Loading...
HomeMy WebLinkAbout710 JEFFERSON STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/02/2024 02/05/2024 2024-00000226 $80.00 Customer #: 23382 THE LOFT 710 JEFFERSON ST #4 WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 710 JEFFERSON ST - 12-4-23 L Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price j $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23382 01/02/2024 02/05/2024 2024-00000226 $80.00 Less Prepayment Total Due —4 City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT THE LOFT, 710JEFFERSON ST, BLDG 710JEFFERSON ST - STE UPPER FLOOR, WATERLOO IA 50701 DETAILS Inspection Date: 12/04/2023 Inspection Type: Annual Inspection (1 Yr) Inspection Number: 9524 j Shift: N/A ( Station: N/A Unit: N/A ! Lead Inspector: JEFF SIEBEL j Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector: JEFF SIEBEL - Comments: repair egress light Location: By pool table above woodchuck sign FAIL 4.9 - Support of nonsprinkler Sprinkler system components shall not be used to support non -sprinkler system system components components unless expressly permitted by NFPA 13. Inspector: JEFF SIEBEL - Comments: remove all wires and other items from fire sprinkler pipes and hangers. Location: front street side of the bar. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturers installation instructions. GENERAL NOTES Inspector: JEFF SIEBEL - Comments: remove drop down hold open device from fire door. Door must remain dosed at all times or held open with a fire alarm controlled device. Location: Top of West stairway Printed on 12/07/2023 @ 10:54 Page 1 of 2 JEFF SIEBEL - 12/07/2023 @ 10:47 JEFF SIEBEL - 12/07/2023 @ 10:47 REINSPECTION DATE 01/16/2024 CONTACT SIGNATURE Christopher "Bud" Jones Signed on: 12/07/2023 @ 10:51 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 12/07/2023 @ 10:51 QUESTIONS AEOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 annual inspection fee $80 Fire Alarm inspection due 12/8/23. Printed on 12/07/2023 @ 10:54 Page 2of2