COMMERCIAL INSPECTION - 1022 ALABAR AVE - 4-3-24
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
4134
05/02/2024
06/10/2024
2024-00000321
$80.00
Less Prepayment
Total Due -*
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
CALICO HEN HOUSE, 1022 ALABAR AVE, BLDG 1022 ALABAR AVE, WATERLOO /A 50701
DETAILS
Inspection Date: 04/03/2024 j Inspection Type: Annual Inspection (1
Unit: N/A ' Lead Inspector: JEFF SIEBEL Other Inspectors: N/A
VIOLATIONS AND COMPLIANCES
•
Number: 1142 Shift: N/A j Station: N/A
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 16 I Violations: 10 1 N/A Codes: 49
STATUS CODE DESCRIPTION
FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.
The system shall be capable of powering the required load for a duration of not
less than 90 minutes.
Location: 1014 front exit
Original Comment: repair exit/egress light
FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.
The system shall be capable of powering the required load for a duration of not
less than 90 minutes.
Location: rear exit 1014
Original Comment: repair exit/egress light
FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.
The system shall be capable of powering the required load for a duration of not
less than 90 minutes.
Location: basement second exit
Original Comment: repair exit/egress light
Printed on 04/08/2024 @ 11:19
Page 1 of 7
STATUS CODE DESCRIPTION
FAIL 315.3.2 - Means of egress. Combustible materials shall not be stored in exits or enclosures for stairways
and ramps. Combustible materials in the means of egress during construction,
demolition, remodeling or alterations shall comply with Section 3312.3.
FAI L
315.3.3 - Equipment rooms.
Location: main store and 1014
Original Comment: remove obstructions in exit path to back doors. Maintain a
minimum of 36" clearance at all times and any storage must be stable and
secure.
Combustible material shall not be stored in boiler rooms, mechanical rooms,
electrical equipment rooms or in fire command centers as specified in Section
508.1.5.
Location: furnace rooms
Original Comment: remove all combustible storage from equipment rooms other
than maintenance items for equipment in the rooms.
Printed on 04/08/2024 @ 11:19
Page 2 of 7
STATUS CODE DESCRIPTION
FAIL
FAIL
603.2.2 - Unapproved
conditionsOpen electrical
terminations.
603.4 - Working space and
clearancesclearance.
Open junction boxes and open -wiring splices shall be prohibited. Approved
covers shall be provided for all switch and electrical outlet boxes.
Location: NE corner of 1014
Original Comment: install outlet cover.
A working space of not Working space around electrical equipment shall be
provided in accordance with Section 110.26 of NFPA 70 for electrical equipment
rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space shall be not less
than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches
(1981 mm) in height shall be providedin front of electrical service equipment.
Where the electrical service equipment is wider than 30 inches (762 mm), the
minimum working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2.
Access openings into attics or under -floor areas that provide a minimum clear
opening of 22 inches (559 mm) by 30 inches (762 mm).
Location: electrical panels and furnaces
Original Comment: remove obstructions . no storage in furnace rooms.
Printed on 04/08/2024 @ 11:19
Page 3of7
STATUS CODE DESCRIPTION
FAIL 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting
installations shall not exceed is allowed for a period not to exceed of 90 days.
Temporary wiring methods shall meet the applicable provisions of NFPA 70.
Exception: Temporary wiring for electrical power and lighting installations is
allowed complying with the applicable provisions of NFPA 70 is permitted during
periods of construction, remodeling, repair or demolition of buildings,
structures, equipment or similar activities.
Location: entire building
Original Comment: Temporary lighting only allowed to be used for 90 days and
may not be installed permanently installed. Only exceptions that string lights may
be permanently installed if they meet the following criteria: A. Manufacturer
specifications allow permanent installations. B. Lights are listed for use indoors.
C. Light are installed per listing and manufactureres recommendations. Lights
not allowed to be hung by or put strain on wiring. Lights were found to be
incorrectly installed with hooks and bent over nails.
Printed on 04/08/2024 @ 11:19
Page 4 of 7
STATUS CODE DESCRIPTION
FAIL 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In
new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies.
Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be
required only in locations specified in Items 2 through 6 where each dwelling unit
is provided with a portable fire extinguisher having a minimum rating of 1-A:10-
B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only
in locations specified in Items 2 through 6 where each classroom is provided with
a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage
areas of Group S occupancies where forklift, powered industrial truck or powered
cart operators are the primary occupants, fixed extinguishers, as specified in
NFPA 10, shall not be required where in accordance with all of the following: 3.1.
Use of vehicle -mounted extinguishers shall be approved by the fire code official.
3.2. Each vehicle shall be equipped with a 10-pound, 40A:80B:C extinguisher
affixed to the vehicle using a mounting bracket approved by the extinguisher
manufacturer or the fire code official for vehicular use. 3.3. Not less than two
spare extinguishers of equal or greater rating shall be available on -site to replace
a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper
operation, use and inspection of extinguishers. 3.5. Inspections of vehicle -
mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm)
distance of travel from commercial cooking equipment and from domestic
cooking equipment in Group 1-1; 1-2, Condition 1; and R-2 college dormitory
occupancies. 3.In areas where flammable or combustible liquids are stored, used
or dispensed. 4.On each floor of structures under construction, except Group R-3
occupancies, in accordance with Section 3316.1. 5.Where required by the sections
indicated in Table 906.1. 6.Special-hazard areas, including but not limited to
laboratories, computer rooms and generator rooms, where required by the fire
code official. Exception: Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where a portable fire
extinguisher suitable to the hazard of the location is provided on the vehicle of
visiting personnel.
Location: entire store
Original Comment: Install currently serviced 2A-10BC fire extinguishers in an
accessible location 4" to 5 feet above the floor. Fire extinguishers must be located
no further than 75 feet from any location . Fire extinguisher location obstructed
from view must have a fire extinguisher location sign posted above the
obstructions.
Printed on 04/08/2024 @ 11:19
Page 5of7
STATUS CODE DESCRIPTION
FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
Location: all fire extinguishers
Original Comment: provide annual service for all fire extinguishers. Currently
extinguishers have not been serviced since 2018.
GENERAL NOTES
JEFF SIEBEL - 04/08/2024 @ 11:01 annual inspection $80
REINSPECTION DATE
04/29/2024
CONTACT SIGNATURE
Terry Roeder
Signed on: 04/08/2024 @ 11:03
Printed on 04/08/2024 @ 11:19