Loading...
HomeMy WebLinkAbout224 SUNNYSIDE AVENUE OF W 4 rF INVOICE DATE DUE DATE INVOICE# TOTAL DUE ' s0 01/21/2026 02/25/2026 2026-00000058 $250.00 u .,f/Iir,.► a bii ..,0 10, ) �s tvt'3‘ Customer#: 24845 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ATTN: KEVIN ADELMUND KVA HOLDINGS,LLC 715 Mulberry St 21517 NEWELL AVENUE WATERLOO; IA 50703 ALLISON, IA 50602 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL FIRE INSPECTION - 224 SUNNYSIDE AVE - 12/16/2025 FOR BILLING INQUIRY: (319)291-4323 Description Total Price 1 REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24845 01/21/2026 02/25/2026 2026-00000058 $250.00 Less Prepayment $0.00 Total Due —* $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. *ate ' Waterloo Fire Rescue rr�� 01* Inspection Report , 11� 425E,3rdStreet KVA Holdings LLC-224 Sunnyside AVE,Waterloo IA 50701-2542 fib ' INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 12/16/2025 Rental Inspection REINSPECTION 17245-R5 Lead Inspector Shift Station Unit BARRY STRATTON N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 0 13 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BARRY STRATTON 01/13/2026 barry.stratton@waterloo-ia.org,3199611280 GENERAL NOTES BARRY STRATTON-12/1612025 @ 12:07 304.10 Stairways,decks,porches and balconies.Every exterior stairway,deck,porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound,in good repair,with proper anchorage and capable of supporting the imposed loads. BARRY STRATTON-12/16/2025 @ 12:07 IPMC 604.3:604.3 Electrical system hazards.Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service,improper fusing,insufficient receptacle and lighting outlets,improper wiring or installation,deterioration or damage,or for similar reasons,the code official shall require the defects to be connected to eliminate the hazard. BARRY STRATTON-12/1612025 @ 12:07 Some corrections have been completed on a re-inspection done today.Continue to make corrections to get rental unit completed. SIGNATURES Contact signature Inspector signature /\/VIV \p, KVA Holdings LLC 12116/2025 BARRY STRATTON 12/16/2025 CHECKLISTS GENERATED ON 1/13/26,3:47 PM 1 OF 3 Reinspection -a. Code Description Fail 1010.2-Door operations. Except as specifically permitted by this section,egress doors Location:Back door shall be readily openable from the egress side without the use of a key or special knowledge or effort. Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Kitchen ceiling needs replaced,walls need drywall where Identified electrical hazards shall be abated.Identified holes are,trim around doors,doors need to open and close(back hazardous electrical conditions in permanent wiring shall be door)lights not working,globes needed on all lights. brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 906.1-Where required. Portable fire extinguishers shall be installed in all of the Location:Need fire extinguisher installed. following locations:1.In new and existing Group A,B,E,F,H, I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.ln Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3.In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use.3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4. Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5.Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1;1-2,Condition 1;and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official.Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Fail 907.2.11-Single-and multiple-station smoke alarms. Listed single-and multiple-station smoke alarms complying Location:Need smoke detectors installed outside bedrooms and in with UL 217 shall be installed in accordance with Sections all bedrooms.Smoke detector needed in basement. 907.2.11.1 through 907.2.11.7 and NFPA 72. V GENERATED ON 1/13/26,3:47 PM 2 OF 3 Fail 915.1-General. Carbon monoxide detection shall be installed in new Location:Need CO detectors in stalled outside bedrooms buildings in accordance with Sections 915.1.1 through 915.6. Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Fail R1-Unsafe Structures Is the structure found to be dangerous to the life,health, Location:Floors,walls,ceilings,basement stairs. property or safety of either the public or occupants of the structure?(IPMC 108.1.1) Fail R2-Unsafe Equipment Was the presence of unsafe equipment noted during the Location:Water heater,kitchen ceiling has water damage from inspection?Equipment may include boilers,heating leaking plumbing.PEX not installed to meet code throughout equipment,elevator,moving stairways,electrical wiring,and property. flammable liquid containers.(IPMC 108.1.2) Fail R5-Exterior Structure Is the exterior of the structure maintained in good repair, Location:Front porch and front steps needs replaced.Need handrail structurally sound and sanitary state?(IPMC 304) replaced on front stairs.Back stairs need replaced and need handrail installed to meet code. Fail R6-Interior Structure Has the interior of the structure and equipment inside been Location:Walls(holes)doors missing trim,holes in floors need maintained in good repair,structurally sound,and in a repaired,handrails to basement needed,electric covers missing, sanitary condition?(IPMC 305) back door needs to open and close,windows need to function and have screens/locks tub missing handle for hot water side.Kitchen cabinets need repaired and doors and drawer fronts in place. Fail R6.A.-Interior Structure-Unsafe Conditions Were any unsafe conditions noted during the interior Location:Electrical issues,plumbing issues,mold,water issues inspection?(IPMC 305.1.1) Fail R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained Location:Water heater missing PT tube. in good working condition?(IPMC 603.1) Fail R6.D.-Receptacles Every habitable space in a dwelling shall contain not less Location:Missing electrical covers than two separate and remote receptacle outlets.Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a GFCI.Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle shall have GFCI protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2) Fail R6.E.-Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained Location:PEX is leaking in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition.(IPMC 504.1) GENERATED ON 1/13/26,3:47 PM 3 OF 3