Loading...
HomeMy WebLinkAbout821 BROADWAY STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 05/02/2024 06/10/2024 2024-00000324 $80.00 Customer #: 13529 BROADWAY LIQUOR 821 BROADWAY ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 821 BROADWAY ST - 4-22-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price ] $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 13529 05/02/2024 06/10/2024 2024-00000324 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT BROADWAYLIQUOR, 821 BROADWAYST, BLDG 821 BROADWAYST, WATERLOO IA 50703 DETAILS Inspection Date: 04/22/2024 ( Inspection Type: Annual Inspection (1Yr� Inspection Number: 10512 Shift: N/A : Station: N/A Unit: N/A Lead Inspector: JEFF SIEBEL 1 Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 28 I Violations: 5 I N/A Codes: 41 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. FAI L 603.2.2 - Unapproved conditionsOpen electrical terminations. Location: Not Provided Original Comment: Obtain plumbing permit and inspections for water heater installed without. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: walk in cooler Original Comment: replace missing moisture proof light cover. Printed on 04/23/2024 @ 10:19 Page 1 of 3 STATUS CODE DESCRIPTION FAI L 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: front window of kitchen. Original Comment: remove multi -plug adapter. Power strip with reset may be utilized for lights and computers only. Must be plugged directly into wall outlet and properly mounted. FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: Kitchen hood fire suppression inspection Original Comment: Provide current semi-annual kitchen hood fire suppression system inspection with all discrepancies corrected. Currently 148 days past due. Contractor must upload report online to the compliance engine. FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Not Provided Original Comment: provide annual service for fire extinguisher. Printed on 04/23/2024 @ 10:19 Page 2 of 3 STATUS CODE DESCRIPTION GENERAL NOTES JEFF SIEBEL - 04/23/2024 @ 10:14 annual inspection $80 REINSPECTION DATE 05/20/2024 CONTACT SIGNATURE Muhammad Shahaz Signed on: 04/23/2024 @ 10:14 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 04/23/2024 @ 10:14 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/23/2024 @ 10:19 Page 3 of 3