COMMERCIAL INSPECTION - 2600 E SHAULIS RD - 4-23-24
FOR BILLING INQUIRY: (319)291-4323
[ Description
INSPECTION 100,000
OCCUPANCY FEE
Total Price ]
$600.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
10030
05/02/2024
06/10/2024
2024-00000349
$610.00
Less Prepayment
Total Due
City of Waterloo
$0.00
S610.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
G}
WATERLOO FIRE RESCUE mqi (1-6
INSPECTION REPORT
MAIN ADMINISTRATION OFFICE, 2600 E SHAIILIS RD, BLDG MAIN ADMINISTRATION OFFICE,
WATERLOO IA S0701
DETAILS
--rberiv2_ PaAk
Inspection Date: 04/23/2024 i Inspection Type: Annual Inspection (1Yr) I Inspection Number: 10691 i Shift: N/A Station: N/A I
Unit: N/A j Lead Inspector: JEFF SIEBEL € Other Inspectors: BROCK WELIVER, JEREMIAH VANDYKE I Fee: $600.00
`O
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 35 I Violations: 13 I N/A Codes: 34
STATUS CODE DESCRIPTION
FAI L
1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in
illumination. accordance with Sections 1008.3 and 1104.5.1.
FAIL - 1203.2.15 - Means of egress
FAI L
Location: Entire Administration Building
Original Comment: Provide documentation of testing and repair of all egress and
exit lights with signature and date including hall outside of restrooms and in NW
corner.
Emergency power shall be provided for means of egress illumination in
illumination. accordance with Sections 1008.3 and 1104.5.1.
Location: Yuta Falls
Original Comment: repair egress light
1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in
illumination. accordance with Sections 1008.3 and 1104.5.1.
Location: Midway games
Original Comment: repair egress lights
Printed on 04/30/2024 @ 11:26
Page 1 of 6
STATUS CODE DESCRIPTION
FAIL 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in
illumination. accordance with Sections 1008.3 and 1104.5.1.
FAIL
FAIL
Location: AWA women's restroom
Original Comment: repair egress lights
1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in
illumination. accordance with Sections 1008.3 and 1104.5.1.
Location: Wilbo grill
Original Comment: Test and repair all egress lights and document with signature
and date. Lights too high to test.
1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in
illumination. accordance with Sections 1008.3 and 1104.5.1.
Location: Purple roller coaster building
Original Comment: repair egress lights.
FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.
The system shall be capable of powering the required load for a duration of not
less than 90 minutes.
Location: Skyborne
Original Comment: repair all exit lights.
Printed on 04/30/2024 Ca 11:26
Page 2 of 6
STATUS CODE DESCRIPTION
FAIL 316.3 - Pitfalls. The intentional design or alteration of buildings to disable, injure, maim or kill
intruders is prohibited. A person shall not install and use firearms, sharp or
pointed objects, razor wire, explosives, flammable or combustible liquid
containers, or dispensers containing highly toxic, toxic, irritant or other
hazardous materials in a manner that could passively or actively disable, injure,
maim or kill a fire fighter who forcibly enters a building for the purpose of
controlling or extinguishing a fire, rescuing trapped occupants or rendering
other emergency assistance.
Location: Purple roller coaster maintenance building.
Original Comment: Properly cover pit or install guard rails or safety chains.
FAIL 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system
of a clothes dryer shall be maintained in accordance with the manufacturer's
operating instructions to prevent the accumulation of lint or debris that prevents
the exhaust of air and products of combustion.
Location: Admin blg
Original Comment: provide documentation of dryer vent cleaning to the outside
of the building with date and signature.
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Admin Building
Original Comment: replace missing ceiling tile East Entry
Printed on 04/30/2024 @ 11:26
Page 3 of 6
STATUS CODE DESCRIPTION
FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and
protection. systems used to protect joints and voids in the following locations shall be
maintained. The materials and systems shall be securely attached to or bonded
to the adjacent construction, without openings visible through the construction.
1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling
assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids
at the intersection of a horizontal floor assembly and an exterior curtain wall.
4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain
wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and
an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an
exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a
nonfire-resistance-rated roof assembly. Unprotected joints and voids do not
need to be protected where such joints and voids were not required to be
protected when the building was originally constructed. Where the system design
number is known, the system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Location: Admin Building
Original Comment: Fire Door to IT room is propped open. Door to remain closed
at all times unless operated by fire alarm system. (no alarm system in building).
FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
Location: Urban Delight
Original Comment: provide annual service for fire extinguisher
Printed on 04/30/2024 @ 11:26
Page 4 of 6
STATUS CODE DESCRIPTION
FAIL 906.2 - General requirements.
GENERAL NOTES
JEFF SIEBEL - 04/30/2024 @ 10:26
JEFF SIEBEL - 04/30/2024 @ 10:28
JEFF SIEBEL - 04/30/2024 @ 11:09
REINSPECTION DATE
05/22/2024
Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
Location: Ummi Ummi blg
Original Comment: provide annual fire extinguisher service and properly mount
4" to 5' above the floor in a readily accessible location.
All buildings inspected are on this report except Whale Bone, Maintenance shop,
volakana , thirsty voyaer and torora market which have individual reports due to the
fire safety systems installed in them.
Total of all buildings annual inspec
Private hydrants inspected by black hawk sprinkler 9/20/23
Printed on 04/30/2024 @ 11:26
Page 5of6
CONTACT SIGNATURE
Bill Brousseau
Signed on: 04/30/2024 @ 11:25
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 04/30/2024 @ 11:25