RENTAL INSPECTION - 612 RHEY ST - 11-29-23
[Description
FOR BILLING INQUIRY: (319)291-4323
REINSPECTION FEE 3RD
Total Price J
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
23528
11/30/2023
12/31/2023
2024-00000118
$250.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
DJS PROPERTIES LLC 3 FAMILY CONVERSION, 612 RHEY ST, WATERLOO IA S0703
DETAILS
Inspection Date: 11/29/2023 I Inspection Type: Rental Inspection I Inspection Number: 11338 I S ift: N/A I Station: N/A I
Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00/^ n
STATUS CODE
FAIL 1010.1.9 - Door operations
SCRIP ON
Except as specifically permitted by this section, egress doois shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON - Comments: Front door
Location: Not Provided
FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction, and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars, grilles, grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key, tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON - Comments: Window sills rotten
Location: Not Provided
FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not he used.
Inspector: BARRY STRATTON - Comments: Outlets not grounded and have tension
strength issues. Outlets have grounding pins broken off in outlets. Have outlets
replaced and grounding issues corrected. Globes needed on all light. Light in living
room has exposed wires.
Location: Not Provided
Primes or. 'i _129 2•O23 r- 2'4
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm)
of commercial cooking equipment. 3. In areas where flammable or combustible
liquids are stored, used or dispensed. 4. On each floor of structures under
construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1. 6. Special -hazard areas,
including but not limited to laboratories, computer rooms and generator rooms,
where required by the fire code official.
FAIL 907.2.11 - Single- and
multiple -station smoke
alarms
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
Listed single- and multiple- station smoke alarms complying with UL 217 shall be
installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
Inspector: BARRY STRATTON - Comments: No smoke detectors installed in unit # 1
Location: Not Provided
FAIL 915.1 - General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915. 6. Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103,9.
Inspector: BARRY STRATTON - Comments: CO detectors needed
Location: Not Provided
FAIL RS - Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and
sanitary state? (IPMC 304)
Inspector: BARRY STRATTON - Comments: Front porch has supports that are failing.
Front stairs are rotten and need replaced. Holes in porch floor need corrected.
Apartment door to # 1 needs replaced since door has been broken and split at lock
sets New stairs installed do not meet code.
Location: Front of building.
FAIL R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
Print atl on t 1 /29/2023 :: ! -':14
Page 2 of 4
STATUS CODE DESCRIPTION
Inspector: BARRY STRATTON - Comments: Floors, carpet stained, floor has several
dips from supports in basement failing. Holes in walls, rotten window sills in
bedroom, screen damaged, register vents not in ducts.
Location: Not. Provided
FAIL R6.B. - Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F? (IPMC 602.2)
GENERAL NOTES
BARRY STRATTON - 11/29/2023 @ 12:12
Inspector: BARRY STRATTON - Comments: Register covers
Location: Not Provided
304.10 Stairways, decks, porches and balconies. Every exterior stairway, deck, porch
and balcony, and all appurtenances attached thereto, shall be maintained structurally
sound, in good repair, with proper anchorage and capable of supporting the imposed
loads.
BARRY STRATTON - 11/29/2023 @ 12:13 304.13 Window, skylight and door frames. Every window, skylight, door and frame shall
be kept in sound condition, good repair and weather tight.
BARRY STRATTON 11/29/2023 @ 12:13
304.15 Doors. Exterior doors, door assemblies, operator systems if provided, and
hardware shall be maintained in good condition. Locks at all entrances to dwelling
units and sleeping units shall tightly secure the door. Locks on means of egress doors
shall be in accordance with Section 702.3
BARRY STRATTON - 11/29/2023 @ 12:13 305.4 Stairs and walking surfaces. Every stair, ramp, landing, balcony, porch, deck or
other walking surface shall be maintained in sound condition and good repair
BARRY STRATTON - 11/29/2023 @ 12:13 304.4 Structural members. Structural members shall be maintained free from
deterioration, and shall be capable of safely supporting the imposed dead and live
loads.
BARRY STRATTON -11/29/2023 @ 12:13 305.3 Interior surfaces. Interior surfaces, including windows and doors, shall be
maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded
paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood
and other defective surface conditions shall be corrected.
Panted on 11129,/2023 12:14
Page 3 of 4
GENERAL NOTES
BARRY STRATTON -11 /29/2023 @ 12:13
REINSPECTION DATE
12/27/2023
CONTACT SIGNATURE
DJS Properties LLC
Signed on: 11/29/2023 @ 12:13
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 11/29/2023 @ 12:13
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319) 231-9147
604.3 Electrical system hazards. Where it is found that the electrical system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service, improper fusing, insufficient receptacle and lighting outlets,
improper wiring or installation, deterioration or damage, or for similar reasons, the
code official shall require the defects to be corrected to eliminate the hazard.