Loading...
HomeMy WebLinkAbout1615 BISHOP O W A PF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 430 01/14/2026 02/18/2026 2026-00000288 $80.00 • ....... S Ivi7N� Customer#: 24892 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IOWA CONVENIENCE AND PETRO LLC 715 Mulberry St 1615 BISHOP AVE WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1615 BISHOP - 01/07/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24892 01/14/2026 02/18/2026 2026-00000288 $80.00 Less Prepayment $0.00 Total Due-p $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. aatortz, ' •• ire Rescue � ///� }r Inspection Report t • Y/v �;5�0 /1V6 425 E.3rd street UNI Mart-1615 Bishop AVE,BLDG 1615 Bishop Ave,Waterloo IA 50707 70 3 rt INSPECTION DETAILS / `' ?("1. Inspection Date Inspection Type Inspection Numbcr 01107/2026 Annual Inspection(1Yr) 16354 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION � 44 08 025 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 01130/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-01/09/2026 @ 14:34 Gas pump 91 out of service today 119/26. BRAD BALDWIN-01109/2026 @ 14:37 •$80 annual inspection fee BRAD BALDWIN-01/09/2026 @ 14:37 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(OS)-Cell:319-230-1224 BRAD BALDWIN-01109/2026 @ 14:37 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0110912026 @ 14:37 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 am.-4:00 p.m."•`••Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature p Report completed post inspection Muhammad Samar Date: BRAD BALDWIN 0110912026 CHECKLISTS GENERATED ON 1/926,2:40 PM 1 OF 7 Additional Codes Status Code Description Fail 102.4- Application of building code. OThe design and construction of new structures shall comply Location: Back storage above walk-in cooler with the International Building Code , and any alterations, Comments: Licensed plumbing contractor shall obtain permit and additions, changes in use or changes in structures required inspection of water heater installed. by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 1 4j ..opr-.«..........:, • • w.1 �'k • • r d t 4 Fail 5003.5 - Hazard identification signs. Unless otherwise exempted by the fire code official, visible Location: Outdoor propane cabinet hazard identification signs as specified in NFPA 704 for the Comments: Replace missing hazard identification signage. specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. GENERATED ON 1/9/26, 2:40 PM 2 OF 7 Electrical Safety S;d!b"' Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Cabinet outlet under microwave Identified electrical hazards shall be abated.Identified Comments:Replace damaged outlet. hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 44 It GENERATED ON 1/9/26,2:40 PM 3 OF 7 Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Kitchen,below food openings Identified electrical hazards shall be abated.Identified Comments:Remove(2)cord ground prongs broke off in outlet. hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. • GENERATED ON 1/9/26,2:40 PM 4 OF 7 Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Back storage room equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or Comments:Remove storage from within 36"in front of electric less,and Section 110.33 of NFPA 70 for electrical equipment panels,maintain clearance at all times. rated over 1,000 volts,The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). • dItEri iigi+ ij F 1, ti. GENERATED ON 1/9/26,2:40 PM 5 OF 7 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Storage behind kitchen for permanent wiring and shall be listed and labeled in Comments:Remove black cord from above concealed area(drop accordance with UL 817.Extension cords and flexible ceiling). cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. • . 1'. e Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Kitchen for permanent wiring and shall be listed and labeled in Comments:Remove white multi-plug cord to TV,would approve to accordance with UL 817.Extension cords and flexible replace with properly mounted power strip with manual reset. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Portable Fire Extingusihers 5 vus cc.4, Description Fail 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets, Location:Kitchen shall be installed on the hangers or brackets supplied. Comments:Class K extinguisher shall be properly mounted on wall Hangers or brackets shall be securely anchored to the bracket,currently sitting on ground. mounting surface in accordance with the manufacturer's installation instructions. GENERATED ON 1/9/26,2:40 PM 6 OF 7 r'o Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA 7OF7 GENERATED ON 1/9R6,2:40 PM