Loading...
HomeMy WebLinkAbout2450 CROSSROADS BLVDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 02/14/2024 03/20/2024 2024-00000275 $235.00 Customer #: 13032 CROSSROADS 12 THEATRES 2450 CROSSROADS BLVD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2450 CROSSROADS BLVD - 2-8-24 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 50,000 OCCUPANCY FEE Total Price ] $225.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 13032 02/14/2024 03/20/2024 2024-00000275 $235.00 Less Prepayment Total Due —> City of Waterloo $0.00 $235.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT MARCUS THEATERS, 2450 CROSSROADS BLVD, BLDG 2450 CROSSROADS BLVD, WATERLOO IA 50702 DETAILS Inspection Date: 02/08/2024 1 Inspection Type: Annual Inspection (1Yr) 1 Inspection Number: 9970 I Shift: N/A Station: N/A 1 Unit: N/A j Lead Inspector: JEFF SIEBEL 1 Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 1 Passed Codes: 44 1 Violations: 9 1 N/A Codes: 22 STATUS CODE DESCRIPTION FAIL 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch - pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Location: outside exit by theater 3. Original Comment: Repair exit door. Must unlatch and swing to full open with less than 15# force. Printed on 02/08/2024 @ 09:11 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. FAI L FAIL Location: Not Provided Original Comment: Emergency light testing by Brandon Kline completed 1/25/24 lists deficiencies. Provide documentation of corrections with signature and date or invoice. 2015 IFC - Fire alarm testing Is the fire alarm system powered, operational and displaying normal operation and maintenance (no troubles, supervisory, or alarms)? Location: Not Provided Original Comment: Fire alarm panel displays trouble. Provide corrections 5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection Location: Not Provided Original Comment: Fire Sprinkler inspection from 12/28/23 lists discrepancies. Contractor must upload corrections online to the compliance engine. Printed on 02/08/2024 @ 09:11 Page 2of5 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Theater 1 Original Comment: Replace missing ceiling tile. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Theater 9 Original Comment: Replace theater 9 Printed on 02/08/2024 @ 09:11 Page 3 of 5 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Storage room by Men's restroom and theater 1 Original Comment: replace missing ceiling tile. FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Entire building Original Comment: fire extinguishers due now Printed on 02/08/2024 @ 09:11 Page 4of5 STATUS CODE DESCRIPTION FAIL Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor testing, and maintenance Location: Not Provided Original Comment: Provide current fire alarm inspection report with all discrepancies corrected. Currently past due. Contractor must upload online to the compliance engine. GENERAL NOTES JEFF SIEBEL - 02/08/2024 @ 09:07 annual inspection $235 REINSPECTION DATE 02/28/2024 CONTACT SIGNATURE Brandon Kline manager 2023 Signed on: 02/08/2024 @ 09:08 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 02/08/2024 @ 09:08 QUESTIONS ADOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 K- e_c./ /,,, ii/-1,---Lce 0 .----, Printed on 02/08/2024 @ 09:11 Page 5 of 5