Loading...
HomeMy WebLinkAbout264 BALTIMORE STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/30/2023 12/31/2023 2024-00000116 $250.00 Customer #: 23001 QUALITY CONCRETE CONTRUCTION (RENTAL) 1930 HAWTHORNE AVE #1 WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 264 BALTIMORE ST - 11-27-23 [ Description FOR BILLING INQUIRY: (319)291-4323 REINSPECTION FEE 3RD Total Price $250.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23001 11/30/2023 12/31/2023 2024-00000116 $250.00 Less Prepayment TotalDue —> City of Waterloo $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT QUALITY CONCRETE CONSTRUCTION 4 FAMILY CONVERSION, 264 BAL'. IA S0701 DETAILS l0 "Pc-c ST, WATERLOO Inspection Date: 11/27/2023 I Inspection Type: Rental Inspection { Inspection Number: 11307 I Shi : N/A ! Station: N/A I Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: S250.00 „ J STATUS CODE FAIL 1010.1.9 - Door operations DESCRIPTION Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: Door operation/weatherization, hardware for doors. Location: Not Provided FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON - Comments: Windows screwed shut. Location: Not Provided FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed. 4. On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1. 6. Special -hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON - Comments: None Location: Not Provided Printed an 11/27/2023 fJ 12:09 Page 1 of 3 STATUS CODE DESCR#PT1ON FAIL 907.2.11 - Single- and Listed single- and multiple- station smoke alarms complying with UL 217 shall be multiple -station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON - Comments: Missing smoke detectors. Location: Not Provided FAIL 915.1 - General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915. 6. Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON - Comments: None Location: Not Provided FAIL R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest infestations. (IPMC 302) Inspector: BARRY STRATTON - Comments: Handrails on front stairs still not repaired/replaced. Handrails do not meet code. Location: Not Provided R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) GENERAL NOTES BARRY STRATTON -11 /27/2023 @ 12:08 Inspector: BARRY STRATTON - Comments: Peeling paint, bath ceiling, holes in floors. Broken stairs treads still not replaced. Location: Not Provided 403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated. 264 Baltimore Unit 2 BARRY STRATTON - 11/27/2023 @ 12:08 264 Baltimore St # 3: Toilet needs re -set on floor, entry way ceiling, peeling paint and abraded paint needs corrected. Smoke detectors needed installed to code. Panted on 11/27/2023 =& 12:09 Page 2 of 3 GENERAL NOTES DARRYSTRATTDN 11/37/20330P12:08 264 Baltimore St 4: Smoke detectors need installed to code. install globes on all lights in building. CO Detector BARRYSTKATT0N'11O7/20J@12:08 Smoke detectors missing incommon hallways 109.4 Violation penalties. Any person who shall violate a provision of this code, or fail to comply therewith, or with any of the requirements thereof, shall be prosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall bedeemed aseparate offense BARRYSTRA7TON 11/27/ 023@12/08 9-7'0:DENIAL, SUSPENSION, REVOCATION ORNONRENEVVAL:AlFailure tocorrect deficiencies noted in notices of violation within the tirne specified in the notice. it Is W10N DATE 12/27/ 023 CON TACT SIGNATURE DanReye'aon VN$PECT»R4mO0AMNE BARRY5TRA7TON BARRY5TRATTON ba/ry.snat0on@waeMo*iuurg Printed on,n27co23 ��,—Lm Page 3vr3