Loading...
HomeMy WebLinkAbout200 INDEPENDENCE AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/24/2023 08/27/2023 2024-00000038 $250.00 Customer #: 24033 IA INVESTMENT PROPERTY 5001 1ST AVE SE SUITE 105,221 CEDAR RAPIDS, IA 52402 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 200 INDEPENDENCE AVE - 7-17-23 FOR BILLING INQUIRY: (319)291-4323 [ Description REINSPECTION FEE 3RD Total Price $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24033 07/24/2023 08/27/2023 2024-00000038 $250.00 Less Prepayment Total Due — City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. INVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/19/2023 07/25/2023 2024-00000028 $250.00 Customer #: 23001 QUALITY CONCRETE CONTRUCTION (RENTAL) 1930 HAWTHORNE AVE #1 WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 200 INDEPENDENCE AVE 7-17-23 FOR BILLING INQUIRY: (319)291-4323 Description', Total Price J REINSPECTION FEE 3RD $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23001 07/19/2023 07/25/2023 2024-00000028 $250.00 Less Prepayment Total Due -* City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. r WATERLOO FIRE RESCUE INSPECTION RE •N`-,T �` QUALITY CONCRET N, ULTU UNIT COMPLEX, 200 INDEPENDENCE AVE, WATERL00 IA SO 03 3 yo3 DETAILS Inueatimtvykk Inspection Date: 07/17/2023 Inspection Type: Rental Inspection Inspection Number: 10480 Shift: N/A Station: N!A Unit: N/A Lead Inspector: BARRY STRATTON Other Inspectors: N/A i Fee: $250.00 '°1-4 Af-//-ette(5)(f) Lgor' STATUS CODE DES RI TION � FAIL 1010.1.9 - Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: None Location: Not Provided FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. FAIL 605.1 - Abatement of electrical hazards Inspector: BARRY STRATTON - Comments: None Location: Not Provided Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: None ation: Not Provided P_ •=-ted a : 07/17/2023 t 09:56 Page 1 of 3 . STATUS CODE Ofscn/pnow 9001 Where required Portable fire extinguishers shall beinstalled inall cfthe following locations: 1.mnew and existing Group A,E, E, F,H'|'w.R,1'R2,R4and Soccupancies. Exception: |n Group R-2 Occupancies, portable fire extinguishers shall be required only in locations specified in Iterns 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having aminimumrating of1`A: 18'B:[.2.Within JOfeet (9144mm) ofcommercial cooking equipment. 3.|nareas where flammable orcombustible liquids are stored, used ordispensed. 4.0neach floor ofstructures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required bythe sections indicated inTable 980.1.0.Special-hazard areas, including but not limited tnlaboratories, computer rooms and generator rooms, where required bythe fire code official. Inspector: BARRYSTR/TT8N Comments: Need Fire extinguisher Location: Not Provided FAIL RO'Interior Structure Has the interior cf the structure and equipment inside been maintained ingood repair, structurally sound, and in a sanitary condition? (IPMC 305) |n»pecVoc0ARRYSTRATT0N Comments: Peeling and abraded paint throughout. Kitchen sink will not drain and is still leaking. Ceiling in bedroom falling and peeling paint. Bathroom tub and shower valve needs replaced. Tub has peeling paint used in tub. Peeling paint in bathroom, bedrooms, doors, handrail busted to upstairs broken windows. Location: Not Provided FAIL RO�. Interior Structure- Were any unsafe conditions noted during the interior Pw[3051.1) Unsafe Conditions Inspector: BARRYSTRATT0N Comments: Peeling and abraded paimdxouXhoot Kitchen sink will not drain and is still leaking. Ceiling in bedroom falling and peeling paint. Bathroorn tub and shower valve needs replaced. Tub has peeling paint used in tub. Peeling paint in bathroom, bedrooms, doors, handrail busted to upstairs broken windows. Location: Not Provided FAIL K6.8. Residential Heating Are dwellings provided with heating facilities capable nfmaintaining aroom temperature of68F?(|PM{60Iq Inspector: BARRYSTRATT0N Comments: Register covers Location: Not Provided FAIL RhI. Mechanka|Eqiupmern Are mechanical appliances properly installed and maintained ingood working P,;nzeo on 07117/2023&� 093f, Page uoxo STATUS GENERAL NOTES BARRYSTRATTON 07Y17/2023@ 09:56 DE$CIUwKDON inspector: 8ARRYSTRATT0N Comments: Water heater installed without permits and inspections and still missing discharge tube. Location: Not Provided 111.0Transfer ofowner hip.|tshaUheun|amfu|kxchenwoerofonydweUingunito/ structure who has received a compliance order or upon whom a notice of violation has been served to sell, transfer, mortgage, lease or otherwise dispose of such dwelling unit or structure to another until the provisions of the compliance order or notice of violation have been complied with, or until such owner or the owners authorized agent shall first furnish the grantee, transferee, mortgagee or lessee a true copy of any compliance order or notice of violation issued by the code official and shall furnish to the code official a signed and notarized statement from the grantee, transferee, mortgagee or lessee, acknowledging the receipt of such compliance order of notice of violation and fully accepting the responsibility without condition for making the corrections or repairs required by such compliance order or notice of violation. BARRY5TRATT0N 0Y17/2023@ 09:50 9-7-7:INSPECTIONS REQUIRED nmmSpEcnumo4rE 08/21/2023 CONTACT SIGNATURE Joyce Wood INSPECTOR SIGNATURE BARRYSTR/UTON QUESTIONS ABOUT YOUR INSPECTION? BARRYSTRATTON Ua/ry.strauon@wanedoo'ia.nrg (319) 231-9147 Printed onm=nQQ 13m09 56 Page am3