COMMERCIAL FIRE INSPECTION - 210 DIVISION ST - 02/03/2026
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
20808
02/04/2026
03/11/2026
2026-00000326
$80.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Additional Codes
Status Cede
Fail
Fail
102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
603.1- General.
Electrical equipment, wiring and systems required by this
code or the International Building Code shall be installed,
used and maintained in accordance with NFPA 70 and
Sections 603.2 through 603.10.
Descrip i
Location: Water Heater
Comments: Contractor (Low Dollar Plumbing) shall obtain inspection
of water heater installed 6/16/25.
Location: Clothes dryer
Comments: Relocate clothes dryer to plug directly to permanent
outlet or licensed electrical contractor shall add new outlet by
obtaining proper permit and inspection. Removing dryer from
building would also suffice this inspection.
GENERATED ON 2/4/26, 8:33 AM
3 OF 6
Fail 610.1.1 - Installation.
Clothes dryer exhaust duct systems shall be installed in
accordance with the International Mechanical Code or the
International Fuel Gas Code , and the manufacturer's
installation instructions.
Fail 610.1.1 - Installation.
Clothes dryer exhaust duct systems shall be installed in
accordance with the International Mechanical Code or the
International Fuel Gas Code , and the manufacturer's
installation instructions.
Location: Clothes dryer
Comments: Licensed mechanical contractor shall install dryer vent to
comply with Mechanical Code, or remove dryer from use. Obtain
receipt of work completed by contractor to show inspector.
Location: Fridge at west end of bar
Comments: Remove fridge plugged to power strip, appliance shall
plug directly to permanent outlet.
GENERATED ON 2/4/26, 8:33 AM
4 OF 6
Waterloo Fire Rescue
Inspection Report
Babes - 210 Division ST, BLDG 210 Division St, Waterloo IA 50703
INSPECTION DETAILS
Inspection Date
02/03/2026
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
N/A
in rrt.
totbb
425 E. 3rd Street
Inspection Number
16113
Shift Station
Unit
N/A N/A N/A
SUMMARY OF INSPECTION
047 07 ®27
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 02/03/2026 @ 14:50
• $80 annual inspection fee
BRAD BALDWIN - 02/03/2026 @ 14:58
Christmas lighting approved for temporary usage (90 days).
BRAD BALDWIN - 02/03/2026 @ 15:04
Fire extinguishers due annually serviced January 2027
BRAD BALDWIN - 02/04/2026 @ 08:30
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
02/25/2026
BRAD BALDWIN - 02/04/2026 @ 08:30
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 02/04/2026 @ 08:30
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Ricky Julson
Date: BRAD BALDWIN 02/04/2026
GENERATED ON 2/4/26, 8:33 AM
1 OF 6
CHECKLISTS
2 OF 6
GENERATED ON 2/426, 8:33 AM
Electrical Safety
Status Code
Fail
Fail
Fail
603.5.2 - Application and usePower supply.
Relocatable power taps and current taps shall be directly
connected to a permanently installed receptacle. Exceptions:
1. Where approved for use in a Group A occupancy or in a
meeting room in a Group B occupancy, not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment. 2. Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
603.5.2 - Application and usePower supply.
Relocatable power taps and current taps shall be directly
connected to a permanently installed receptacle. Exceptions:
1. Where approved for use in a Group A occupancy or in a
meeting room in a Group B occupancy, not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment. 2. Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
603.5.2 - Application and usePower supply.
Relocatable power taps and current taps shall be directly
connected to a permanently installed receptacle. Exceptions:
1. Where approved for use in a Group A occupancy or in a
meeting room in a Group B occupancy, not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment. 2. Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
Description
Location: Walk-in fridge
Comments: Remove power strips daisy chained and remove
dehumidifier from power strip. Each individual power strip shall plug
directly to a permanent outlet used for light duty electric only.
Location: Office
Comments: Multiple power strips daisy chained above desk noted
today. Each individual power strip shall plug directly to a permanent
outlet used for light duty electric only.
Location: End of bar above chest freezer
Comments: Remove power strip daisy chained. Each individual
power strip shall plug directly to a permanent outlet used for light
duty electric only.
GENERATED ON 2/4/26, 8:33 AM