Loading...
HomeMy WebLinkAbout205 W. 4TH STREET W 4 T INVOICE DATE DUE DATE INVOICE # TOTAL DUE O Y< F. ,� 3, M '`'v e 01/21/2026 02/25/2026 2026-00000298 $80.00 • •R.,•/rw•• i • • ri • iii 6) 1: Q Customer #: 24382 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable Ariz 715 Mulberry St 205 W 4th Street WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 205 W 4TH ST - 01/15/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE # CHARGES 24382 01/21/2026 02/25/2026 2026-00000298 $80.00 Less Prepayment $0.00 Total Due —+ $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ads sit .„„0 Waterloo Fire Rescue ®� Inspection Report 425 E.3rd Street Ariz Restaurant-205 W 4th ST,BLDG 205 W 4th St,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0111512026 Annual Inspection(1Yr) 19974 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 58 u 13 ® 10 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0211112026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-01116/2026 @ 08:45 •$80 annual inspection fee BRAD BALDWIN-01116/2026 @ 08:45 Fire extinguishers due annually serviced July 2026 BRAD BALDWIN-01116/2026 @ 09:23 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-01/16/2026 @ 09:23 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-0111612026 @ 09:23 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection -BO Aurion Redding Date: _ BRAD BALDWIN 0111612026 CHECKLISTS 1oFa GENERATED ON 1/16/26,9:26 AM Additional Codes Sta'.:i: Code Description Fail 313.1-General. Fueled equipment including,but not limited to,motorcycles, Location:Kitchen storage mopeds,lawn-care equipment,portable generators and Comments:Remove motorcycle from building portable cooking equipment,shall not be stored,operated or repaired within a building.Exceptions:1.Buildings or rooms constructed for such use in accordance with the International Building Code.2.Where allowed by Section 314.3.Storage of equipment utilized for maintenance purposes is allowed in approved locations where the aggregate fuel capacity of the stored equipment does not exceed 10 gallons(38 L)and the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. .sr11111111/1 r • \1 1 Fail 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the Location:Clothes dryer exhaust duct system of a clothes dryer shall be maintained in Comments:Provide documentation of dryer vent cleaning from accordance with the manufacturer&#039;s operating instructions to prevent the accumulation of lint or debris that appliance to exterior of building. prevents the exhaust of air and products of combustion. GENERATED ON 1/16/26.9:26 AM 2 OF 8 Fail 807.2-Combustible decorative materials. In Groups A,B,E,I,M and R-1 and in dormitories in Group R- Location:By old pool exit 2,curtains,draperies,fabric hangings and other similar Comments:Provide documentation of proper fire rating of curtains combustible decorative materials suspended from walls or hanging from Ceiling. ceilings shall comply with Section 807.3 and shall not exceed 10 percent of the specific wall or ceiling area to which such materials are attached.Fixed or movable walls and partitions, paneling,wall pads and crash pads applied structurally or for decoration,acoustical correction,surface insulation or other purposes shall be considered to be interior finish,shall comply with Section 803 and shall not be considered decorative materials or furnishings.Exceptions:1.In auditoriums in Group A,the permissible amount of curtains, draperies,fabric hangings and similar combustible decorative material suspended from walls or ceilings shall not exceed 75 percent of the aggregate wall area where the building is equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1,and where the material is installed in accordance with Section 803.15 of the International Building Code.2.In Group R-2 dormitories, within sleeping units and dwelling units,the permissible amount of curtains,draperies,fabric hangings and similar decorative materials suspended from walls or ceilings shall not exceed 50 percent of the aggregate wall areas where the building is equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1. 3.In Group B and M occupancies,the amount of combustible fabric partitions suspended from the ceiling and not supported by the floor shall comply with Section 807.3 and shall not be limited.4.The 10-percent limit shall not apply to curtains,draperies,fabric hangings and similar combustible decorative materials used as window coverings. Fail 807.2-Combustible decorative materials. In Groups A,B,E,I,M and R-1 and in dormitories in Group R- Location:By pool table 2,curtains,draperies,fabric hangings and other similar Comments:Provide documentation of proper fire rating of curtains combustible decorative materials suspended from walls or hanging from ceiling. ceilings shall comply with Section 807.3 and shall not exceed 10 percent of the specific wall or ceiling area to which such materials are attached.Fixed or movable walls