RENTAL INSPECTION - 200-255 PARK VIEW BLVD - 6-13-23
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION FEE 1ST
$50.00
CUSTOMER #
24063
BILLING DATE
07/19/2023
DUE DATE
08/20/2023
INVOICE #
2024-00000022
CHARGES
$50.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$50.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
ATERLOO FIRE RESCUE
INSPECTION REPORT
PARK VIEW APARTMENTS, 200-255 PARK VIEW BLVD, WATER
DETAILS
�'Wdyosi101t vsa
�W
0 IA 50702 ct"h`
,a,,063 6°1-
Inspection Date: 06/13/2023 j Inspection Type: Rental Inspection Inspection Number: 10185 j Shift: N/A j Station: N/A
Unit: N/A ! Lead Inspector: BARRY STRATTON j Other Inspectors: N/A I Fee: $50.00 / / / TJ�
/ 1(4
STATUS CODE DESCRIPTION
FAIL 1010.2 - Door operations. Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON - Comments: All doors have become security doors with
restricted access.
Location: Not Provided
FAIL 505.1 - Address identification. New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property. Address identification characters shall
contrast with their background. Address numbers shall be Arabic numbers or
alphabetical letters. Numbers shall not be spelled out. Each character shall be not
less than 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm).
Where required by the fire code official, address identification shall be provided in
additional approved locations to facilitate emergency response. Where access is by
means of a private road and the building cannot be viewed from the public way, a
monument, pole or other sign or means shall be used to identify the structure.
Address identification shall be maintained.
FAIL
506.1 - Where required.
Inspector: BARRY STRATTON - Comments: Need addresses posted at entrances and
on doors.
Location: Not Provided
Where access to or within a structure or an area is restricted because of secured
openings or where immediate access is necessary for life-saving or fire -fighting
purposes, the fire code official is authorized to require a key box to be installed in an
approved location. The key box shall be of an approved type listed in accordance with
UL 1037, and shall contain keys to gain necessary access as required by the fire code
official.
Inspector: BARRY STRATTON - Comments: Building has all doors secured with a key
lock. Access to building is restricted. Need to install Knox Boxes at all entrances to
building. Waterloo Fire was at apartment for a rnedical call and the tenant had to let
the paramedics in.
Location: All entrances
Printed on 06113,2023 @ 1 i.12
Page 1 of 5
STATUS CODE DESCJUPTION
FAIL 7041 Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids inthe following locations shall be maintained, The
materials and systems shall besecurely attached noorbonded nothe adjacent
construction, without openings visible through the construction. 1joints inor
between fine-resioance'mtedwalls, floors orfloor/ceiling assemblies and roof o/
/nof/cei|in8assemb|ies. 2Join,siosmoke barriers. 3.Voidsatthe intersection of
horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the
intersection ofavertical fire barrier and anexterior curtain wall. 7.Voids at the
intersection ofavertical fire barrier and anonfi/e'/exisrance'ratedroof assembly.
Unprotected joints and voids donot need nobeprotected where such joints and
voids were not required robeprotected when the building was originally
constructed. Where the system design number i»known, the system shall he
inspected tothe listing criteria and manufacturer's installation instructions.
Inspector: BARRY STRATTON - Comments: Door has no door knob. Still not corrected.
Location: Entrance door to 236
FAIL 901]6.1 Standards. Fire protection systems shall beinspected, tested and maintained inaccordance with
the referenced standards listed in Table 901.6.1.
