Loading...
HomeMy WebLinkAbout3225 AIRPORT BLVDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 05/21/2024 06/25/2024 2024-00000382 $100.00 Customer #: 24359 CAMP RUN A MUTT 3225 AIRPORT BLVD. WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3225 AIRPORT BLVD - 4-18-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24359 05/21/2024 06/25/2024 2024-00000382 $100.00 Less Prepayment Total Due —� City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT CAMP RUN A MUTT, 3225 AIRPORT BLVD AIRPORT BLVD, BLDG 3225 AIRPORT BLVD, WATERLOO /A 50703 DETAILS Inspection Date: 04/18/2024 I Inspection Type: Annual Inspection (1Yr) ! Inspection Number: 12926 ' Shift: N/A j Station: N/A Unit: N/A Lead Inspector: JEREMIAH VANDYKE Other Inspectors: N/A Fee: $100.00 VIOLATIONS AND COM►LIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 46 I Violations: 6 I N/A Codes: 23 STATUS CODE DESCRIPTION FAIL 509.1 - Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves, or other fire detection, suppression or control elements fire protection systems shall be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Location: Room containing Main electrical, Sprinkler riser, and Fire alarm control panel (FACP). FAIL 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Location: Room containing Main electrical, Sprinkler riser, and Fire alarm control panel (FACP). Original Comment: Storage in front of electrical panel, sprinkler riser, and fire alarm needs 36 inch clearance. Printed on 04/18/2024 @ 15:21 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 603.4.1 - Labeling. Doors into electrical control pan& rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Location: Room containing Main electrical, Sprinkler riser, and Fire alarm control panel (FACP). Original Comment: Durable signage on door or next door stating, "Main Electrical, Sprinkler Riser, and FACP" FAIL 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. FAI L Location: Clothes dryer Original Comment: Clothes Dryer Exhaust Duct system must be cleaned from the dryer to the outside DOCUMENTED by who and when serviced. Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor testing, and maintenance Location: Fire alarm panel. Original Comment: Fire alarm needs to be inspected annually and report uploaded to our Compliance engine by fire alarm contractor after inspection. Printed on 04/18/2024 @ 15:21 Page 2 of 4 • STATUS CODE DESCRIPTION FAIL Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor testing, and maintenance Location: Jack and jilt bathroom in back. Original Comment: Missing smoke alarm needs to be replaced by Fire alarm contractor. GENERAL NOTES JEREMIAH VANDYKE - 04/18/2024 @ 15:03 Fire extinguishers serviced by Prosheild August 2023. JEREMIAH VANDYKE - 04/18/2024 @ 15:04 02/28/2024 S - (Annual) Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE - 04/18/2024 @ 15:04 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone # 319-291-2515. JEREMIAH VANDYKE - 04/18/2024 @ 15:04 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re - inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 04/18/2024 @ 15:04 Lt. Van Dyke-jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883- 1615 JEREMIAH VANDYKE - 04/18/2024 @ 15:05 Inspection Fee = $100.00 (To be mailed out by City via snail mail.) REINSPECTION DATE 05/18/2024 Printed on 04/18/2024 @ 15:21 Page 3 of 4 CONTACT SIGNATURE Stef Hartel Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 04/18/2024 @ 15:20 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 04/18/2024 @ 15:21 Page 4 of 4