Loading...
HomeMy WebLinkAbout1202 W 2ND STREETOf Wq• 0 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/19/2023 08/20/2023 2024-00000018 $250.00 Customer #: 23001 QUALITY CONCRETE CONTRUCTION (RENTAL) 1930 HAWTHORNE AVE # 1 WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1202 W 2ND ST - 6-28-23 Description FOR BILLING INQUIRY: (319)291-4323 REINSPECTION FEE 3RD CUSTOMER # 23001 Total Price $250.00 BILLING DATE 07/19/2023 DUE DATE 08/20/2023 INVOICE # 2024-00000018 CHARGES Less Prepayment Total Due City of Waterloo $250.00 $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT QUALITY CONCRETE MULTI -RESIDENTIAL RENTALS, 1202 W 2ND ST, WATERLOO IA S0701 DETAILS Inspection Date: 06/28/2023 I Inspection Type: Rental Inspection 1 Inspection Number: 9590 I Shift: N/4 I Station: N/A Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $250.00 STATUS CODE DISCRIP FAIL 1018.1 - General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats, tables, furnishings, displays and similar fixtures or equipment. The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector: BARRY STRATTON - Comments: None Location: Not Provided FAIL 1031.2 Reliability Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON - Comments: Doors & Jambs Location: Not Provided FAIL 605.1 - Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON - Comments: Missing globes, electric panel needs access to panel, junk appliances in basement blocking egress path Location: Not Provided Printed on 06/23/2023 09:53 Page 1 of 4 SVAYUS CODE _uISCR FAIL 7031 Maintenance The required fire -resistance rating of fioe-reoioanmerated construction, including, but not limited to, walls, Orenmps,shaftenclosures, partitions, smoke barriers, floors, fire -resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems, shall be maintained. Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged, altered, breached or penetrated. Records of inspections and repairs shall be maintained. Where concealed, such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel, access door, ceiling tile or similar movable entry cothe space. Openings made therein for the passage ofpipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resista nce- rated assemblies shall be protected by self- or automatic -closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector: BARRYSTR/gT0N Comments: Ceiling inliving room, walls inliving room have water damage. Water damage nowalls and floors. Damaged material needs removed and replaced. Location: Not Provided FAIL 9061 Where required Portable fire extinguishers shall beinstalled hn all ofthe following locations: 1.|nnew and existing Group A,B'�F,H.|'Kd.K'1.R'2.R4and 5occupancies. Exception: In Group R-2 occupancies, pot -table fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having aminimum rating of1`A:10'B:[.2.Within 30feet (9144mm) of commercial cooking equipment. l |nareas where flammable urcombustible liquids are stored, used o/dispensed. 4. Oneach floor ufstructures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5� Where required bythe sections indicated inTable 9O61.O. Special -hazard areas, including but not limited to laboratories, computer roorns and generator rooms, where required by the fire code official. FAIL 9872.11 Single and multi ple-stadonsmoke alarms Inspector: BARRYSTRATT0N Comments: None Location: Not Provided Listed single- and multiple- station smoke alarms complying with UL217shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. Inspector: BARRY3TRAJTON Comments: None Location: Not Provided .;nzed on 0612&202s&' 09:53 Page 2m* nAVUS CODE DEscm/Pr/ FAIL 915.1 General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 9151.1through 915.0.Carbon monoxide detection shall beinstalled io existing buildings ioaccordance with Section 1103.9. Inspector: BARRY3TRATTON Comments: None Location: Not Provided FAIL R1 Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure? (IPMC 108.1.1) Inspector: BARRY5TRATT0N Comments: None Location: Not Provided FAIL R3'Unfit for Human Is the structure found tobefit for human occupancy according mthe code? (|PM{ Occupancy 108.1.3) Inspector: 8ARRYSTR/TT0N Comments: None Location: Not Provided FAIL R5 Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Inspector: BARRYSTR/QT0N Comments: Deck noentrance door and handrail on deck all need replaced Location: Not Provided FAIL RO Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Inspector: BARRYSTRATT0N Comments: Entry door needs replaced. jamb and door are broken. Broken windows need replaced. Egress path isblocked inkitchen because refrigerator isblocking path. Ceiling inliving room has collapsed. Ceiling tiles are damagedbywater leak. bath sink isriot secured nowall inbathroom. Sewer leak in basement needs repaired by licensed professional. Screen door does not have any door hardware. Back door to 1202 did not function because tenant advised it is broken. Security hardware tokeep door secured injamb i»broken and jamb not capable tokeep door secured and weather tight. Location: Not Provided FAIL R0�. Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRYSTRATTON Comments: Mold & water damage Printed onwum2023 �L 09,53 Page uov* STATUS CODE Location: Not Provided FAIL RiL Mechanica/Eqiupm*nt Are mechanical appliances properly installed and maintained ingood working ff*VfjtAl NOTES 8ARRYSTKAlT0N'OZ/02/2O23@1O:29 BARRYSTRAT[0N 00/ 8QO23@O9:52 ae/mSpsCr/omawrp O7/20/ZU23 CONTACT $16MAYmRa Quality Concrete Construction INSPECTOR SIGNATURE BARKY5TRATTON Signed on: 08/28/2023@O953 QuexrIONmABOUT YOUR INSPECTION? BARRYSTRATT0N bany.st/anun@waredoo'ia.oc§ Inspector: BARRYSTRATTON Comments: Maintenance nofurnace isneeded. Location: Not Provided Met onsite with Adam to show what needs to be corrected. Corrections still not complete _ Printe"on 0612312023 CE 09:53 Page *m4