Loading...
HomeMy WebLinkAbout51 E TOWER PARK DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/25/2024 02/28/2024 2024-00000254 $80.00 Customer #: 13774 CASEY'S GENERAL STORE #2866 1 SE CONVENIENCE BLVD ANKENY, IA 50021 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 51 E TOWER PARK DR - 1-18-24 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Tota Price J $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 13774 01/25/2024 02/28/2024 2024-00000254 $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT CASEY'S GENERAL STORE #2866, 51 E TOWER PARK DR, BLDG 51 E TOWER PARK DR WATERLOO IA S0702 DETAILS Inspection Date: 01/18/2024 ; Inspection Type: Annual Inspection (1Yr) Inspection Number: 10013 i Shift: N/A I Station: N/A Unit: N/A j Lead Inspector: JEFF SIEBEL ' Other Inspectors: N/A I Fee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 36 I Violations: 3 I N/A Codes: 34 STATUS CODE DESCRIPTION FAIL 305.1 - Clearance from Clearance between ignition sources, such as luminaires, heaters, flame - ignition sources. producing devices and combustible materials, shall be maintained in an approved manner. Inspector: JEFF SIEBEL - Comments: remove storage by water heater especially bag of rags . Maintain a minimum of 36" clearance at all times. Location: Back room by water heater FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Inspector: JEFF SIEBEL - Comments: Maintain a minimum of 36" clearance to electric panels at all times. top to floor Location: back room Printed on 01/23/2024 @ 09:09 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining protection. GENERAL NOTES JEFF SIEBEL - 01/23/2024 @ 09:06 JEFF SIEBEL - 01/23/2024 @ 09:06 REINSPECTION DATE 02/08/2024 CONTACT SIGNATURE Melissa Scmidt Signed on: 01/23/2024 @ 09:07 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector: JEFF SIEBEL - Comments: replace missing ceiling tiles. Location: back room by water heater annual inspection $80 Kitchen hood cleaning due 2/14/24 Printed on 01/23/2024 @ 09:09 Page 2 of 3 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 01/23/2024 @ 09:07 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/23/2024 @ 09:09 Page 3of3