Loading...
HomeMy WebLinkAbout200-255 PARK VIEW BLVDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/19/2023 08/20/2023 2024-00000022 $50.00 Customer #: 24063 PARKVIEW BLDG LLC 309 E 4TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 200-255 PARK VIEW BLVD - 6-13-23 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER # 24063 BILLING DATE 07/19/2023 DUE DATE 08/20/2023 INVOICE # 2024-00000022 CHARGES $50.00 Less Prepayment Total Due —> City of Waterloo $0.00 $50.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ATERLOO FIRE RESCUE INSPECTION REPORT PARK VIEW APARTMENTS, 200-255 PARK VIEW BLVD, WATER DETAILS �'Wdyosi101t vsa �W 0 IA 50702 ct"h` ,a,,063 6°1- Inspection Date: 06/13/2023 j Inspection Type: Rental Inspection Inspection Number: 10185 j Shift: N/A j Station: N/A Unit: N/A ! Lead Inspector: BARRY STRATTON j Other Inspectors: N/A I Fee: $50.00 / / / TJ� / 1(4 STATUS CODE DESCRIPTION FAIL 1010.2 - Door operations. Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON - Comments: All doors have become security doors with restricted access. Location: Not Provided FAIL 505.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. FAIL 506.1 - Where required. Inspector: BARRY STRATTON - Comments: Need addresses posted at entrances and on doors. Location: Not Provided Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire -fighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be of an approved type listed in accordance with UL 1037, and shall contain keys to gain necessary access as required by the fire code official. Inspector: BARRY STRATTON - Comments: Building has all doors secured with a key lock. Access to building is restricted. Need to install Knox Boxes at all entrances to building. Waterloo Fire was at apartment for a rnedical call and the tenant had to let the paramedics in. Location: All entrances Printed on 06113,2023 @ 1 i.12 Page 1 of 5 STATUS CODE DESCJUPTION FAIL 7041 Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids inthe following locations shall be maintained, The materials and systems shall besecurely attached noorbonded nothe adjacent construction, without openings visible through the construction. 1joints inor between fine-resioance'mtedwalls, floors orfloor/ceiling assemblies and roof o/ /nof/cei|in8assemb|ies. 2Join,siosmoke barriers. 3.Voidsatthe intersection of horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection ofavertical fire barrier and anexterior curtain wall. 7.Voids at the intersection ofavertical fire barrier and anonfi/e'/exisrance'ratedroof assembly. Unprotected joints and voids donot need nobeprotected where such joints and voids were not required robeprotected when the building was originally constructed. Where the system design number i»known, the system shall he inspected tothe listing criteria and manufacturer's installation instructions. Inspector: BARRY STRATTON - Comments: Door has no door knob. Still not corrected. Location: Entrance door to 236 FAIL 901]6.1 Standards. Fire protection systems shall beinspected, tested and maintained inaccordance with the referenced standards listed in Table 901.6.1. Inspector: BARRYSTK4TTON Comments: Nufire extinguishers inplace inhallways or Location: Not Provided P""°oon 06*12023m,nz Page 2mo STATUS ME DESCRIPTION FAIL 9861 Where required. Portable fire extinguishers shall beinstalled inall ofthe following locations: l]nnew and existing Group A,E\�F,H.|'M,R,1'R2 R-4and 5occupancies. Exceptions: lJn Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Iterns 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having aminimumrating of1`A:10'B:{.3]nGroup EOccupancies, portable fire extinguishers shall be required only in locations specified in items 2 through 6 where each classroom is provided with a portable fire extinguisher having aminimum rating of2,A:20'B:C3.|nstorage areas ofGroup Soccupancies where forklift, powered industrial truck o/powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall beapproved bythe fire code official. I2.Each vehicle shall beequipped with a1G- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection ofextinguishers. 3.5.Inspections ofvehicle- mounted exdnguishers»ha||bepedo/meddai|y. 2.VVithin3Ofeet (9144mm)distance of travel from commercial cooking equipment and from domestic cooking equipment inGroup |1;|'2.Condition 1;and R-Zcollege dormitory occupancies. I|nareas where flarnmable or combustible liquids are stored, used or dispensed. 4.On each floor of Structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.YVherere4uired bythe sections indicated inTable 9OO.1. 0.Speda|' hazardareas. including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a pot -table fire extinguisher suitable to the hazard of the location isprovided onthe vehicle ofvisiting personnel. Inspector: BARRYSTRATT0N Comments: None Location: Not Provided FAIL 915.1 General. Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.11through 915.6.Carbon monoxide detection shall beinstalled in existing buildings inaccordance with Secdon11O3.9. R2 - Unsafe Equipment Inspector: BARRY5TRATTON'Comments: No0}detector installed inZ3O Location: Not Provided Was the presence Of Unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPIVIC 108.1.2) Inspector: 8ARRv3TRATTON Comments: Water heater installed with non -approved gas pipe. Appliance gas pipe needs removed and black pipe needs to be installed. Location: Not Provided 'lin°u".061a20oCsn,z Page umn STArUS cost DESCRIPTION FAIL R4 Exterior Property Areas is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading andd/ainage sidewalks and driveways, weeds, and pest infestations. VPK4{30Z> Inspector: 8ARRY5TRATTON Comments: Gas leak at rear entrance of 236 Location: Not Provided FAIL K5 Exterior Structure |sthe exterior ofthe structure maintained ingood repair, structurally sound and sanitary state? (IPMC 304) Inspector: BARRY STRATTON - Comments: Window in mechanical room is broken and needs replaced. Still not done Location: Mechanical closet FAIL Rh Interior Structure Has the interior ofthe Structure and equipment inside been maintained ingood repair, structurally Sound, and in a sanitary condition? (IPMC 305) Inspector: BARRYSTRATT0N Comments: Water heater installed with flex gas pipe. Gas pipe needs nobeblack pipe. Location: Mechanical room FAIL R0A. Interior Structure- Were any unsafe conditions noted during the interior iospezion?(|PK4[}Ol11) Unsafe Conditions Inspector: BARRYSTRAlT0N Comments: Gas leak Location: Not Provided FAIL RiB. Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom temperature of68P(|PMC0O2.2) Inspector: 8ARRYSTRATT0N Comments: Furnace shuts down and will not run Location: Mechanical closet FAIL ROl. Mechanica|Eqiupment Are mechanical appliances properly installed and maintained in good working GENERAL NOTES Inspector: 8ARRYSTRATTON Comments: Water heater Location: Not Provided Plimed on m~,s2Oo(9:n:z Page *ms ~. ^ BARRYSTRATT0N 05/05/ O23@1212 No plumbing permits or inspections obtained for the installation of the new bathroom fixtures xemSpEcnVmoAre 07/18/2023 CONTACT SIGNATURE Matt Matthias INSPECTOR SIGNATURE 8ARRY STRATTON QUESTIONS ABOUT YOUR INSPECTION? 8ARRYSTKA7TON ba/ry.stmtton@water|oo'iaurg onmma2023 �n:z Page om5