Loading...
HomeMy WebLinkAbout1022 ALABAR AVECustomer #: 4134 CALICO HEN HOUSE 1022 ALABAR PLAZA WATERLOO, IA 50701 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 05/02/2024 06/10/2024 2024-00000321 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1022 ALABAR AVE - 4-3-24 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 4134 05/02/2024 06/10/2024 2024-00000321 $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT CALICO HEN HOUSE, 1022 ALABAR AVE, BLDG 1022 ALABAR AVE, WATERLOO /A 50701 DETAILS Inspection Date: 04/03/2024 j Inspection Type: Annual Inspection (1 Unit: N/A ' Lead Inspector: JEFF SIEBEL Other Inspectors: N/A VIOLATIONS AND COMPLIANCES • Number: 1142 Shift: N/A j Station: N/A Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 16 I Violations: 10 1 N/A Codes: 49 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: 1014 front exit Original Comment: repair exit/egress light FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: rear exit 1014 Original Comment: repair exit/egress light FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: basement second exit Original Comment: repair exit/egress light Printed on 04/08/2024 @ 11:19 Page 1 of 7 STATUS CODE DESCRIPTION FAIL 315.3.2 - Means of egress. Combustible materials shall not be stored in exits or enclosures for stairways and ramps. Combustible materials in the means of egress during construction, demolition, remodeling or alterations shall comply with Section 3312.3. FAI L 315.3.3 - Equipment rooms. Location: main store and 1014 Original Comment: remove obstructions in exit path to back doors. Maintain a minimum of 36" clearance at all times and any storage must be stable and secure. Combustible material shall not be stored in boiler rooms, mechanical rooms, electrical equipment rooms or in fire command centers as specified in Section 508.1.5. Location: furnace rooms Original Comment: remove all combustible storage from equipment rooms other than maintenance items for equipment in the rooms. Printed on 04/08/2024 @ 11:19 Page 2 of 7 STATUS CODE DESCRIPTION FAIL FAIL 603.2.2 - Unapproved conditionsOpen electrical terminations. 603.4 - Working space and clearancesclearance. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: NE corner of 1014 Original Comment: install outlet cover. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: electrical panels and furnaces Original Comment: remove obstructions . no storage in furnace rooms. Printed on 04/08/2024 @ 11:19 Page 3of7 STATUS CODE DESCRIPTION FAIL 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days. Temporary wiring methods shall meet the applicable provisions of NFPA 70. Exception: Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. Location: entire building Original Comment: Temporary lighting only allowed to be used for 90 days and may not be installed permanently installed. Only exceptions that string lights may be permanently installed if they meet the following criteria: A. Manufacturer specifications allow permanent installations. B. Lights are listed for use indoors. C. Light are installed per listing and manufactureres recommendations. Lights not allowed to be hung by or put strain on wiring. Lights were found to be incorrectly installed with hooks and bent over nails. Printed on 04/08/2024 @ 11:19 Page 4 of 7 STATUS CODE DESCRIPTION FAIL 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10- B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10-pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Location: entire store Original Comment: Install currently serviced 2A-10BC fire extinguishers in an accessible location 4" to 5 feet above the floor. Fire extinguishers must be located no further than 75 feet from any location . Fire extinguisher location obstructed from view must have a fire extinguisher location sign posted above the obstructions. Printed on 04/08/2024 @ 11:19 Page 5of7 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: all fire extinguishers Original Comment: provide annual service for all fire extinguishers. Currently extinguishers have not been serviced since 2018. GENERAL NOTES JEFF SIEBEL - 04/08/2024 @ 11:01 annual inspection $80 REINSPECTION DATE 04/29/2024 CONTACT SIGNATURE Terry Roeder Signed on: 04/08/2024 @ 11:03 Printed on 04/08/2024 @ 11:19 Page 6of7 INS►ECTOR SIGNATURE JEFF SIEBEL Signed on: 04/08/2024 @ 11:15 QUESTIONS A/OUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/08/2024 @ 11:19 Page 7 of 7