HomeMy WebLinkAbout707 W 7TH STINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
02/03/2026
03/09/2026
2026-00000061
$100.00
Customer #: 24033
IA INVESTMENT PROPERTY
5195 HAMPSTEAD VILLAGE CTR WAY
NEW ALBANY, OH 43054
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL FIRE INSPECTION - 707 W 7TH ST - 02/03/2026
OWNERS NO SHOWED
FOR BILLING INQUIRY: (319)291-4323
Description
NO SHOW INSPECTION FEE
Total Price
$100.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24033
02/03/2026
03/09/2026
2026-00000061
$100.00
Less Prepayment
Total Due —
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
A1,00 2.mos3
Waterloo Fire Rescue
Inspection Report
707 W. 7TH ST - 701-709 W 7TH ST, BLDG 701-709 W 7TH ST, WATERLOO IA 50702
INSPECTION DETAILS
Inspection Date
02/03/2026
Lead Inspector
MIKE HEERKES
Inspection Type
Rental Inspection ( REINSPECTION
Other Inspectors
NATE BEUSELING
Shift
NIA
425 E. 3rd Street
Inspection Number
16745-R1
Station Unit
NIA NIA
SUMMARY OF INSPECTION
0 o
Passed codes
NEXT STEPS
0 15
Failed codes
Please direct questions about your Inspection to:
MIKE HEERKES
mike.heerkes@waterloo-ia.org, 3192914319
GENERAL NOTES
NATE BEUSELING - 02/03/2026 @ 09:28
Reinspection requested by owners for 2-3-2026, Owners no showed 100.00 fee implemented
SIGNATURES
Contact signature Inspector signature
Alain Ndoutoume
CHECKLISTS
No signature
Report completed post inspection
Reinspection Date
03105/2026
Date: MIKE HEERKES 02/03/2026
GENERATED ON 2/3/26, 9:32 AM 1 OF 5
Reinspection
Status Cods
Fail 603.2 - Abatement of unsafe conditions and electrical
Fail
Fail
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Fail 603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Description
Location: Bedroom
Comments: Ceiling light fixture missing appropriate globe/cover.
Location: Hallway
Comments: Ceiling light fixture missing appropriate globe/cover.
Location: Kitchen
Comments: Ceiling light fixture missing appropriate globeicover.
Location: Common entryway to both rental units.
Comments: Ceiling light fixture missing appropriate globe/cover.
GENERATED ON 2/3/26, 9:32 AM 2 OF 5
Fail
704.1- Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Fail 907.2.11.2 - Groups R-2, R-3, R-4 and I-1.
Single- or multiple -station smoke alarms shall be installed
and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1.On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2.In each room used for
sleeping purposes. 3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level.
Fail
Fail
Fail
Fail
O
915.2.1 - Dwelling units.
Carbon monoxide detection shall be installed in dwelling
units outside of each separate sleeping area in the immediate
vicinity of the bedrooms. Where a fuel -burning appliance is
located within a bedroom or its attached bathroom, carbon
monoxide detection shall be installed within the bedroom.
R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
Location: Hallway
Comments: Large hole in ceiling will need to be repaired with permits
and inspections to maintain code compliance with required fire
separation between rental units.
Comments: Smoke detectors are required in all sleeping units,
outside of sleeping units as well as on all levels of unit including
basement.
Location: Common entryway to both rental units
Comments: Replace entrance door with proper permits and
inspections
Location: Common entryway for both units
Comments: Condition of walls require cleaning and paint. (IPMC
305.3) Interior surfaces. Interior surfaces, including windows and
doors, shall be maintained in good, clean and sanitary condition.
Peeling, chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and other
defective surface conditions shall be corrected.
Location: Front entrance to rental unit
Comments: Replace entrance door with proper permits and
inspections
GENERATED ON 2/3/26, 9:32 AM 3 OF 5
Fail
Fail
Fail
Fail
Fail
R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
R6.C. - Mechanical Eqiupment
Are mechanical appliances properly installed and maintained
in good working condition? (IPMC 603.1)
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Location: Living room
Comments: Carpet tiles loose causing trip hazard.
Location: Living room - kitchen - bedroom - hallway - bathroom
Comments: Walls and ceilings need to be cleaned and/or painted.
(IPMC 305.3) - Interior surfaces. Interior surfaces, including windows
and doors, shall be maintained in good, clean and sanitary condition.
Peeling, chipping, flaking or abraded paint shall be repaired, removed
or covered. Cracked or loose plaster, decayed wood and other
defective surface conditions shall be corrected.
Comments: Evidence of pest infestation. promptly exterminated by
approved processes that will not be injurious to human health. After
pest elimination, proper precautions shall be taken to prevent
reinfestation.
Location: Kitchen
Comments: Stove is missing 2 burners.
Location: Bathroom
Comments: Sink faucet leaking.