Loading...
HomeMy WebLinkAbout402 1/2 WELLINGTON STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/19/2023 08/20/2023 2024-00000014 $150.00 Customer #: 22306 LDN PROPERTIES L L C PO BOX 2094 Waterloo, IA 50704 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 402 1/2 WELLINGTON ST - 5-23-23 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION FEE 2ND $150.00 CUSTOMER #_ BILLING DATE DUE DATE INVOICE'# CHARGES 22306 07/19/2023 08/20/2023 2024-00000014 $150.00 Less Prepayment Total Due — City of Waterloo $0.00 $150.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT 400-402 WELLINGTON ST 4 PLEX, 402 1/2 WELLINGTON ST, DETAILS ATERLOO IA 50701 �1 () Inspection Date: 05/23/2023 I Inspection Type: Rental Inspection I Inspection Number: 10105 I Shift: N/j tion: N/A I ai14( Unit: N/A I Lead Inspector: BARRY STRATTON I Other Inspectors: N/A I Fee: $150.00 c/ /„ STATUS CODE DESCRIPTION FAIL 603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector: BARRY STRATTON - Comments: Open electric boxes in closet and basement. Romex in closet need to be in rigid pipe. Location: Not Provided P,,,ntetl on 05 2312023 ;2: 11.43 Page 1 of 4 sc4Ta CODE DESCRIPTION 906.1 Where required. FAIL 9072.11 Single- and multi p|estadonsmoke alarms. Portable fire extinguishers shall be installed in all of the following locations: 1.1n new and existing Group A,E\�F,H.1, M.R'1'R-2.R-4and Soccupancies. Exceptions: 1J11 Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Iterns 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having aminimumrating of1`A:1U'Bl.2]nGroup Eoccupancies, portable fire extinguishers shall be required only in locations specified in Items through 6 where each classroom is provided with a portable fire extinguisher having aminimum rating ufZ-A:20'BI.3.|nstorage areas ofGroup Soccupancies where h//k|ht' powered industrial truck o/powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall heapproved bythe fire code official. J.Z.Each vehicle shall beequipped with a10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection ofextinguishers. 3J.Inspections ofvehicle- mounted exdngui»he/»»haUbepedo/meddai|y.2.wNth{n3Oher(9144mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flarnmable or combustible liquids are stored, used or dispensed. 4.On each floor of struoues under construction, except Group R'3ooupandes, inaccordance with Section l31615.Whenerequired bythe sections indicated inTable 9OO10.Speda|' hazard areas, including but not limited no laboratories, computer roomsand generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location ioprovided onthe vehicle ofvisiting personnel. Inspector: BARRYSTRATTON Comments: None Location: Not Provided Listed single- and multi p|e-smtioosmoke alarms complying with UL217shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. Inspector: BARRYSTRATTON [unmoms: Smoke detectors need noinstalled and in working condition. Old detectors need removed, Location: Not Provided FAIL 915.1 'Generai Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6. Carbon monoxide detection shall be installed in existing buildings inaccordance with Section 11O3.9, Inspector: BARnvsTnATTow Comments: O]Detector needed invicinity of bedrooms, Location: Not Provided P,inted=ns23uo23 �n,m Page um* *YATU$ CODE ocSCamnom RAIL R5 Exterior Structure is the exterior ofthe structure maintained ingood epair,omc sanitary state? (IPMC 304) ura ly sound and Inspector: BARRYSTRATTON Comments: Front porch co|umnandfroncstaio.Rnnt stairs unsafe and need replaced. Location: Not Provided FAIL R5 Interior Structure Has the interior ofthe structure and equipment inside been maintained ingood repair, structurally Sound, and in a sanitary condition? (IPMC 305) Inspector: BARRY5TRATT0N Comments: Back door jambneeds replaced, broken windows need replaced, door hardware missing on doors, peeling paint, paneling is coming loose from wall, holes infloor, mice and cockroaches, drainage pipe in kitchen sink leaks and pipe not allowed per plumbing code, rotten duct work in basement,water meter leaking, cardboard screwed inzodryer not venting to the outside.d/yvaUoeedsinstaUedoopatchhn|ein»cai/way,porchco|umnneeds replaced. Location: Not Provided FAIL Ni[ Mechanical Eqiupment Are mechanical appliances properly installed and maintained ingood working condition? (|PM[d031) Inspector: BARHYSTRAlT0N Comments: None Location: Not Provided GENERAL NOTES BARRYSTKATFON 05/23/2023@11:38 84RRYSTRATTON 05/23/ 023@1138 309.1 Infestation. Structures shall bekept free from insect and rodent infestation. Structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health. After pest elimination, proper precautions shall hetaken zoprevent reinfesmdon. 3051 General. The intho/ofastruouoeandequipnaerttheeinshaUbemaimainedin good repair, structurally sound and in a sanitary condition. Occupants shall keep that part of the structure that they occupy or control in a clean and sanitary condition. Every owner of a structure containing a roorning house, housekeeping units, a hotel, a dormitory, two or more dwelling units or two or more nonresidential occupancies, shall maintain, in a clean and sanitary condition, the shared or public areas of the structure and exterior property 3O4AStructural members. Structural members shall bemaintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads. Front pillar and front steps need replaced. Printed =M23uu23mn,43 Page 8ux4 GENERAL NOTES BARRYSTRATTON 05/23/2023@11:43 5041 GenemiPlumbing fixtures shall beproperly installed and maintained inworking order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. Broken pipe between units. BARRYSTRATT0N 05/23/202]@11:]9 805.1 Installation. Electrical equipment, wiring and appliances shall beproperly installed and maintained inasafe and approved manner. BARRYSTKATT0N 05/23/ 023@1139 9�-6:DENIAL, SUSPENSION, REVOCATION ORN0NRENEYYAL BARRYSTRATT0N 05/23/2023@1139 ae/NSPEcrmmDATE 06/27/2023 CONTACT SIGNATURE LDNProperties LL[ INSPECTOR SIGNATURE BARRYSTRATT0N QUESTIONS ABOUT YOUR INSPECTION? BARRYSTR4lTON ba/ry.staUon@wanedoo'ia.o/g 9-7-9: OWNER AND TENANT RESPONSIBILITIES: A. Landlord: Every landlord or its agent, in addition to being responsible for maintaining each rental unit in sound oruom/a| condition, shall beresponsible for keeping that part ofthe building n/premises which it controls in dean' sanitary and safe condition, including the shared orpublic areas in a building containing two (2) or more rental units. In addition, every landlord or its agent shall comply with the provisions of title 5, chapter 3, article B of this code, granting housing protections tovictims ofdomestic violence. -5f p,inteuono51zNz02,�x,o Page *or*