and partitions, paneling,wall pads and crash pads applied structurally or for decoration,acoustical correction,surface insulation or other purposes shall be considered to be interior finish,shall comply with Section 803 and shall not be considered decorative materials or furnishings.Exceptions:1.In auditoriums in Group A,the permissible amount of curtains, draperies,fabric hangings and similar combustible decorative material suspended from walls or ceilings shall not exceed 75 percent of the aggregate wall area where the building is equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1,and where the material is installed in accordance with Section 803.15 of the International Building Code.2.In Group R-2 dormitories, within sleeping units and dwelling units,the permissible amount of curtains,draperies,fabric hangings and similar decorative materials suspended from walls or ceilings shall not exceed 50 percent of the aggregate wall areas where the building is equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1. 3.In Group B and M occupancies,the amount of combustible fabric partitions suspended from the ceiling and not supported by the floor shall comply with Section 807.3 and shall not be limited.4.The 10-percent limit shall not apply to curtains,draperies,fabric hangings and similar combustible decorative materials used as window coverings. TOES GENERATED ON 1/1626.9:26 AM Fire Service Features States Code Description Fail 509.2 - Equipment access. OApproved access shall be provided and maintained for all fire Location: Near office protection system equipment to permit immediate safe Comments: Remove items blocking access to fire alarm pull station operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. • 11111 VIONIMINIIIIII -, _-r- I _ _ 64114 r - *it,. k . ,j,, y }L EI . Iffif 'IIti 4 - Z 1 b ; i .\ t1 114 --'' IA i . GENERATED ON 1/16/26, 9:26 AM 4 OF 8 Electrical Safety slat Cade Description Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Electric panel by laundry appliances equipment shall be provided in accordance with Section Comments:Remove storage below electric panels,maintain 36" 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or clearance at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Fail 603.5-Relocatable power taps and current taps.Multiplug adapters. Location:Between two bars by"Grand Marnier"neon sign Multiplug adapters,such as cube adapters,unfused plug Comments:Remove multi-plug adapter,would approve use of strips or any other device not complying with NFPA 70 shall properly mounted power strip with manual reset for light duty electric be prohibited.The construction and use of current taps and only. relocatable taps shall be in accordance with NFPA 70 and this code. 3:43 ..d tiNI mac.. i i rn I fill'��dt�. 41a a -3 fi 79..011 5 OF 8 GENERATED ON 1/16/26,9:26 AM Fail 603.5-Relocatable power taps and current taps.Multiplug adapters. Location:Kitchen near smoker Multiplug adapters,such as cube adapters,unfused plug Comments:Remove multi-plug adapter,would approve properly strips or any other device not complying with NFPA 70 shall mounted power strip with manual reset for light duty electric only. be prohibited.The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. • -i 4, t ; '* : Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:North side window"Open"sign by bar for permanent wiring and shall be listed and labeled in Comments:Remove multi-plug extension cord to sign,would accordance with UL 817.Extension cords and flexible approve sign plugged to properly mountedpower stripwith manual cordsshall not be affixed to structures,extended through pPp gg p p y reset. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:By"Pure Leaf"beverage fridge for permanent wiring and shall be listed and labeled in Comments:Remove green multi-plug extension cord. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Fireplace for permanent wiring and shall be listed and labeled in Comments:Remove fireplace from extension cord,appliance shall accordance with UL 817.Extension cords and flexible plug directly to wall outlet. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 1/16/26,9:26 AM 6 OF 8 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Kitchen small chest freezer for permanent wiring and shall be listed and labeled in Comments:Remove freezer from extension cord,freezer shall plug accordance with UL 817.Extension cords and flexible directly to wall outlet cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Status Code Deseripticn Fail 606.3.3-Cleaning. OHoods,grease-removal devices,fans,ducts and other Location:Kitchen hood exhaust appurtenances shall be cleaned at intervals as required by Comments:Exhaust system cleaning 146 days past due as of 1116126. Sections 606.3.3.1 through 606.3.3.3. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. GENERATED ON 1/16/26,9:26 AM 7 OF 8 El Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 1/16/26,9:26 AM 8 OF 8