Loading...
HomeMy WebLinkAbout2424 RANCHERO RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 06/06/2024 07/10/2024 2024-00000412 $80.00 Customer #: 15371 CASEY'S GENERAL STORE #2867 1 SE CONVENIENCE BLVD ANKENY, IA 50021 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2424 RANCHERO RD - 5-21-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price J $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 15371 06/06/2024 07/10/2024 2024-00000412 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE &D'1) INSPECTION REPORT CASEY'S GENERAL STORE #2867, 2424 RANCHERO RD, BLDG 2867 RANCHERO RD, WATERLOO IA S0701 DETAILS Inspection Date: 05/21/2024 I Inspection Type: Annual Inspection (1Yr) I Inspection Number: 10489-R1 i Shift: N/A ; Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 1 I Passed Codes: 0 I Violations: 3 I N/A Codes: 1 STATUS CODE DESCRIPTION FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: storage room by office Original Comment: Remove storage in front of electrical panel. maintain a minimum of 36" clearance at al times. Additional Comment: Remove gasoline from building Printed on 05/22/2024 @ 08:04 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). FAI L GENERAL NOTES 904.13.5.2 - Extinguishing system service. Location: electrical room by kitchen. Original Comment: remove storage from within 36" of electrical panel. Install permanent signage on electrical panels stating " NO STORAGE MAINTAIN 36" CLEARANCE" .REPEAT VIOLATION. re -inspection fees will apply if not corrected. Additional Comment: Repeat violation Automatic fire -extinguishing systems shall be serviced not less frequently than every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. Location: Not Provided Original Comment: Provide current semi-annual kitchen hood fire suppression inspection report with all discrepancies corrected. Currently 20 days past due. Contractor must upload online to the compliance engine. JEFF SIEBEL - 05/01/2024 @ 09:17 annual inspection fee $80 Printed on 05/22/2024 @ 08:04 Page 2 of 3 GENERAL NOTES JEFF SIEBEL - 05/22/2024 @ 08:00 re -inspection fee $100. repeat offenses. REINSPECTION DATE 06/11/2024 CONTACT SIGNATURE Christine Crane 2023 Signed on: 05/22/2024 @ 08:00 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 05/22/2024 @ 08:01 QUESTIONS AMOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/22/2024 @ 08:04 Page 3 of 3