, obtaining permit and inspection. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. ql (4' Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Employee area office for permanent wiring and shall be listed and labeled in Comments:Remove white/red extension cord running through accordance with UL 817.Extension cords and flexible doorway to avoid pinching or damaging of cord.Extension cord cordsshall not be affixed to structures,extended through allowed for temporary use only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 1/12/26,8:18 AM 9 OF 13 Additional Codes St<.�tr Code Description Fail 606.1-General. Commercial kitchen exhaust hoods shall comply with the Location:Kitchen single range requirements of the International Mechanical Code. Comments:Kitchen cooking equipment shall be within 6"inside coverage of the hood.Relocate burner to properly fit under hood. • • fr 1 i Commercial Cooking Hood Suppression System Cod;- Description Fail 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust appurtenances shall be cleaned at intervals as required by Comments:Exhaust system cleaning due 1117/26.Provide cleaning Sections 606.3.3.1 through 606.3.3.3. and report to be uploaded to Compliance Engine with any deficiencies corrected. Fail 606.3.3.1-Inspection. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood suppression system appurtenances shall be inspected at intervals specified in Comments:Hood suppression system due for service 1/16/26. Table 606.3.3.1 or as approved by the fire code official. Provide suppression system inspection report with any deficiencies Inspections shall be completed by qualified individuals. corrected.Contractor must upload report to Compliance Engine. GENERATED ON 1/12/26,8:18 AM 10 OF 13 Portable Fire Extingusihers Scat Cod Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Comments:Provide annual service to all fire extinguishers,currently maintained in accordance with this section and NFPA 10. due January 2026. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.6-Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or Location:Front exit obscured from view.In rooms or areas in which visual Comments:Remove or relocate obstruction(Christmas tree)to fire obstruction cannot be completely avoided,means shall be extinguisher. provided to indicate the locations of extinguishers. • fix. t R - .r.•. vr' GENERATED ON 1/12/26,8:18 AM 11 OF 13 Fail 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets, Location:Bar near slushie machine shall be installed on the hangers or brackets supplied. Comments:Annually serviced fire extinguisher shall be hung on wall Hangers or brackets shall be securely anchored to the bracket in required location. mounting surface in accordance with the manufacturer's installation instructions. L S■ 1 I 4 Fail 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets, Location:Near water heater shall be installed on the hangers or brackets supplied. Comments:Fire extinguisher shall be annually serviced and installed Hangers or brackets shall be securely anchored to the in required location on wall bracket at all times.Currently sitting on mounting surface in accordance with the manufacturer's ground. installation instructions. GENERATED ON 1/12/26,8:18 AM 12 OF 13 Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 1/12/26,8:18 AM