HomeMy WebLinkAbout1600 OLYMPIC DRCustomer #: 3311 SUNNYSIDE COUNTRY CLUB 1600 OLYMPIC DR WATERLOO, IA 50701 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 03/18/2024 04/20/2024 2024-00000306 $100.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1600 OLYMPIC DR 3-11-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 20.000 OCCUPANCY FEEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 3311 03/18/2024 04/20/2024 2024-00000306 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT SUNNYSIDE COUNTRY CLUB, 1600 OLYMPIC DR, BLD6 1600 OLYMPIC DR, WATERLOO /A S0701 DETAILS Inspection Date: 03/11/2024 I Inspection Type: Annual Inspection (1Yr) I Inspection Number: 10419 Shift: N/A j Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 46 ( Violations: 13 I N/A Codes: 19 STATUS CODE DESCRIPTION FAIL 1010.1 - Doors. Means Doors in the means of egress shall comply with the requirements of Sections 1010.1.1 through 1010.3.4. Exterior exit doors shall meet also comply with the requirements of this section. Doors serving a Section 1022.2. Gates in the means of egress shall comply with the requirements of Sections 1010.4 and 1010.4.1. Turnstiles in the means of egress system shall meet comply with the requirements of this section and Section 1022.2. Doors Sections 1010.5 through 1010.5.4. Doors, gates and turnstiles provided for egress purposes in numbers greater than required by this code shall meet comply with the requirements of this section. Doors in the Means means of egress doors shall be readily distinguishable from the adjacent construction and finishes such that the doors are easily recognizable as doors. Mirrors or similar reflecting materials shall not be used on means of egress doors. Means of egress doors shall not be concealed by curtains, drapes, decorations or similar materials. Location: Golf simulator room Original Comment: Remove curtains and other obstructions to exit doors. Not allowed to disguise exit doors with curtains. Printed on 03/12/2024 @ 10:21 Page 1 of 7 STATUS CODE DESCRIPTION FAIL 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. FAI L FAIL Location: Above parson's trail picture in mezzanine entry Original Comment: repair egress light. 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: upper floor by elevator Original Comment: repair egress light 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in llumination. accordance with Sections 1008.3 and 1104.5.1. Location: Vestibule of Men's locker room exit to long hallway Original Comment: repair egress light FAIL '1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: in hallway outside employees breakroom Original Comment: repair exit light Printed on 03/12/2024 @ 10:21 Page 2of7 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Pro Shop main door Original Comment: repair exit/egress light FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. FAIL 603.2.2 - Unapproved conditionsOpen electrical terminations. Location: entire building including lights listed in violations Original Comment: Provide documentation of testing and repair of all emergency egress and exit lights with signature and date. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Basement walk in cooler Original Comment: replace missing moisture proof cover on light fixture. Printed on 03/12/2024 @ 10:21 Page 3 of 7 STATUS CODE DESCRIPTION FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). FAIL 603.6 - Extension cords. Location: golf cart shed Original Comment: Remove obstructions to electrical panel. maintain a minimum of 36" to and around electrical panels. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: To lamp on piano in foyer Original Comment: remove extension cord Printed on 03/12/2024 @ 10:21 Page 4 of 7 STATUS FAI L CODE 603.6 - Extension cords. DESCRIPTION Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Kitchen office Original Comment: remove extension cord to second desk. Install permanent power with permits and inspections or utilize power tap with reset plugged directly into wall and properly mounted. Printed on 03/12/2024 @ 10:21 Page 5of7 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1 Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: by employees break room in basement Original Comment: replace missing ceiling tiles to enable fire sprinkler to function properly. FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: clubhouse, pro shop, cart shed, maintenance building Original Comment: provide annual service. fire extinguishers month overdue. GENERAL NOTES Printed on 03/12/2024 @ 10:21 Page 6 of 7 JEFF SIEBEL - 03/11 /2024 @ 15:28 Annual inspectio REINSPECT/ON DATE 04/01/2024 CONTACT SIGNATURE Seth Henricks Signed on: 03/12/2024 @ 10:19 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 03/12/2024 @ 10:19 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 03/12/2024 @ 10:21 Page 7 of 7