Loading...
HomeMy WebLinkAbout2035 E MITCHELL AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/02/2024 02/05/2024 2024-00000231 $100.00 Customer #: 23182 KING STAR 2035 EAST MITCHELL WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2035 E MITCHELL AVAE - 12-15-23 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION 1 Total Price $100.00 CUSTOMER # 23182 BILLING DATE 01/02/2024 DUE DATE 02/05/2024 INVOICE # 2024-00000231 CHARGES $100.00 Less Prepayment Total Due City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT KIND STAR, 2035 E MITCHELL AVE, BLD6 2035 E MITCHELL AVE, WATERLOO IA 50702 DETAILS Inspection Date: 12/15/2023 Inspection Type: Annual Inspection (1Yr) j Inspection Number: 11462 I Shift: N/A I Station: N/A I Unit: N/A I Lead Inspector: JEREMIAH VANDYKE I Other Inspectors: JEFF SIEBEL I Fee: $100.00 VIOLATIONS AND COUPLâ–ºANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 0 I Violations: 7 I N/A Codes: 0 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector: JEREMIAH VANDYKE - Comments: repair exit light above main door Location: Main door FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector: JEREMIAH VANDYKE - Comments: Repair exit light above door. Location: Side door to the west Printed on 12/15/2023 @ 13:13 Page 1 of 5 STATUS CODE DESCRIPTION FAI L FAIL 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Inspector: JEREMIAH VANDYKE - Comments: properly secure compressed gas cylinder with chain. Location: Not Provided 603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions and electrical conditions in permanent wiring shall be brought to the attention of the hazards. responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector: JEREMIAH VANDYKE - Comments: remove or properly contain all electrical wiring outside in front soffit in accordance with electrical codes. Location: Front soffit Printed on 12/15/2023 @ 13:13 Page 2of5 STATUS CODE DESCRIPTION FAIL 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Inspector: JEREMIAH VANDYKE - Comments: properly mount power strip by gas controller in back room. May not hang by cords. Location: Near gas controller in back room. FAIL 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10- B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10-pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector: JEREMIAH VANDYKE - Comments: replace missing fire extinguisher next to side door. Location: near side door Printed on 12/15/2023 @ 13:13 Page 3of5 STATUS CODE DESCRIPTION FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. GENERAL NOTES JEREMIAH VANDYKE - 12/15/2023 @ 13:11 Inspector: JEREMIAH VANDYKE - Comments: Provide annual service for all fire extinguishers. expired 2020 Location: Not Provided Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re - inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 12/15/2023 @ 13:11 Lt. Van Dyke-jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883- '1615 JEREMIAH VANDYKE -12/15/2023 @ 13:11 Nothing was corrected on visit. RE - Inspection Fee = $100.00 REINSPECTION DATE 01/14/2024 Printed on 12/15/2023 @ 13:13 Page 4 of 5 CONTACT SIGNATURE Sue - Store Clerk INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 12/15/2023 @ 13:13 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Reason for not collecting a signature: NA Printed on 12/15/2023 @ 13:13 Page 5 of 5