Loading...
HomeMy WebLinkAbout106 BROOKERIDGE DRCustomer #: 4469 GOLDEN CHINA 106 BROOKERIDGE DR WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/06/2024 07/10/2024 2024-00000398 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN:: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 106 BROOKERIDGE DR - 3-21-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price ] $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 4469 06/06/2024 07/10/2024 2024-00000398 $80.00 Less Prepayment Total Due —÷ City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE r �,�0c\ INSPECTION REPORT 1 GOLDEN CHINA, 106 BROOKERIDGE DR, BLDG 106 BROOKERIDGE DR, WATERLOO LA 50702 DETAILS Inspection Date: 03/21/2024 Inspection Type: Annual Inspection (1Yr) I Inspection Number: 9848 I Shift: N/A I Station: N/A Unit: N/A Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 28 I Violations: 6 I N/A Codes: 40 STATUS CODE DESCRIPTION FAIL 305.1 - Clearance from Clearance between ignition sources, such as luminaires, heaters, flame - ignition sources. producing devices and combustible materials, shall be maintained in an approved manner. Location: kitchen grill area Original Comment: remove all grease container storage and cardboard from under cooking appliances and keep 36" clearance. FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Back room Original Comment: remove obstructions to electric panel. Maintain a minimum of 36" clearance at all times. Printed on 03/22/2024 @ 11:58 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days. Temporary wiring methods shall meet the applicable provisions of NFPA 70. Exception: Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. Location: front lobby Original Comment: Decorative light strings meant for temporary use only. May be up for 90 days at a time. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: kitchen hood cleaning Original Comment: provide current semi-annual kitchen hood exhaust cleaning inspection report with all discrepancies corrected. Currently past due. Contractor must upload online to the compliance engine. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: kitchen hood fire suppression Original Comment: provide current semi-annual kitchen hood fire suppression inspection report with all discrepancies corrected. Currently past due. Contractor must upload online to the compliance engine. Printed on 03/22/2024 @ 11:58 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Not Provided Original Comment: provide annual service for fire extinguishers GENERAL NOTES JEFF SIEBEL - 03/22/2024 @ 11:56 annual inspection $80 REINSPECTION DATE 04/11/2024 CONTACT SIGNATURE Yeli Chiu Signed on: 03/22/2024 @ 11:56 Printed on 03/22/2024 @ 11:58 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 03/22/2024 @ 11:56 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 03/22/2024 @ 11:58 Page 4of4