Inspector: BARRYSTK4TTON Comments: Nufire extinguishers inplace inhallways or
Location: Not Provided
P""°oon 06*12023m,nz
Page 2mo
STATUS ME DESCRIPTION
FAIL 9861 Where required. Portable fire extinguishers shall beinstalled inall ofthe following locations: l]nnew
and existing Group A,E\�F,H.|'M,R,1'R2 R-4and 5occupancies. Exceptions: lJn
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Iterns 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having aminimumrating of1`A:10'B:{.3]nGroup EOccupancies,
portable fire extinguishers shall be required only in locations specified in items 2
through 6 where each classroom is provided with a portable fire extinguisher having
aminimum rating of2,A:20'B:C3.|nstorage areas ofGroup Soccupancies where
forklift, powered industrial truck o/powered cart operators are the primary
occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in
accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall
beapproved bythe fire code official. I2.Each vehicle shall beequipped with a1G-
pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in
the proper operation, use and inspection ofextinguishers. 3.5.Inspections ofvehicle-
mounted exdnguishers»ha||bepedo/meddai|y. 2.VVithin3Ofeet (9144mm)distance
of travel from commercial cooking equipment and from domestic cooking equipment
inGroup |1;|'2.Condition 1;and R-Zcollege dormitory occupancies. I|nareas where
flarnmable or combustible liquids are stored, used or dispensed. 4.On each floor of
Structures under construction, except Group R-3 occupancies, in accordance with
Section 3316.1. 5.YVherere4uired bythe sections indicated inTable 9OO.1. 0.Speda|'
hazardareas. including but not limited to laboratories, computer rooms and
generator rooms, where required by the fire code official. Exception: Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a pot -table fire extinguisher suitable to the hazard of the location
isprovided onthe vehicle ofvisiting personnel.
Inspector: BARRYSTRATT0N Comments: None
Location: Not Provided
FAIL 915.1 General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.11through 915.6.Carbon monoxide detection shall beinstalled in
existing buildings inaccordance with Secdon11O3.9.
R2 - Unsafe Equipment
Inspector: BARRY5TRATTON'Comments: No0}detector installed inZ3O
Location: Not Provided
Was the presence Of Unsafe equipment noted during the inspection? Equipment may
include boilers, heating equipment, elevator, moving stairways, electrical wiring, and
flammable liquid containers. (IPIVIC 108.1.2)
Inspector: 8ARRv3TRATTON Comments: Water heater installed with non -approved
gas pipe. Appliance gas pipe needs removed and black pipe needs to be installed.
Location: Not Provided
'lin°u".061a20oCsn,z
Page umn
STArUS cost DESCRIPTION
FAIL R4 Exterior Property Areas is the exterior property area maintained in a clean, safe, and sanitary condition? This
includes grading andd/ainage sidewalks and driveways, weeds, and pest
infestations. VPK4{30Z>
Inspector: 8ARRY5TRATTON Comments: Gas leak at rear entrance of 236
Location: Not Provided
FAIL K5 Exterior Structure |sthe exterior ofthe structure maintained ingood repair, structurally sound and
sanitary state? (IPMC 304)
Inspector: BARRY STRATTON - Comments: Window in mechanical room is broken and
needs replaced. Still not done
Location: Mechanical closet
FAIL Rh Interior Structure Has the interior ofthe Structure and equipment inside been maintained ingood
repair, structurally Sound, and in a sanitary condition? (IPMC 305)
Inspector: BARRYSTRATT0N Comments: Water heater installed with flex gas pipe.
Gas pipe needs nobeblack pipe.
Location: Mechanical room
FAIL R0A. Interior Structure- Were any unsafe conditions noted during the interior iospezion?(|PK4[}Ol11)
Unsafe Conditions
Inspector: BARRYSTRAlT0N Comments: Gas leak
Location: Not Provided
FAIL RiB. Residential Heating Are dwellings provided with heating facilities capable ofmaintaining aroom
temperature of68P(|PMC0O2.2)
Inspector: 8ARRYSTRATT0N Comments: Furnace shuts down and will not run
Location: Mechanical closet
FAIL ROl. Mechanica|Eqiupment Are mechanical appliances properly installed and maintained in good working
GENERAL NOTES
Inspector: 8ARRYSTRATTON Comments: Water heater
Location: Not Provided
Plimed on m~,s2Oo(9:n:z
Page *ms
~. ^
BARRYSTRATT0N 05/05/ O23@1212 No plumbing permits or inspections obtained for the installation of the new bathroom
fixtures
xemSpEcnVmoAre
07/18/2023
CONTACT SIGNATURE
Matt Matthias
INSPECTOR SIGNATURE
8ARRY STRATTON