Loading...
HomeMy WebLinkAbout617 SYCAMORE OF W 4 7. n INVOICE DATE DUE DATE INVOICE# TOTAL DUE 01/21/2026 02/25/2026 2026-00000297 $80.00 u ` fa O .............. )46S4040 1tt0 Customer#: 8735 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SYCAMORE CONVENIENCE 715 Mulberry St 619 SYCAMORE ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 617 SYCAMORE- 01/15/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 8735 01/21/2026 02/25/2026 2026-00000297 $80.00 Less Prepayment $0.00 Total Due -- $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue j,�� Inspection Report C6t) 425 E.3rd Street Sycamore Convienence Store-617 Sycamore ST,BLDG 617 Sycamore St-STE 619 Sycamore,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 01/15/2026 Annual Inspection(1Yr) 16140 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION C 32 8 ® 36 Passed codes c.oci_:s Ni NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 02106/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-01115/2026 @ 15:32 $80 annual inspection fee BRAD BALDWIN-0111512026 @ 15:32 Fire extinguishers due annually serviced March 2025 BRAD BALDWIN-01/1612026 @ 08:16 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-01116/2026 @ 08:16 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-01/16/2026 @ 08:16 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature 1 � Report completed post inspection (Sarah)2025 Date: BRAD BALDWIN 01116/2026 CHECKLISTS 1 OF 6 GENERATED ON 1/16/26,8:18 AM General Housekeeping Li,-:, Descript,en Fail 305.1-Clearance from ignition sources. Clearance between ignition sources,such as luminaires, Location:Basement water heater heaters,flame-producing devices and combustible materials, Comments:Remove storage from within 36"of water heater,maintain shall be maintained in an approved manner. clearance at all times. \ \ tc f i ¢ ' 1� =� ` i 6 Additional Codes � Descrii;=yen Fail 5303.5.3-Securing compressed gas containers,cylinders and tanks. Location:Basement Compressed gas containers,cylinders and tanks shall be Comments:All tanks,empty or full shall be chained up to avoid tip secured to prevent falling caused by contact,vibration or over seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders 1 and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Fail 603.9.1-Listed and labeled. Only listed and labeled portable,electric space heaters shall Location:Behind both liquor and tobacco side register counters. be used. Comments:Provide documentation of listing and labeling of heater for use in commercial space or remove from building. GENERATED ON 1/16/26,8:18 AM 2 OF 6 Electrical Safety i Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Liquor side(back storage) prohibited.Approved covers shall be provided for all switch Comments:Install bulb in open light socket to avoid shock hazard and electrical outlet boxes. l; f I' ({ \ J.:."14411111111111'.' R'e:al34-'''..-' °-:'2' ti i rN�i`o ,,eax `O` , I Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Tobacco side(back storage) prohibited.Approved covers shall be provided for all switch Comments:Provide plug for opening in box and electrical outlet boxes. 1Y • I v 14. y1+'. ,' N m.- \. ' ' e ` r c \ . \ „ti- j:-. 30F6 GENERATED ON 1/16/26,8:18 AM Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Basement equipment shall be provided in accordance with Section Comments:Storage shall be removed within 36"in front of and 30"in 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or width of electrical equipment(both sides of stairs).Clear storage in less,and Section 110.33 of NFPA 70 for electrical equipment direct path of access to electric equipment for firefighters. rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). 'ti I i J; vg kii / . • :4T s # . ,. V jr'- * ii' ......, V ` �, t . �' ' GENERATED ON 1/16/26,8:18 AM 4 OF 6 Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Tobacco side(behind display shelf) connected to a permanently installed receptacle.Exceptions: Comments:Power strip shall be plugged directly to wall outlet, 1.Where approved for use in a Group A occupancy or in a currentlyplugged to brown extension cord.Extension cord shall not meeting room in a Group B occupancy,not more than five p gg be used as permanent wiring. relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. POP o r Portable Fire Extingusihers Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Liquor side near back storage room maintained in accordance with this section and NFPA 10. Comments:Class K extinguisher for old kitchen shall be serviced or Exceptions:1.The distance of travel to reach an extinguisher removed from building. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. SOF6 GENERATED ON 1/16/26,8:18 AM '® Statement of Fees FEE Invoice Date Inspectio Fee Date Paid Amount Paid NIA 880.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 1/16/26,8:18 AM 60F6