Loading...
HomeMy WebLinkAbout210 E TOWER PARK DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/27/2026 03/03/2026 2026-00000312 $600.00 Customer #: 10758 SAM'S CLUB #6514 210 E TOWER PARK DR WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 210 E TOWER PARK DR - 01 /21 /2026 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 100,000 Total Price $600.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 10758 01/27/2026 03/03/2026 2026-00000312 $600.00 Less Prepayment Total Due —+ City of Waterloo $0.00 $600.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. bto l 015t Waterloo Fire Rescue Inspection Report Sam's Club - 210 E Tower Park DR, BLDG 210 E Tower Park Dr, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 01/21/2026 Inspection Type Annual Inspection (1Yr) 425 E. 3rd Street Inspection Number 18892 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 058 Passed codes NEXT STEPS 0 14 Failed codes 7 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 01/2112026 @ 15:37 $600 annual inspection fee BRAD BALDWIN - 01/22/2026 @ 08:02 Fire extinguishers due annually serviced in March 2026 BRAD BALDWIN - 01/22/2026 @ 08:26 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 01/22/2026 @ 08:26 Reinspection Date 02112/2026 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 01/22/2026 @ 08:26 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 01122/2026 @ 08:27 • Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 1/22/26, 8:29 AM 1 OF 8 Mike Ahmann - Fresh Manager (2026) Date: BRAD BALDWIN 01/22/2026 CHECKLISTS Means of Egress Status Cods Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Emergency Equipment Status Code Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Description Location: Front maintenance closet Comments: Exit door to exterior failed to open today. Repair or replace door, replacing door requires obtaining permit and inspections. Description Location: Emergency egress lighting Comments: Provide documentation of testing all egress lighting in building including repairs made to maintain working properly, documentation shall include signature and date of responsible person. Location: Exit signs Comments: Provide documentation of testing all exit signs in building including repairs made to maintain working properly, documentation shall include signature and date of responsible person. GENERATED ON 1/22/26, 8:29 AM 2 OF 8 Fire Sprinkler System Status Code Fail 5.2.1.1.5 - Missing escutcheons Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. Description Location: Demo Room Comments: Sprinkler escutcheon shall be tight to ceiling. GENERATED ON 1/22/26, 8:29 AM 3 OF 8 Fire Service Features Status Code Fail Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Description Location: Tire center "Sprinkler Riser Room" Comments: Remove storage from riser room. No storage shall be kept in room. Location: Tire center Comments: Remove obstructions (carts) blocking access to Fire Hose Connection, maintain clear access at all times. GENERATED ON 1/22/26, 8:29 AM 4 OF 8 Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Additional Codes Status Code Fail Fail 603.1- General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. 913.5 - Testing and maintenance. Fire pumps shall be inspected, tested and maintained in accordance with the requirements of this section and NFPA 25. Records of inspection, testing and maintenance shall be maintained. Electrical Safety Status Code Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Receiving back hallway Comments: Remove obstructions (storage) blocking access to Fire Hose Connection, maintain clear access at all times. Description Location: HMS kitchen Comments: Remove rice cooker from power strip. Appliance shall plug directly to permanent wall receptacle. Location: Fire pump Comments: Provide corrections regarding report #8398157 on Compliance Engine. Report of corrections made shall be uploaded to Compliance Engine. s® Description Location: "Fresh Office" Comments: Replace missing outlet cover behind fridge. GENERATED ON 1/22/26, 8:29 AM 5 OF 8 Fire Resistant Construction Maintenance Status Code Fail Fail Fail 704.1- Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 705.2.6 - Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Description Location: Cash room door Comments: Carefully remove tape and/or paint covering fire rating tags without altering tag information. Location: IT Room Comments: Carefully remove tape and/or paint covering fire rating tags without altering tag information. Location: Tire center Comments: Provide documentation of annual inspection of fire door drop testing. GENERATED ON 1/22/26, 8:29 AM 6 OF 8 Portable Fire Extingusihers Status Code Fail 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Description Location: Tire center Comments: Annually serviced fire extinguisher shall be hung on wall bracket. Currently sitting in shopping cart. GENERATED ON 1/22/26, 8:29 AM 7 OF 8 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $600.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 1R2R6, 8:29 AM 8 OF 8