Loading...
HomeMy WebLinkAbout735 LOGAN AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/26/2024 03/28/2024 2024-00000294 $80.00 Customer #: 14476 LOGAN CONVIENCE STORE 735 LOGAN AV WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 735 LOGAN AVE - 2-19-24 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price ] $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 14476 02/26/2024 03/28/2024 2024-00000294 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT LO6AN CONVENIENCE STORE, 735 LO6ANAVE, BLDG 735 LOGANAVE, WATERLOO IA 50703 DETAILS I ulLP (4) Inspection Date: 02/19/2024 J Inspection Type: Annual Inspection (1Yr) I Inspection Number: 9185 ; Shift: N/A Station: Station 'I Fire Headquarters I Unit: N/A I Lead Inspector: JEFF SIEBEL ( Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 1 Passed Codes: 24 I Violations: 5 I N/A Codes: 44 STATUS CODE DESCRIPTION FAIL 305.1 - Clearance from Clearance between ignition sources, such as luminaires, heaters, flame - ignition sources. producing devices and combustible materials, shall be maintained in an approved manner. Location: storage room on shelf Original Comment: remove storage from 36" clearance around water heater. FAIL 315.3.1 - Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. Exceptions: 1.The 2- foot (610 mm) ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings. 2.The 18-inch (457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. Location: back storage room Original Comment: lower storage away from ceiling Printed on 02/19/2024 @ 15:11 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: back storage room Original Comment: remove obstructions to electric panel. maintain a minimum of 36" clearance at all times. FAIL 603.9.4 - Prohibited areas. Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Location: behind counter Original Comment: remove heater or provide documentation of listing for use in a commercial property and proper clearances. Printed on 02/19/2024 @ 15:11 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. REINSPECT/ON DATE 03/19/2024 CONTACT SIGNATURE Muhammad Bhatti Signed on: 02/19/2024 @ 15:10 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/19/2024 @ 15:10 Location: by front door Original Comment: provide annual service for fire extinguisher. c < C Printed on 02/19/2024 @ 15:11 Page 3 of 4 QUESTIONS ADOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/19/2024 @ 15:11 Page 4of4