Loading...
HomeMy WebLinkAbout132 LOBDELLWA e ., iirv�1•. O INVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/14/2026 02/18/2026 2026-00000053 $250.00 Customer #: 24800 DON AND LYNETTE REINHOLDT P.O. BOX 204 POCAHONTAS, IA 50574 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL FIRE INSPECTION - 132 LOBDELL - 01/14/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 3RD $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24800 01/14/2026 02/18/2026 2026-00000053 $250.00 Less Prepayment Total Due --► City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 132 Lobdell RD, Waterloo IA 50701-1102 INSPECTION DETAILS Inspection Date 01/1412026 Lead Inspector BARRY STRATTON Inspection Type Rental Inspection ( REINSPECTION 4tStrb Other Inspectors NIA 425 E. 3rd Street Inspection Number 16444-R7 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION O 0 Passed codes NEXT STEPS L.j 10 Failed codes Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 GENERAL NOTES BARRY STRATTON - 01114/2026 @ 12:48 Reinspection Date 02111/2026 Plumbing details: Several corrections noted during inspection, a licensed plumbing contractor shall obtain proper permits/inspections to correct any deficiencies. Corrections include but may not be limited to: (1) Main floor bathroom sink drain, flexible drainage piping shall be replaced. (2) Water heater installed without permit/inspection. (3) Mechanical room sink drainage/vent piping installed not to plumbing code shall be corrected. (4) Laundry drainage/vent piping installed not to plumbing code shall be corrected. BARRY STRATTON - 01/14/2026 @ 12:48 Electrical details: Several corrections noted during inspection, a licensed electrical contractor shall obtain proper permits/inspections to correct any deficiencies. Corrections include but may not be limited to: (1) Several open electrical boxes noted in basement without covers. Wires not landed in boxes. (2) Lighting fixture noted in basement stoop unfixed, laying on shelf. (3) Electrical serving furnace, water heater & laundry installed without permitslinspections. (4) Outlets/switches missing appropriate covers. (5) main floor SW bedroom, outlet below window failed tester due to "open ground". (6) Loose wiring noted in basement shall be stapled. (7) Service mast tie down cable connected to chain, nailed to wood post shall be corrected. BARRY STRATTON - 01/14/2026 @ 12:48 -Re-inspection date is as posted on the inspection report given, the rental unit's responsible person/s shall reach out prior to set time of that re - inspection. If all corrections are made before the scheduled inspection, you can call to set up an earlier re -inspection. Appropriate notices shall be given to occupants of the units. Owner or owner's agent must be present during inspections. Failure to schedule a time on the date given or failure to keep the inspection will result in a $100 fee. *****Re inspection fees may be assessed for re -inspections. Re -inspection fees start at $50, then $150, and $250 for all subsequent re -inspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspection. BARRY STRATTON - 01/14/2026 @ 12:49 No permits have been obtained for the required corrections noted from previous inspectors reports. BARRY STRATTON - 01/14/2026 @ 12:49 2026 Rental registration is now open to register all rental properties. SIGNATURES Contact signature Inspector signature GENERATED ON 1/14/26, 12:51 PM 1 OF 5 /- (4,L Don Reinholdt 0111412026 CHECKLISTS GENERATED ON 1/14/26, 12:51 PM 2 OF 5 Reinspection Status Cede Fail Fail Fail Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 907.2.11.2 - Groups R-2, R-3, R-4 and 1-1. Single- or multiple -station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of occupant load at all of the following locations: 1.On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2.1n each room used for sleeping purposes. 3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 907.2.11.2 - Groups R-2, R-3, R-4 and 1-1. Single- or multiple -station smoke alarms shall be installed and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of occupant load at all of the following locations: 1.On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 2.In each room used for sleeping purposes. 3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 915.2.1- Dwelling units. Carbon monoxide detection shall be installed in dwelling units outside of each separate sleeping area in the immediate vicinity of the bedrooms. Where a fuel -burning appliance is located within a bedroom or its attached bathroom, carbon monoxide detection shall be installed within the bedroom. R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Description Location: Several electrical deficiencies Comments: See notes for further details Location: Bedroom #1 Comments: Lack of smoke detector in bedroom. Smoke detectors with proper UL listing required installed in accordance to manufactures guidelines in bedrooms and in good working condition Location: Bedroom #2 Comments: Lack of smoke detector in bedroom. Smoke detectors with proper UL listing required installed in accordance to manufactures guidelines in bedrooms and in good working condition Location: Main floor near bedrooms Comments: Smoke/Carbon monoxide detector failed testing. Repairs or replacement of detector shall be made. Location: Basement stairway Comments: 307.1 General. Every exterior and interior flight of stairs having more than four risers shall have a handrail on one side of the stair and every open portion of a stair, landing, balcony, porch, deck, ramp or other walking surface that is more than 30 inches (762 mm) above the floor or grade below shall have guards. Handrails shall be not Tess than 36 inches (762 mm) in height or more than 42 inches (1067 mm) in height measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. Guards shall be not less than 30 inches (762 mm) in height above the floor of the landing, balcony, porch, deck, or ramp or other GENERATED ON 1/14/26, 12:51 PM 3 OF 5 Fail Fail Fail Fail F� Fail R6.C. - Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition? (IPMC 603.1) R6.E. - Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. (IPMC 504.1) R6.E. - Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. (IPMC 504.1) R6.E. - Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. (IPMC 504.1) R6.E. - Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. (IPMC 504.1) Location: Furnace Comments: Furnace installed without permit & inspection shall be corrected. Licensed HVAC contractor shall obtain proper permitslinspections to correct any deficiencies. Location: Main floor bathroom Comments: Shower walls not water -tight shall be corrected. Loose/flaking paint on wall surfaces shall be corrected. Location: Several plumbing issues Comments: See notes for further details. Location: Mechanical room floor drain Comments: Drain cover obstructed shall be cleared to allow flow of drainage. Location: Main floor bathroom toilet Comments: Toilet failed to flush, shall be corrected. GENERATED ON 1/14/26, 12:51 PM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $250.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 1/14/26, 12:51 PM 5 OF 5