Loading...
HomeMy WebLinkAbout1211 LANGLEY RD APT 8INVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/27/2026 03/03/2026 2026-00000060 $100.00 Customer #: 23944 WATERLOO INVESTMENT GROUP LLC PO BOX 56 Waterloo, IA 50704 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS IPMC RENTAL INSPECTION - 1211 LANGLEY RD APT 8 - 01 /26/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 2ND $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23944 01/27/2026 03/03/2026 2026-00000060 $100.00 Less Prepayment Total Due --> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 262(e -- 6 c oo° I 15 Waterloo Fire Rescue Inspection Report VIA Apt 8 - 1211 Langley RD, BLDG 1211 Langley Rd, Waterloo IA 50702-4263 INSPECTION DETAILS Inspection Date 01/26/2026 Lead Inspector NATE BEUSELING Inspection Type 2015 IPMC Rental Inspection 2 S9 425 E. 3rd Street Other Inspectors Randy Girsch Shift NIA Station NIA Inspection Number 19114-R1 Unit NIA SUMMARY OF INSPECTION 0 0 Passed codes NEXT STEPS C7 9 Failed codes Please direct questions about your Inspection to: NATE BEUSELING nate.beuseling@waterloo-ia.org GENERAL NOTES NATE BEUSELING - 11/26/2025 @ 10:10 Cell: 319-464-5605 Property Safety Inspector - nate.beuseling@waterloo-ia.org - Work: 319-291-4319 (#8) - Reinspection Date 02/25/2026 NATE BEUSELING - 11/26/2025 @ 10:10 Re -inspection date is as posted on the inspection report. The rental unit's responsible person/s shall contact prior to inspection date to set up time of re - inspection. If all corrections are made before scheduled inspection, you can call to set up an earlier re -inspection. Please give the appropriate notices to occupants of the unit's. Owner or owner's agent must be present during the re -inspections. Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a $100.00 fee. Re -inspection fees may be assessed for re -inspections. Re -inspection fees start at $50, then $150, and $250 for all subsequent re -inspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspections. NATE BEUSELING - 11/26/2025 @ 10:10 All structural repairs, water heater replacement, furnace replacement and major electrical repairs require appropriate permits and inspections. NATE BEUSELING - 11/26/2025 @ 10:10 Complaint call for mice infestation on 11/2612025 SIGNATURES Contact signature Inspector signature No signature Person not available for signature MGT Property Management Date: NATE BEUSELING 01/26/2026 CHECKLISTS GENERATED ON 1/26/26, 9:32 AM 1 OF 6 Reinspection Status Code Fail 2015 IPMC 304.13 - Window, skylight and door frames Every window, skylight, door and frame shall be kept in sound condition, good repair and weather tight. Fail 2015 IPMC 304.13.2 - Openable windows Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware Fail 2015 IPMC 304.15 - Doors Exterior doors, door assemblies, operator systems if provided, and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. Fail 2015 IPMC 305.3 - Interior surfaces Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 309.1- Infestation Structures shall be kept free from insect and rodent infestation. Structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health. After pest elimination, proper precautions shall be taken to prevent reinfestation. Description Location: Bedroom 1 on left Comments: Window above bed cracked repair or replace Location: Living room Comments: Right side of window does not latch properly Location: Floor 2 common area Comments: Door on south end of building has broken handle needs replaced and door opens and shuts properly Location: Bathroom Comments: Transition strip in disrepair - secure to ground Location: Unit 8 Comments: Complaint filed tenants state they have mice infestation catching 38 Mice since February, shall seek pest control and take appropriate measures to remove infestation GENERATED ON 1/26/26, 9:32 AM 2 OF 6 Fail Fail 2015 IPMC 505.4 - Water heating facilities Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory, bathtub, shower and laundry facility at a minimum temperature of 110°F (43°C). A gas -burning water heater shall not be located in any bathroom, toilet room, bedroom or other occupied room normally kept closed, unless adequate combustion air is provided. An approved combination temperature and pressure -relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters 2015 IPMC 605.2 - Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding -type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not Tess than one receptacle. Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover for the location. Location: Kitchen Area - Water heater Comments: Water heater not to code, shall gain proper permits and Inspections to close out Location: Living room Comments: Receptacle at front door reads open ground GENERATED ON 1/26/26, 9:32 AM 3 OF 6 Fail 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, 1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Location: Kitchen Comments: Fire extinguisher not tagged properly, current year GENERATED ON 1/26/26, 9:32 AM 4 OF 6 Fail 906.1- Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Location: Floor 2 Common Area Comments: Fire extinguishers not tagged properly- past due on inspection shall replace with properly inspected extinguishers GENERATED ON 1/26/26, 9:32 AM 5 OF 6 ro FEE Statement of Fees Invoice Date Inspection Fee NIA $100.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 1/26/26, 9:32 AM 6 OF 6