Loading...
HomeMy WebLinkAbout132 LOBDELL (2) w A r INVOICE DATE DUE DATE INVOICE# TOTAL DUE 01/14/2026 02/18/2026 2026-00000054 $50.00 lvi 3 l' Customer#: 24800 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DON AND LYNETTE REINHOLDT 715 Mulberry St P.O. BOX 204 WATERLOO, IA 50703 POCAHONTAS, IA 50574 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL FIRE INSPECTION - 132 LOBDELL- 07/02/2025 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24800 01/14/2026 02/18/2026 2026-00000054 $50.00 Less Prepayment $0.00 Total Due -* $50.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. of) p01A L yrA Waterloo Fire Rescue RUM 1' �V Inspection Report p p y� 425 E.3rd Street 132 Lobdell RD,Waterloo IA 50701-1102 0 0 9o,66 INSPECTION DETAILS (36 ) Inspection Date Inspection Type Inspection Number (3657y 07/02/2025 Rental Inspection J REINSPECTION, 16444-R1 Lead Inspector Shift Station Unit BARRY STRATTON N/A N/A N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 0 0 10 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BARRY STRATTON 0810512025 barry.stratton@waterloo-ia.org,3199611280 GENERAL NOTES BRAD BALDWIN-03/2712025 @ 10:13 Plumbing details:Several corrections noted during inspection,a licensed plumbing contractor shall obtain proper permits/inspections to correct any deficiencies.Corrections include but may not be limited to:(1)Main floor bathroom sink drain,flexible drainage piping shall be replaced.(2)Water heater installed without permit/inspection.(3)Mechanical room sink drainage/vent piping installed not to plumbing code shall be corrected.(4)Laundry drainage/vent piping installed not to plumbing code shall be corrected. BRAD BALDWIN-03/2712025 @ 10:13 Electrical details:Several corrections noted during inspection,a licensed electrical contractor shall obtain proper permits/inspections to correct any deficiencies.Corrections include but may not be limited to:(1)Several open electrical boxes noted in basement without covers.Wires not landed in boxes.(2)Lighting fixture noted in basement stoop unfixed,laying on shelf.(3)Electrical serving furnace,water heater&laundry installed without permits/inspections.(4)Outlets/switches missing appropriate covers.(5)main floor SW bedroom,outlet below window failed tester due to"open ground".(6)Loose wiring noted in basement shall be stapled.(7)Service mast tie down cable connected to chain,nailed to wood post shall be corrected. BRAD BALDWIN-03/2712025 @ 10:13 -Property Safety Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-464-5605 BRAD BALDWIN-03/27/2025 @ 10:13 -Re-inspection date is as posted on the inspection report given,the rental unit's responsible person/s shall reach out prior to set time of that re- inspection.If all corrections are made before the scheduled inspection,you can call to set up an earlier re-inspection.Appropriate notices shall be given to occupants of the unit's.Owner or owner's agent must be present during inspections.Failure to schedule a time on the date given or failure to keep the inspection will result in a$100 fee.***"*Re inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150,and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspection. BRAD BALDWIN-03127/2025 @ 10:13 Therese(tenant&relative of owner)will be representative for owner during re-inspection.641-751-1486 SIGNATURES Contact signature Inspector signature GENERATED ON 7/2/25,11:27 AM 1 OF 5 --. "--.7 Don Reinholdt 07102/2025 CHECKLISTS GENERATED ON 7/2/25,11:27 AM 2 OF 5 Reinspection status Code Description Fail 603.2-Abatement of unsafe conditions and electrical 0 hazards. Location:Several electrical deficiencies Identified electrical hazards shall be abated.Identified Comments:See notes for further details hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Additional comments:No permits obtained. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 907.2.11.2-Groups R-2,R-3,R-4 and 1-1. Single-or multiple-station smoke alarms shall be installed Location:Bedroom#1 and maintained in Groups R-2,R-3,R-4 and 1-1 regardless of Comments:Lack of smoke detector in bedroom.Smoke detectors occupant load at all of the following locations:l.On the with proper UL listing required installed in accordance to ceiling or wall outside of each separate sleeping area in the manufactures guidelines in bedrooms and in good working condition immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. Fail 907.2.11.2-Groups R-2,R-3,R-4 and 1-1. 0 Single-or multiple-station smoke alarms shall be installed Location:Bedroom#2 and maintained in Groups R-2,R-3,R-4 and 1-1 regardless of Comments:Lack of smoke detector in bedroom.Smoke detectors occupant load at all of the following locations:1.On the with proper UL listing required installed in accordance to ceiling or wall outside of each separate sleeping area in the manufactures guidelines in bedrooms and in good working condition immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.ln each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. Fail 915.2.1-Dwelling units. 0 Carbon monoxide detection shall be installed in dwelling Location:Main floor near bedrooms units outside of each separate sleeping area in the immediate Comments:Smoke/Carbon monoxide detector failed testing.Repairs vicinity of the bedrooms.Where a fuel-burning appliance is or replacement of detector shall be made. located within a bedroom or its attached bathroom,carbon monoxide detection shall be installed within the bedroom. Fail R6-Interior Structure 0 Has the interior of the structure and equipment inside been Location:Basement stairway maintained in good repair,structurally sound,and in a Comments:307.1 General.Every exterior and interior flight of stairs sanitary condition?(IPMC 305) having more than four risers shall have a handrail on one side of the stair and every open portion of a stair,landing,balcony,porch,deck, ramp or other walking surface that is more than 30 inches(762 mm) above the floor or grade below shall have guards.Handrails shall be not less than 36 inches(762 mm)in height or more than 42 inches (1067 mm)in height measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces. Guards shall be not less than 30 inches(762 mm)in height above the floor of the landing,balcony,porch,deck,or ramp or other GENERATED ON 7/2/25,11:27 AM 3 OF 5 Fail R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained Location:Furnace in good working condition?(IPMC 603.1) Comments:Furnace installed without permit&inspection shall be corrected.Licensed HVAC contractor shall obtain proper permits/inspections to correct any deficiencies. Additional comments:No new permits Fail R6.E.-Plumbing System and Fixtures 0 Plumbing fixtures shall be properly installed and maintained Location:Main floor bathroom in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function Comments:Shower walls not water-tight shall be corrected. Loose/flaking paint on wall surfaces shall be corrected. for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition.(IPMC 504.1) Po- ff i dSf Fail R6.E.-Plumbing System and Fixtures 0 Plumbing fixtures shall be properly installed and maintained Location:Several plumbing issues in working order,and shall be kept free from obstructions, Comments:See notes for further details. leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition.(IPMC 504.1) Fail R6.E.-Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained Location:Mechanical room floor drain in working order,and shall be kept free from obstructions, Comments:Drain cover obstructed shall be cleared to allow flow of leaks and defects and be capable of performing the function drainage. for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition.(IPMC 504.1) Fail R6.E.-Plumbing System and Fixtures Cx Plumbing fixtures shall be properly installed and maintained Location:Main floor bathroom toilet in working order,and shall be kept free from obstructions, Comments:Toilet failed to flush,shall be corrected, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition.(IPMC 504.1) GENERATED ON 7/2/25,11:27 AM 4 OF 5 - Statement of Fees FEE Invoice Date inspection Fee Date Paid Amount Paid N/A $50.00 ._. .. _. _ Invoice Number Check Number Transaction Number NIA N/A NIA GENERATED ON 7/2/25, 11:27 AM 5 OF 5