HomeMy WebLinkAbout264 BALTIMORE STINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
11/30/2023
12/31/2023
2024-00000116
$250.00
Customer #: 23001
QUALITY CONCRETE CONTRUCTION (RENTAL)
1930 HAWTHORNE AVE #1
WATERLOO, IA 50702
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION - 264 BALTIMORE ST - 11-27-23
[ Description
FOR BILLING INQUIRY: (319)291-4323
REINSPECTION FEE 3RD
Total Price
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
23001
11/30/2023
12/31/2023
2024-00000116
$250.00
Less Prepayment
TotalDue —>
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
QUALITY CONCRETE CONSTRUCTION 4 FAMILY CONVERSION, 264 BAL'.
IA S0701
DETAILS
l0
"Pc-c
ST, WATERLOO
Inspection Date: 11/27/2023 I Inspection Type: Rental Inspection { Inspection Number: 11307 I Shi : N/A ! Station: N/A I
Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: S250.00 „ J
STATUS CODE
FAIL 1010.1.9 - Door operations
DESCRIPTION
Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON - Comments: Door operation/weatherization, hardware
for doors.
Location: Not Provided
FAIL 1031.7 - Emergency escape Required emergency escape and rescue openings shall be maintained in accordance
and rescue openings with the code in effect at the time of construction, and the following: Required
emergency escape and rescue openings shall be operational from the inside of the
room without the use of keys or tools. Bars, grilles, grates or similar devices are
allowed to be placed over emergency escape and rescue openings provided the
minimum net clear opening size complies with the code that was in effect at the time
of construction and such devices shall be releasable or removable from the inside
without the use of a key, tool or force greater than that which is required for normal
operation of the emergency escape and rescue opening.
Inspector: BARRY STRATTON - Comments: Windows screwed shut.
Location: Not Provided
FAIL 906.1 - Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B: C. 2. Within 30 feet (9144 mm)
of commercial cooking equipment. 3. In areas where flammable or combustible
liquids are stored, used or dispensed. 4. On each floor of structures under
construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1. 6. Special -hazard areas,
including but not limited to laboratories, computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
Printed an 11/27/2023 fJ 12:09
Page 1 of 3
STATUS CODE DESCR#PT1ON
FAIL 907.2.11 - Single- and Listed single- and multiple- station smoke alarms complying with UL 217 shall be
multiple -station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON - Comments: Missing smoke detectors.
Location: Not Provided
FAIL 915.1 - General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915. 6. Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON - Comments: None
Location: Not Provided
FAIL R4 - Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This
includes grading and drainage, sidewalks and driveways, weeds, and pest
infestations. (IPMC 302)
Inspector: BARRY STRATTON - Comments: Handrails on front stairs still not
repaired/replaced. Handrails do not meet code.
Location: Not Provided
R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound, and in a sanitary condition? (IPMC 305)
GENERAL NOTES
BARRY STRATTON -11 /27/2023 @ 12:08
Inspector: BARRY STRATTON - Comments: Peeling paint, bath ceiling, holes in floors.
Broken stairs treads still not replaced.
Location: Not Provided
403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with
the ventilation requirements for habitable spaces as required by Section 403.1, except
that a window shall not be required in such spaces equipped with a mechanical
ventilation system. Air exhausted by a mechanical ventilation system from a bathroom
or toilet room shall discharge to the outdoors and shall not be recirculated. 264
Baltimore Unit 2
BARRY STRATTON - 11/27/2023 @ 12:08 264 Baltimore St # 3: Toilet needs re -set on floor, entry way ceiling, peeling paint and
abraded paint needs corrected. Smoke detectors needed installed to code.
Panted on 11/27/2023 =& 12:09
Page 2 of 3
GENERAL NOTES
DARRYSTRATTDN 11/37/20330P12:08 264 Baltimore St 4: Smoke detectors need installed to code. install globes on all lights
in building. CO Detector
BARRYSTKATT0N'11O7/20J@12:08 Smoke detectors missing incommon hallways
109.4 Violation penalties. Any person who shall violate a provision of this code, or fail
to comply therewith, or with any of the requirements thereof, shall be prosecuted
within the limits provided by state or local laws. Each day that a violation continues
after due notice has been served shall bedeemed aseparate offense
BARRYSTRA7TON 11/27/ 023@12/08 9-7'0:DENIAL, SUSPENSION, REVOCATION ORNONRENEVVAL:AlFailure tocorrect
deficiencies noted in notices of violation within the tirne specified in the notice.
it
Is
W10N DATE
12/27/ 023
CON TACT SIGNATURE
DanReye'aon
VN$PECT»R4mO0AMNE
BARRY5TRA7TON
BARRY5TRATTON
ba/ry.snat0on@waeMo*iuurg
Printed on,n27co23 ��,—Lm
Page 3vr3