Loading...
HomeMy WebLinkAbout213 E 5TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/02/2024 02/05/2024 2024-00000235 $80.00 Customer #: 23164 THE COMFORT ZONE 213 E 5TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 213 E 5TH ST - 12-8-23 L Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price j $70.00 $10.00 CUSTOMER # BILLINGDATE DUE DATE INVOICE # 23164 01/02/2024 02/05/2024 2024-00000235 CHARGES $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT THE COMFORT ZONE, 213 E STH ST, BLDG 213 -219 E STH ST, WATERLOO /A S0703 DETAILS Inspection Date: 12/08/2023 ( Inspection Type: Annual Inspection (1Yr) Inspection Number: 11516 ; Shift: N/A ; Station: N/A j Unit: N/A ; Lead Inspector: JEREMIAH VANDYKE ( Other Inspectors: N/A I Fee: $80.00 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector: JEREMIAH VANDYKE - Comments: Rear exit/egress light tested and failed. Will send pic. Location: Rear exit FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector: JEREMIAH VANDYKE - Comments: Missing ceiling tile. Will send pic. Location: Kitchen Printed on 12/08/2023 @ 13:44 Page 1 of 3 STATUS CODE FAIL 906.2 - General requirements. GENERAL NOTES JEREMIAH VANDYKE DESCRIPTION Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector: JEREMIAH VANDYKE - Comments: Fire extinguisher tag is passed due and needs to be serviced then retagged. Will send pic. Location: Fire extinguisher behind bar - 12/08/2023 @ 13:37 07/09/2023 S - (Semi -Annual) Kitchen Exhaust AKA SERVICES INC. Reviewed Compliant JEREMIAH VANDYKE - JEREMIAH VANDYKE - 12/08/2023 @ 13:41 12/08/2023 @ 13:42 JEREMIAH VANDYKE - 12/08/2023 @ 13:42 JEREMIAH VANDYKE - 12/08/2023 @ 13:36 JEREMIAH VANDYKE - 12/08/2023 @ 13:42 Will send pictures of corrected violations. Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re - inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- Lt. Van Dyke-jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883- 1615 10/02/2023 S - Kitchen Hood Suppression SUPERIOR FIRE PROTECTION EQUIPMENT Reviewed Compliant Inspection Fee = $80.00 Printed on 12/08/2023 @ 13:44 Page 2 of 3 REINSPECTION DATE 01/07/2024 CONTACT SIGNATURE Tommy Mccelllan-bey INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 12/08/2023 @ 13:42 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Reason for not collecting a signature: NA 9 A Printed on 12/08/2023 @ 13:44 Page 3 of 3