COMMERCIAL INSPECTION - 3105 AIRPORT BLVD - 4-18-24
FOR BILLING INQUIRY: (319)291-4323
[ Description
REINSPECTION 1
Total Price ]
$100.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
7485
05/02/2024
06/10/2024
2024-00000319
$100.00
Less Prepayment
Total Due -�
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
WATERLOO TENT & TARP, 3105AIRPORT BLVD, BLDG 3105AIRPORT BLVD, WATERLOO IA
S0703
DETAILS
Inspection Date: 04/18/2024 ! Inspection Type: Annual Inspection (1Yr) Inspection Number: 223 I Shift: N/A ! Station: N/A I
Unit: N/A I Lead Inspector: JEREMIAH VANDYKE I, Other Inspectors: N/A I Fee: $100.00
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 40 I Violations: 8 I N/A Codes: 25
STATUS CODE DESCRIPTION
FAIL
1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in
illumination. accordance with Sections 1008.3 and 1104.5.1.
Location: Entire Building.
Original Comment: Exit and egress lights were tested and failed. Need to repair or
replace by licensed contractor.
FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.
The system shall be capable of powering the required load for a duration of not
less than 90 minutes.
Location: Entire building.
Original Comment: Exit and egress lights were tested and failed. Need to repair or
replace by licensed contractor.
Printed on 04/18/2024 @ 14:55
Page 1 of 5
STATUS CODE DESCRIPTION
FAIL 506.1 - Where required. Where access to or within a structure or an area is restricted because of secured
openings or where immediate access is necessary for life-saving or fire -fighting
purposes, the fire code official is authorized to require a key box to be installed in
an approved location. The key box shall be of an approved type listed in
accordance with UL 1037, and shall contain keys to gain necessary access as
required by the fire code official.
Location: Knox needed on building.
Original Comment: Knox box can be ordered at Knoxbox. com. Please call fire
inspector for where to install or having issues ordering.
FAIL 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and
provide the new key where a lock is changed or rekeyed. The key to such lock
shall be secured in the key box.
FAI L
603.5 - Relocatable power
taps and current
taps.Multiplug adapters.
Location: Master key needed for knoxbox once installed.
Original Comment: Master key needed for knoxbox once installed.
Multiplug adapters, such as cube adapters, unfused plug strips or any other
device not complying with NFPA 70 shall be prohibited. The construction and use
of current taps and relocatable taps shall be in accordance with NFPA 70 and this
code.
Location: Work stations on shop floor.
Original Comment: Extension cords cannot be used as permanent wiring. Or
plugged extension cords plugged into power strips. (No daisy chain of extension
cords or power strips.)
Printed on 04/18/2024 @ 14:55
Page 2of5
STATUS CODE DESCRIPTION
FAIL 603.5.2 - Application and Relocatable power taps and current taps shall be directly connected to a
usePower supply. permanently installed receptacle. Exceptions: 1. Where approved for use in a
Group A occupancy or in a meeting room in a Group B occupancy, not more than
five relocatable power taps shall be permitted to be connected together or
connected to an extension cord for temporary use to supply power to electronic
equipment. 2. Current taps and relocatable power taps shall not be required to
connect directly to a permanently installed receptacle outlet where used for 90
days or less for the purpose of testing the performance of such devices.
FAIL
906.7 - Hangers and brackets.
Location: Upstairs and will check offices/rest of building.
Original Comment: Powerstrips need to be secured and not hanging. Can be
secured with zip ties.
Hand-held portable fire extinguishers, not housed in cabinets, shall be installed
on the hangers or brackets supplied. Hangers or brackets shall be securely
anchored to the mounting surface in accordance with the manufacturer's
installation instructions.
Location: Upstairs.
Original Comment: Re hang fire extinguisher.
Printed on 04/18/2024 @ 14:55
Page 3of5
STATUS CODE DESCRIPTION
FAIL
GENERAL NOTES
Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor
testing, and maintenance
Location: Fire alarm.
Original Comment: I emailed Hawkeye alarm. They do not have any records of an
annual inspection for the fire alarm side. You will need to contact Hawkeye Alarm
to set up a time for an inspection of the system.
JEREMIAH VANDYKE - 04/18/2024 @ 14:28 Fire extinguishers serviced by Proshield August 2023.
JEREMIAH VANDYKE - 04/18/2024 @ 14:28 10/18/2023 S - (Annual) Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC.
Reviewed Compliant
JEREMIAH VANDYKE - 04/18/2024 @ 14:29 11/25/2019 S - 5 Year Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed
Compliant
JEREMIAH VANDYKE - 04/18/2024 @ 14:45 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in
the event of an emergency at that address. Phone # 319-291-2515.
JEREMIAH VANDYKE - 04/18/2024 @ 14:46
Re -inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections & re -inspections are Monday -
Friday, 8:00 a.m. - 5:00 p.m. lithe automatically generated re -inspection date lands on
a weekend, the re -inspection will typically be performed the following Monday or
Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier
re -inspection. *****Re inspection fees may be assessed for subsequent re -
inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent
re-inspections.-
JEREMIAH VANDYKE - 04/18/2024 @ 14:46 Lt. Van Dyke-jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-
1615
JEREMIAH VANDYKE - 04/18/2024 @ 14:46 Inspection Fee = $100.00 (To be mailed out by City via snail mail.)
Printed on 04/18/2024 @ 14:55
Page 4 of 5
REINSPECT/ON DATE
05/18/2024
CONTACT SIGNATURE
Andrea Millang
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on: 04/18/2024 @ 14:47