Loading...
HomeMy WebLinkAbout264 BALTIMORE STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/19/2023 08/20/2023 2024-00000017 $250.00 Customer #: 23001 QUALITY CONCRETE CONTRUCTION (RENTAL) 1930 HAWTHORNE AVE #1 WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 264 BALTIMORE ST - 6-28-23 [ Description FOR BILLING INQUIRY: (319)291-4323 REINSPECTION FEE 3RD CUSTOMER # 23001 Total Price j $250.00 BILLING DATE 07/19/2023 DUE DATE 08/20/2023 INVOICE # 2024-00000017 CHARGES Less Prepayment Total Due —> City of Waterloo $250.00 $0.00 $250.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO J� �����W�������������������SCUE INSPECTION REPORT QUALITY CONCRETE CONCRETE CONSTRUCTION 4 FAMILY COWERSION, 264 BALTIMORE ST, WATERLOO IA 50701 Inspection Date: 06/28/2023 1 inspection Type: Rental Inspection I Inspection Number: 9591 1' Shift:,N/A)Station: Unit: N/A I Lead inspector: BARRY STRATTON I Other inspectors: N/A 1 Fee: $250.00 STATUS CODE DESCRIPTIOAf � FAiL 1010.1.9 Door operations Except as specifically permitted bythis section, egress doors shall bereadily openable from the egress side without the use of a key or special knowledge or Inspector: BARRYSTR4TTON Comments: Door uperadon/wearhehzadon.hardware for doors. Location: Not Provided FAIL 1031J Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction, and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use ofkeys ortools. Bars, grilles, grates orsimilar devices are allowed to be placed over emergency escape and rescue openings provided the minirnum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation ofthe emergency escape and rescue opening. Inspector: DARRYSTR/TT0N Comments: Windows screwed shut. Location: Not Provided FAIL 9061 Where required Portable fire extinguishers shall beinstalled inall nfthe following locations: 1.|nnew and existing Group �����1,/�R-1'R-lR-4and Soccupancies. Exception: N Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in|nems2through Owhere each dwelling unit isprovided with aportable fire extinguisher having aminimum rating of1`A:10'B:[.lWithin 30feet (9144mm) ofcommercial cooking equipment. I|nareas where flammab|eovcombustible liquids are stored, used ordispensed. 4.0neach floor ofstructures under construction, except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required bythe sections indicated inTable 9O8].0. Specia|'haza/dureas, including but not limited to |aborotories, computer ronmsand generator /oomx. where required hythe fire code official. Inspector: BARRYSTRATT0N Comments: None Location: Not Provided p�d On 061'_'&'Z023t 10 03 Page 1m3 sTAnm CODE ofsCRIPTION FAIL 9072.11 Single and Listed single- and multiple- station smoke alarms complying with UL 217 shall be mu/dp|e'staionsmoke installed inaccordance with Sections 9072.11.1through 907Z11 0andNFPA72 alarms Inspector: 8ARRY5TRATT0N [ommenczK4issing smoke detectors. Location: Not Provided FAIL 915.1 General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915. 6. Carbon monoxide detection shall be installed in existing buildings inaccordance with Section 11Ol9. Inspector: B4RRYSTRATT0N'Comments: None Location: Not Provided FAIL R4 Exterior Property Areas Is the exterior property area maintained in a clean, safe, and sanitary condition? This includes grading and drainage, sidewalks and driveways, weeds, and pest Inspector: BARRYSTR/QT0N Comments: Handrails onfront stairs still not repai/ed/ep|aced.Handrails donot meet code. Location: Not Provided FAIL RO Interior Structure Has the interior ofthe structure and equipment inside been maintained ingood repair, structurally sound, and inasanitary condition? (|PM[3O5) Inspector: BARRY5TRATTON Comments: Peeling paint, bath ceiling, holes infloors. Broken stairs treads still not replaced. 11WEIVEXAL NOmrES BARRYSTRA7T0N 06/28/ O23@1O:02 Location: Not Provided 403.2Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1, except that awindow shall not berequired /nsuch spaces equipped with amechanical ventilation system. Air exhausted by a mechanical ventilation systern from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated. 264 Baltimore Unit 8ARRY3TRATT0N 06/28/2023@10:02 204Baltimore St#3: Toilet needs re -set onfloor, entry way ceiling, peeling paint and abraded paint needs corrected. Smoke detectors needed installed to code. P,.nted=0&23,2023mma Page zmu ~ GENERAL NOTES DARRYSTRATT0N 06/28/2023@10:02 Z04Baltimore S,4: Smoke derecmrsneed installed oocode. Install globes onall lights in bUilding. CO Detector BARRYSTRATT0N 06/28/2023@10:02 Smoke detectors missing incommon hallways nem/spccnmmuAre 07/2O/2023 CONTACT SIGNATURE DaoReyenmn INSPECTOR SIGNATURE 0ARRYSTRATT0 QUESTIONS ABOUT YOUR INSPECTION? BARRYSTRAlTON barry.strauon@wa,er|uo'ia.orO Printed on 06i2afZ023�1,0:03 Page 3m3