COMMERCIAL INSPECTION - 1459 ANSBOROUGH AVE - 4-22-24
[ Description
FOR BILLING INQUIRY: (319)291-4323
INSPECTION 2,000
OCCUPANCY FEE
Total Price ]
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24128
05/02/2024
06/10/2024
2024-00000322
$80.00
Less Prepayment
Total Due -*
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
BEST DEALS, 1459ANSBOR000HAVE, BLDG 1459ANSBOR000HAVE, WATERLOO IA 50701
DETAILS
Inspection Date: 04/22/2024 ( Inspection Type: Annual Inspection (1 Yr)) nspectio) Number: 10810 j Shift: N/A Station: N/A
Unit: N/A ! Lead Inspector: JEFF SIEBEL j Other Inspectors: N/A ! F
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 23 I Violations: 6 I N/A Codes: 45
STATUS CODE DESCRIPTION
FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously
maintained free from obstructions or impediments to full instant use in the case
of fire or other emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be used for any purpose
that interferes with a means of egress.
FAI L
315.3.2 - Means of egress.
Location: Back hall to rear exit door
Original Comment: remove all cardboard and other storage from hall and
maintain clear path to rear exit or have area reviewed by an architect to remove
second exit if not needed.
Combustible materials shall not be stored in exits or enclosures for stairways
and ramps. Combustible materials in the means of egress during construction,
demolition, remodeling or alterations shall comply with Section 3312.3.
Location: rear exit hallway
Original Comment: remove all cardboard rubbish storage.
Printed on 04/23/2024 @ 09:46
Page 1 of 4
STATUS
FAIL
FAIL
CODE
603.4 - Working space and
clearancesclearance.
603.5 - Relocatable power
taps and current
taps.Multiplug adapters.
DESCRIPTION
A working space of not Working space around electrical equipment shall be
provided in accordance with Section 110.26 of NFPA 70 for electrical equipment
rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space shall be not less
than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches
(1981 mm) in height shall be providedin front of electrical service equipment.
Where the electrical service equipment is wider than 30 inches (762 mm), the
minimum working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2.
Access openings into attics or under -floor areas that provide a minimum clear
opening of 22 inches (559 mm) by 30 inches (762 mm).
Location: Behind front counter
Original Comment: Remove obstructions . Emergency fuel stop must be readily
accessible.
Multiplug adapters, such as cube adapters, unfused plug strips or any other
device not complying with NFPA 70 shall be prohibited. The construction and use
of current taps and relocatable taps shall be in accordance with NFPA 70 and this
code.
Location: front SW corner of store
Original Comment: properly mount power strip. Not allowed to hang by cords.
Printed on 04/23/2024 @ 09:46
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL
603.5 - Relocatable power
taps and current
taps.Multiplug adapters.
Multiplug adapters, such as cube adapters, unfused plug strips or any other
device not complying with NFPA 70 shall be prohibited. The construction and use
of current taps and relocatable taps shall be in accordance with NFPA 70 and this
code.
Location: Behind front counter
Original Comment: properly mount power strip. Power strip must not hang by
cord and properly mount.
FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring
and shall be listed and labeled in accordance with UL 817. Extension cords and
flexible cordsshall not be affixed to structures, extended through walls, ceilings
or floors, or under doors or floor coverings, nor shall such cords be subject to
environmental damage or physical impact. Extension cords shall be used only
with portable appliances. Extension cords marked for indoor use shall not be
used outdoors.
GENERAL NOTES
JEFF SIEBEL - 04/23/2024 @ 09:02
JEFF SIEBEL - 04/23/2024 @ 09:38
REINSPECT/ON DATE
05/21/2024
Location: Monster cooler by pipe counter
Original Comment: remove extension cord. Cooler must plug directly into
permanent power outlet.
annual inspection $80
Unable to access back door, restroom or liquor room. Provide access for inspections.