Loading...
HomeMy WebLinkAbout1819 LA PORTE RDCustomer #: 5404 TACO BELL 7915 KENSINGTON COURT BRIGHTON, MI 48116 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/26/2024 03/28/2024 2024-00000293 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1819 LA PORTE RD - 2-22-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price j $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 5404 02/26/2024 03/28/2024 2024-00000293 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT TACO BELL, 1819 LA PORTE RD, BLDG 1819 LA PORTE RD, WATERLOO IA 50702 DETAILS Inspection Date: 02/22/2024 I Inspection Type: Annual Inspection (1Yr) ; Inspection Number: 12180 j Shift: N/A j Station: N/A j Unit: N/A I Lead Inspector: JEREMIAH VANDYKE I Other Inspectors: N/A ; Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 31 I Violations: 6 I N/A Codes: 36 STATUS CODE DESCRIPTION FAIL 305.1 - Clearance from Clearance between ignition sources, such as luminaires, heaters, flame - ignition sources. producing devices and combustible materials, shall be maintained in an approved manner. Location: Water heater. Original Comment: Maintain 3 feet clear around water heater. FAIL 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. Location: Knox Box. Original Comment: I will check knox box for proper master key for building. Will contact business if key does not work. FAIL 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Location: Commercial Kitchen Exhaust cleaning Original Comment: Commercial Kitchen Exhaust cleaning is past due according to Compliance engine website. Contractor needs to upload report if completed. Printed on 02/22/2024 @ 15:03 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 904.13.5.2 - Extinguishing Automatic fire -extinguishing systems shall be serviced not less frequently than system service. every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. Location: Kitchen Hood ansul system Original Comment: Commercial Hood suppression system is past due according to Compliance engine website. Contractor needs to upload report if completed. FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: All fire extinguishers Original Comment: All fire extinguishers are past due and need to be serviced then tagged. Printed on 02/22/2024 @ 15:03 Page 2 of 4 STATUS CODE DESCRIPTION FAIL GENERAL NOTES 906.4.2 - Class K portable fire Where hazard areas include deep fat fryers, listed Class K portable fire extinguishers for deep fat extinguishers shall be provided as follows: 1.For up to four fryers having a fryers. maximum cooking medium capacity of 80 pounds (36.3 kg) each: one Class K portable fire extinguisher of a minimum 1.5-gallon (6 L) capacity. 2.For every additional group of four fryers having a maximum cooking medium capacity of 80 pounds (36.3 kg) each: one additional Class K portable fire extinguisher of a minimum 1.5-gallon (6 L) capacity shall be provided. 3.For individual fryers exceeding 6 square feet (0.55 m2) in surface area: Class K portable fire extinguishers shall be installed in accordance with the extinguisher manufacturer's recommendations. Location: Class K Extinguisher Original Comment: Class K fire extinguisher is past due and needs to serviced then tagged. JEREMIAH VANDYKE - 02/22/2024 @ 15:01 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone # 319-291-2515. JEREMIAH VANDYKE - 02/22/2024 @ 15:01 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re - inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 02/22/2024 @ 15:01 Lt. Van Dyke-jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883- 1615 JEREMIAH VANDYKE - 02/22/2024 @ 15:02 Inspection Fee = $80.00 REINSPECT/ON DATE 03/23/2024 Printed on 02/22/2024 @ 15:03 Page 3 of 4 CONTACT SIGNATURE Rose S - District Manager Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 02/22/2024 @ 15:02 QUESTIONSAEOUT TOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available 7.t Printed on 02/22/2024 @ 15:03 Page 4 of 4