Loading...
HomeMy WebLinkAbout3280 UNIVERSITY AVEINVOICE DATE DUE DATE INVOICE # ' TOTAL DUE 02/14/2024 03/20/2024 2024-00000285 $80.00 Customer #: 24327 MIKE'S DINER 3280 UNIVERSITY AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3280 UNIVERSITY AVE - 2-5-24 L Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 24327 BILLING DATE 02/14/2024 DUE DATE 03/20/2024 INVOICE # 2024-00000285 CHARGES Less Prepayment Total Due —> City of Waterloo $80.00 $0.00 S80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT MIKES DINER, 3280 UNIVERSITYAVE, BLDG 3280 UNIVERSITYAVE, WATERLOO /A 50701 DETAILS Inspection Date: 02/05/2024 I Inspection Type: Annual Inspection (1Yr) j Inspection Number: 11720 ! Shift: N/A I Station: N/A Unit: N/A j Lead Inspector: JEFF SIEBEL j Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 41 I Violations: 10 I N/A Codes: 23 STATUS CODE DESCRIPTION FAIL 1004.9 - Posting of occupant Every room or space that is an assembly occupancy shall have the occupant load load. of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space, for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. Location: Not Provided Original Comment: Install occupant load sign provided by fire inspector after all furniture in place. FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: water heater Original Comment: Obtain plumbing permit and inspections for water heater installation. Printed on 02/06/2024 @ 08:53 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: North exit door Original Comment: repair exit/egress sign on back door. FAIL 304.3.1 - Spontaneous Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in ignition. a listed disposal container. Contents of such containers shall be removed and disposed of daily. Location: Not Provided Original Comment: provide listed approved oily waste receptacle for all oily waste rags. See attached. FAIL 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. Location: Not Provided Original Comment: Update knox box keys with fire department. FAIL 509.1 - Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves, or other fire detection, suppression or control elements fire protection systems shall be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Location: outside access to fire sprinkler riser room Original Comment: Install permanent red sign with white letters stating" Fire Sprinkler Riser Room" on door to access door. Printed on 02/06/2024 @ 08:53 Page 2of5 STATUS CODE DESCRIPTION FAIL 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: entry way and ceiling Original Comment: Provide covers for all outlet and switch boxes as well as install covers on all junction boxes. FAIL 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: Dining area to new TVs Original Comment: Install permanent outlets below the ceiling for TV's with proper permits and inspections. FAIL 603.9.4 - Prohibited areas. Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Location: fire sprinkler room Original Comment: remove portable electric heater from fire sprinkler room and install permanent heat to maintain 45 deg in fire sprinkler riser room . Printed an 02/06/2024 @ 08:53 Page 3 of 5 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERAL NOTES JEFF SIEBEL - 02/06/2024 @ 08:50 JEFF SIEBEL - 02/06/2024 @ 08:51 JEFF SIEBEL - 02/06/2024 @ 08:51 REINSPECT/ON DATE 02/21/2024 CONTACT SIGNATURE Mike Noel Signed on: 02/06/2024 @ 08:51 Location: entire store and kitchen Original Comment: re -install missing ceiling tile. annual inspection $80 escutcheon replaced during inspection. call for re -inspection if completed early. Printed on 02/06/2024 @ 08:53 Page 4of5 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/06/2024 @ 08:52 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/06/2024 @ 08:53 Page 5 of 5