Loading...
HomeMy WebLinkAbout1738 FLOWER ST UNIT 2INVOICE DATE DUE DATE INVOICE # TOTAL DUE . 07/19/2023 07/25/2023 2024-00000031 $250.00 Customer #: 10811 DOMINIC TANGEN 2501 SCENIC DR CEDAR FALLS, IA 50613 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1738 FLOWER ST #2 - 7-13-23 FOR BILLING INQUIRY: (319)291-4323 Description Tota Price REINSPECTION FEE 3RD $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 10811 07/19/2023 07/25/2023 2024-00000031 Less Prepayment Total Due -* City of Waterloo $250.00 $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. INVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/24/2023 08/27/2023 2024-00000041 $250.00 Customer #: 10811 DOMINIC TANGEN 2501 SCENIC DR CEDAR FALLS, IA 50613 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1738 FLOWER ST #2 - 7-13-23 [ Description FOR BILLING INQUIRY: (319)291-4323 REINSPECTION FEE 3RD Total Price j $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 10811 07/24/2023 08/27/2023 2024-00000041 $250.00 Less Prepayment Total Due —* City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT DOMINIC TANGEN RENTAL 8-PLEX, 1738 FLOWER S DETAILS WATERLOO IA S0701 Inspection Date: 07/13/2023 I Inspection Type: Rental Inspection Inspection Number: 10475 1 Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: BARRY STRATTON Other Inspectors: N/A I Fee: $250.00 is STATUS CODE DESERI; 1013.3 - Illumination Exit signs shall be internally or externally illuminated. Exception: Tactile signs required by Section 1013.4 need not be provided with illumination. Inspector: BARRY STRATTON - Comments: Egress/exit lights Location: Interior of building FAIL 1025.5 - Illumination Where photoluminescent exit path markings are installed, they shall be provided with not less than 1 footcandle (11 lux) of illumination for not less than 60 minutes prior to periods when the building is occupied and continuously during the building occupancy. Inspector: BARRY STRATTON - Comments: None Location: Not Provided FAIL 1031.2 - Reliability Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. FAIL 605.1 - Abatement of electrical hazards Inspector: BARRY STRATTON - Comments: Outlets missing and wire being scrapped from building Location: All apartments. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Several electrical hazards exist throughout building. Location: Not Provided Printed on 07/13/2023 ;8 0726 Page 1 of 5 STATUS CODE' ' FAIL 703J 0peningproteoives 901/6 Inspection, testing and maintenance Opening protectives shall be maintained in an operative condition in accordance with NFPA 80. Where allowed by the fire code official, the application of field -applied labels associated with the maintenance ofopening proteoivesshall follow the requirements of the approved third -party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BARRYSTRATTON Comments: Alarm testing and maintenance has still not been done. Location: Not Provided Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times, and shall bereplaced orrepaired where defective. Nonrequiredfire protection systems and equipment shall be inspected, tested and maintained or removed. Inspector: BARRY STRATT N-0mmemsAlarm Location: Not Provided FAIL 901.61 Standards Fire protection systems shall be inspected, tested and maintained in accordance with the referenced standards listed in Table . Inspector: BARRYSTRATT0N Comments: None Location: Not Provided FAIL 9061 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A,B'�F,H'|.Kd'R'1'R,2,R4and Soccupancies. Exception: \n Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having aminimum rating of1`A:10'B:LJ.Within 30feet (9144mm) of commercial cooking equipment. 3.|nareas where flammable orcomhustib|e liquids are stored, used ordispensed. 4.0neach floor ofstructures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required bythe sections indicated \nTable 9O0.1.6. Speda|'haza,dareas' including but not limited to laboratories, computer rooms and generator rooms, where required bythe fire code official. Inspector: BARRY5TRATT0N'Comments: None Location: Not Provided Printed onmn~2023m07:26 Page uma Sn4TUS CODE DESCRIPTION . | 9072.11 Single- and multiple -station smoke alarms Listed single-andmultiple- station smoke alarms complying with UL217shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRYSTRATT0N Comments: Detectors missing throughout building and all apartments. Location: Interior ofBuilding FAIL RZ Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) Inspector: BARRYSTRATTOm Comments: All units are uninhabitable. Building does not rneet fire safety and rental requirements. Location: Not Provided FAIL R3 Unfit for Human Is the structure found mbe fit for human occupancy according to the code? (IPIVIC Occupancy 10813) Inspector: BARRYSTRAlTON Comments: Apartments 1'8 Location: Not Provided FAIL R4 Exterior Property Areas |sthe exterior property area maintained inaclean, safe, and sanitary condition? This includes grading anddminage'sidewuUmanddriveways,wpeds.andpesz infestations. (|PK4[3O2) Location: Not Provided FAIL R5 Exterior Structure |sthe exterior cfthe structure maintained ingood repair, structurally sound and sanitary state? (|Pk4{304 Inspector: BARRYSTRATT0N'Comments: Windows, doors, electrical Location: Not Provided FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and inasanitary condition? (IPK4C]O5) Inspector: B4RRYSTRATT0N Comments: All units 1'8unfit nnoccupy Location: Not Provided P,mted on 07113i2023 ��'m-26 Page unr5 STAFUS CODE FAIL R6.A. - Interior Structure - Unsafe Conditions Were any unsafe conditions noted during the interior inspecdon?(|PNK3O5J1) Inspector: BARRYSTRATT0N Comments: None Location: Not Provided FAIL R6.B. Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom temperature of68R(|PMC602.2) Location: Not Provided FAIL ROl. MechuniuolEqiupmenc Are mechanical appliances properly installed and maintained in good working condition? (lPK4[8O31) Inspector: 8ARRYSTRATTON Comments: None Location: Not Provided GENERAL NOTES BARRYSTRA7TOM'07Y13/2OZ3@O7:Z5 9�-49�-5:2O23Rental Registration i»needed. Still not registered aEImSPccnmmo4TE 08/17/2023 CONTACT SIGNATURE Dominic Tangen INSPECTOR SIGNATURE BARRYSTKAlT0N 3� Printed onomsm23 L& 07:26 Page 4ma QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319) 231-9147 Printed on 07/13/2023 0726 Page 5 of 5