HomeMy WebLinkAbout1425 E SAN MARNAN AVEINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
01/27/2026
03/03/2026
2026-00000304
$200.00
Customer #: 14982
LONGHORN STEAKHOUSE #5374
1425 E SAN MARNAN AV
WATERLOO, IA 50702
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION - 1425 E SAN MARNAN DR -
01 /22/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION 3
$200.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
14982
01/27/2026
03/03/2026
2026-00000304
$200.00
Less Prepayment
Total Due -->
City of Waterloo
$0.00
$200.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Longhorn Steakhouse -1425 E San Marnan DR, BLDG 1425 E San Marnan Dr,
Waterloo IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type
01/22/2026 Annual Inspection (1Yr) LREINSPECTION,
Lead Inspector
BRAD BALDWIN
Other Inspectors
N/A
425 E. 3rd Street
Inspection Number
14817-R7
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
G 0 () 2
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 12/29/2025 @ 14:16
$100 re -inspection fee, failure to complete corrections as of 8129/25.
BRAD BALDWIN - 12/29/2025 @ 14:16
Corrected on site (8/29/25): Caroline cleaned dust of kitchen sprinkler heads.
BRAD BALDWIN - 12/29/2025 @ 14:16
$80 annual inspection fee
BRAD BALDWIN - 12/29/2025 @ 14:16
Fire extinguishers due serviced October 2025.
BRAD BALDWIN - 12/29/2025 @ 14:16
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 12/29/2025 @ 14:16
Reinspection Date
02112/2026
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 12/29/2025 @ 14:16
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 12/29/2025 @ 14:16
Withholding re -inspection today 9/0/25, waiting on Compliance Engine reports
BRAD BALDWIN - 12/29/2025 @ 14:16
$150 re -inspection fee, failure to correct deficiencies. Met with Caroline today to discuss open deficiencies. Complete corrections to avoid denial of liquor
license renewal application.
GENERATED ON 1/22/26, 12:45 PM 1 OF 3
BRAD BALDWIN -12129/2025 @ 14:16
Withholding re -inspection fee today due to new deficiency, all prior deficiencies have been corrected.
BRAD BALDWIN -12/29/2025 @ 14:16
$200 re -inspection fee, failure to complete correction as of 12/29125.
BRAD BALDWIN - 01/22/2026 @ 12:43
$200 re -inspection fee, failure to correct deficiencies as of 1/22126.
SIGNATURES
Contact signature
Caroline (2025) Mgr
CHECKLISTS
Additional Codes
Status
Fail
0
Reinspection
Status
Fail
No signature
Report completed post inspection
Code
Inspector signature
Date: BRAD BALDWIN
901.4 - Installation.Fire protection and life safety systems.
Fire protection systems shall be maintained in accordance
with the original installation standards for that system.
Required systems shall be extended, altered or augmented as
necessary to maintain and continue protection where the
building is altered, remodeled or added to. Alterations to fire
protection systems shall be done in accordance with
applicable standards. Fire protection and life safety systems
shall be installed, repaired, operated and maintained in
accordance with this code and the International Building
Code.
Code
Chapter 14 - Inspection, testing, and maintenance
Fire alarm system tested at least annually by licensed
contractor
Description
Location: Sprinkler system
01/22/2026
Comments: 5 year sprinkler system inspection due as of 1121/26.
Provide inspection report including any deficiencies corrected to
Compliance Engine.
Description
Location: Fire Alarm
Comments: Deficiency noted in Compliance Engine per report
#8307187 (Johnson Controls). Provide report of correction of
deficiency uploaded to Compliance Engine.
Additional comments: Deficiency still remains on Compliance Engine
on 1/22126
GENERATED ON 1/22/26. 12:45 PM 2 OF 3