Loading...
HomeMy WebLinkAbout2843 ANSBOROUGH AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/14/2024 03/20/2024 2024-00000272 $100.00 Customer #: 20752 HY-VEE #1 2834 ANSBOROUGH AV WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2834 ANSBOROUGH AVE - 2-1-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 20,000 OCCUPANCY FEE Total Price ] $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 20752 02/14/2024 03/20/2024 2024-00000272 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT HY-VEE, 2834ANSBOR000HAVE, BLDG2S34ANSBOR000HAVE, WATERLOO /A S0701 DETAILS Inspection Date: 02/01/2024 I Inspection Type: Annual Inspection (1Yr) 1 Inspection Number: 9804 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A 1 Fee: $100.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 43 I Violations: 10 I N/A Codes: 25 STATUS CODE DESCRIPTION Printed on 02/05/2024 @ 08:30 Page 1 of 7 FAIL 1010.2.13.1 - Delayed egress The delayed egress locking system shall be installed and operated in accordance locking system. with all of the following: 1.The delay electronics of the delayed egress locking system shall deactivate upon actuation of the automatic sprinkler system or automatic fire detection system, allowing immediate, free egress. 2.The delay electronics of the delayed egress locking system shall deactivate upon loss of power controlling the lock or lock mechanism, allowing immediate free egress. 3.The delayed egress locking system shall have the capability of being deactivated at the fire command center and other approved locations. 4.An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware for not more than 3 seconds. Initiation of the irreversible process shall activate an audible signal in the vicinity of the door. Once the delay electronics have been deactivated, rearming the delay electronics shall be by manual means only. Exception: Where approved, a delay of not more than 30 seconds is permitted on a delayed egress door. 5.The egress path from any point shall not pass through more than one delayed egress locking system. Exceptions: 1.In Group 1-1, Condition 2, Group 1-2 or 1-3 occupancies, the egress path from any point in the building shall pass through not more than two delayed egress locking systems provided that the combined delay does not exceed 30 seconds. 2.In Group 1-1, Condition 1 or Group 1-4 occupancies, the egress path from any point in the building shall pass through not more than two delayed egress locking systems provided that the combined delay does not exceed 30 seconds and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. 6.A sign shall be provided on the door and shall be located above and within 12 inches (305 mm) of the door exit hardware: Exception: Where approved, in Group I occupancies, the installation of a sign is not required where care recipients who, because of clinical needs, require restraint or containment as part of the function of the treatment area. 6.1.For doors that swing in the direction of egress, the sign shall read: "PUSH UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 [30] SECONDS." 6.2.For doors that swing in the opposite direction of egress, the sign shall read: "PULL UNTIL ALARM SOUNDS. DOOR CAN BE OPENED IN 15 [30] SECONDS." 6.3.The sign shall comply with the visual character requirements in ICC A117.1.7.Emergency lighting shall be provided on the egress side of the door. 8.The delayed egress locking system units shall be listed in accordance with UL 294. Location: walk thru dock door Original Comment: Provide documentation of fire alarm release of door. Repair Mag release , currently door does not release after 15 seconds. Printed on 02/05/2024 @ 08:30 Page 2 of 7 STATUS CODE DESCRIPTION FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Location: Entire Store Original Comment: provide documentation of emergency egress/exit lights with all discrepancies corrected with signature and date. FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Location: Generator engine service and load bank test Original Comment: Provide current generator engine service and load bank test inspection report. FAIL 305.1 - Clearance from Clearance between ignition sources, such as luminaires, heaters, flame - ignition sources. producing devices and combustible materials, shall be maintained in an approved manner. Location: under stairs from upper level to dock area Original Comment: remove combustibles from charger under stairs. Printed on 02/05/2024 @ 08:30 Page 3 of 7 STATUS CODE DESCRIPTION FAIL 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. FAI L FAI L 603.9.4 - Prohibited areas. Location: Fire sprinkler riser by back door. Original Comment: Remove obstructions. (snow blower) maintain a minimum of 36" clearance at all times Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Location: Upstairs office and department head office Original Comment: remove portable electric heaters or provide documentation of listing for commercial use and proper clearances.. 606.3.3.2 - Grease If during the inspection it is found that hoods, grease -removal devices, fans, accumulation. ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSI/IKECA C10. Location: Asian Kitchen Original Comment: Clean oily filters above appliances. Excessive grease drips fueling the fire. Printed on 02/05/2024 @ 08:30 Page 4 of 7 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the fisting criteria and manufacturer's installation instructions. Location: dining room Original Comment: Replace missing ceiling tile FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: upper club room Original Comment: replace missing ceiling tile. Printed on 02/05/2024 @ 08:30 Page 5 of 7 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERAL NOTES JEFF SIEBEL - 02/02/2024 @ 19:15 JEFF SIEBEL - 02/02/2024 @ 19:15 REINSPECTION DATE 02/26/2024 CONTACT SIGNATURE Ashley Jones Signed on: 02/02/2024 @ 19:22 Location: IN Fruit room Original Comment: replace missing ceiling tile annual inspection $100 Fire extinguishers are due in March. sl/)laj Printed on 02/05/2024 @ 08:30 Page 6of7 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/02/2024 @ 19:22 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/05/2024 @ 08:30 Page 7of7