Loading...
HomeMy WebLinkAbout2034 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/02/2024 02/05/2024 2024-00000228 $100.00 Customer #: 12855 HAMPTON INN 2034 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2034 LA PORTE RD - 12-6-23 L Description FOR BILLING INQUIRY: (319)291-4323 REINSPECTION 1 Total Price ] $100.00 CUSTOMER # 12855 BILLING DATE 01/02/2024 DUE DATE 02/05/2024 INVOICE # 2024-00000228 CHARGES Less Prepayment Total Due —� City of Waterloo $100.00 $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT HAMPTON INN & SUITES, 2034 LA PORTE RD, BLDG 2034 LA PORTE RD, WATERLOO IA 50702 DETAILS Inspection Date: 12/06/2023 I Inspection Type: Annual Inspection (1Yr) Inspection Number: 11521 Shift: N/A ; Station: N/A j Unit: N/A j Lead Inspector: JEFF SIEBEL Other Inspectors: N/A ( Fee: $100.00 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the International code. Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Inspector: JEFF SIEBEL - Comments: Obtain permit and final inspection for new fire door for pool chemical room Location: Fire Door Pool Chemical Room FAIL 102.4 - Application of building The design and construction of new structures shall comply with the International code. Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Inspector: JEFF SIEBEL - Comments: Obtain permit and inspections for repair of fire rated ceiling. Location: Hall outside restrooms on first floor FAIL 102.4 - Application of building The design and construction of new structures shall comply with the International code. Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Inspector: JEFF SIEBEL - Comments: Obtain final inspection for sheetrock repairs in fire rated walls and ceiling. Location: Maids closet and 1st floor ceiling Printed on 12/07/2023 @ 10:13 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the International code. Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Inspector: JEFF SIEBEL - Comments: Obtain permits and inspections for new water heater installations. Location: Water heaters room on first floor FAIL 2015 IFC- Fire alarm testing Is the fire alarm system powered, operational and displaying normal operation (no and maintenance troubles, supervisory, or alarms)? Inspector: JEFF SIEBEL - Comments: Smoke Detector must be secured to ceiling. Location: Room 409 FAIL 2015 IFC - Fire alarm testing Is the fire alarm system powered, operational and displaying normal operation (no and maintenance troubles, supervisory, or alarms)? Inspector: JEFF SIEBEL - Comments: secure smoke detector to ceiling. Location: room 301 FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Inspector: JEFF SIEBEL - Comments: Remove obstructions to electrical panel. Maintain a minimum of 36" clearance at all times. Location: maid closet by room 400 Printed on 12/07/2023 @ 10:13 Page 2of5 STATUS CODE DESCRIPTION FAIL 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector: JEFF SIEBEL - Comments: Provide documentation of dryer vent cleaning to the outside of the building with signature and date. Remove excess lint from bottom motors of commercial dryers. repair pipe on guest dryer. Location: Commercial Dryers and guest dryers FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector: JEFF SIEBEL - Comments: Repair sheetrock ceiling above dropped ceiling(fire rated) with permit and inspections. Location: Outside restrooms in hall ceiling FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Inspector: JEFF SIEBEL - Comments: Fire Door must completely self close and latch Location: 4th floor elevator fire door FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Inspector: JEFF SIEBEL - Comments: Door must completely self -close and latch Location: room 407 Printed on 12/07/2023 @ 10:13 Page 3of5 STATUS CODE DESCRIPTION FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Inspector: JEFF SIEBEL - Comments: Fire door must completely self close and latch Location: Door between condiment room and kitchen FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Inspector: JEFF SIEBEL - Comments: Fire door must completely self -close and latch. Location: room 129 GENERAL NOTES JEFF SIEBEL - 12/07/2023 @ 10:09 Items rolled over from last years inspection: Fire door permits and inspections still required and final inspection on sheetrock and doors required. Re -inspection fee of $200 will resume if not completed. JEFF SIEBEL -12/07/2023 @ 10:08 Annual inspection fee $100 REINSPECTION DATE 12/28/2023 CONTACT SIGNATURE Mitch Goodrich - Maintenance Signed on: 12/07/2023 @ 10:10 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 12/07/2023 @ 10:10 Printed on 12/07/2023 @ 10:13 Page 4 of 5 QUESTIONS AMOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 12/07/2023 @ 10:13 Page 5of5