Loading...
HomeMy WebLinkAbout3780 CROSSROADS BLVDCustomer #: 9993 APPLEBEE'S 2780 CROSSSROADS BLVD WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 05/21/2024 06/25/2024 2024-00000358 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT COMMERCIAL INSPECTION [ Description KEEP THIS PORTION FOR YOUR RECORDS - 2780 CROSSROADS BLVD - 5-14-24 FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 9993 BILLING DATE 05/21/2024 DUE DATE 06/25/2024 INVOICE # 2024-00000358 CHARGES Less Prepayment Total Due —� City of Waterloo $80.00 $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT APPLEBEE"S, 2780 CROSSROADS BLVD, BLDG2780 CROSSROADS BLVD, WATERLOO IA S0702 DETAILS gqG3 Inspection Date: 05/14/2024 ; Inspection Type: Annual Inspection (1Yr) I Inspection Number: 11596 M Shift: N/A Station: N/A ; Unit: N/A Lead Inspector: JEFF SIEBEL ; Other Inspectors: N/A Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 ; Passed Codes: 43 ; Violations: 4 ; N/A Codes: 28 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: Not Provided Original Comment: Obtain plumbing permit and inspections for new water heater Printed on 05/15/2024 @ 15:16 Page 1 of 4. STATUS CODE DESCRIPTION FAIL 305.1 - Clearance from Clearance between ignition sources, such as luminaires, heaters, flame - ignition sources. producing devices and combustible materials, shall be maintained in an approved manner. FAIL 509.2 - Equipment access. Location: next to grill Original Comment: remove waste can from cookline. maintain proper clearances from cooking equipment to combustibles Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Location: front entry Original Comment: Fire annunciator panel is blocked by display. Remove display and maintain a minimum of 36" clearance at all times to fire annunciator. Printed on 05/15/2024 @ 15:16 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 606.2 - Where required. A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m3 or Tess of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 710B. Location: burner range Original Comment: relocate range so cooking surface is a minimum of 6 " under exhaust hood. GENERAL NOTES JEFF SIEBEL - 05/15/2024 @ 15:15 annual inspection $80 REINSPECTION DATE 06/04/2024 CONTACT SIGNATURE Lenny Gielau Signed on: 05/15/2024 @ 15:15 Printed on 05/15/2024 @ 15:16 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 05/15/2024 @ 15:15 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/15/2024 @ 15:16 Page 4 of 4