RENTAL INSPECTION - 1133 DIXON DR - 6-27-23
[ Description
FOR BILLING INQUIRY: (319)291-4323
REINSPECTION FEE 3RD
Total Price
$250.00
CUSTOMER #
24076
BILLING DATE
07/19/2023
DUE DATE
08/20/2023
INVOICE #
2024-00000013
CHARGES
$250.00
Less Prepayment
Total Due -->
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
thr1)\--
WATERLOO FIRE RESCUE �1 t`ALA) Ut
INSPECTION REPORT V i
1125-1133 DIXON DRIVE CONDOMINIUMS BLDG, 1133 DIXON DR, WATERLOO IA 5tI701 f\ X r
DETAILS
Inspection Date: 06/27/2023 I Inspection Type: Rental Inspection I Inspection Number: 10317 I Shift: N/A I Station: N/A
Unit: N/A j Lead Inspector: BARRY STRATTON I Other Inspectors: N/A { Fee: $250.00 , 4 /
STATUS CODE DESCRIPTION
FAIL 1008.1 - Means of egress Illumination shall be provided in the means of egress in accordance with Section
illumination. 1008.2. Under emergency power, means of egress illumination shall comply with
Section 1008.3.
Inspector: BARRY STRATTON - Comments: Egress lighting does not work. Today's
inspections lights still do not work.
Location: Not Provided
FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied. An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector: BARRY STRATTON - Comments: Front door threshold is obstructing door
from closing. Threshold is still not repaired.
Location: Not Provided
FAIL 603.2 - Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring, devices, appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector: BARRY STRATTON - Comments: AC disconnect box on East side of building
is hanging by wires. Box needs secured to building. AC disconnect box still hanging
from building. Today's inspection one deck screw held box to siding. When checking
box it pulled off screw. Box still hanging not secured to building
Location: Not Provided
Printed on 06727;2023 12.34
Page 1 of 4
STATVS co" DESCRIPTION
FAIL 7043 0peningpnocectives Where openings are required nobeprotected, opening p/oc chvesshaUhe
maintained self -closing or automatic -closing by smoke detection. Existing fusible-link-
typeaunomahcdoor-dosingdevicesanepe/mittedifthehusib|e|ink/adngdoesnoc
exceed 135^F(57~[).
Inspector: 8ARRYSTRATTON Comments: Fire doors inopen position. Fire doors still
left in the open position on todays inspection, may require door closures installed on
doors.
Location: Not Provided
FAIL 901.6'inspection, testing and Fire detection and alarm systems, eme/gencyalarm systems, gas detection systems,
maintenance. fire -extinguishing systems, mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall hemaintained inanoperative condition
at all times, and shall be replaced or repaired where defective. Nonrequired fire
protection and life safety systems and equipment shall be inspected, tested and
maintained orremoved inaccordance with Section 9O1.8.
Inspector: BARRYSTRATT0N Comments: Alarm need maintenance and testing.
Alarm testing still requires tested,
Location: Not Provided
P,nte=�06�217,=3 ��`134
Page om*
STATUS CODE DESCRIPTION
FAIL 9001'Where required. Portable fire extinguishers shall heinstalled inall ofthe following locations: 1.1n nam
and e�»bngGroup A,E\E�H.|.Kx.R,1'�2.�4and Soccupandes.Excepdos:1Jn
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in|nams2 through Owhere each dwelling unit i»provided with aportable
fire extinguisher having aminimumrating of1'A:10'BI.Z]nGroup Eooupanday
ponab|efire exhngui»he/sshaUberequired on�in/ooadonsspech5ed/n|em»2'
through 6 where each classroom is provided with a portable fire extinguisher having
aminimum rating ofZ+A:20'BI.3.|nstorage areas ofGroup Soccupancies where
forklift, powered industrial truck o/powered cart operators are the primary
occupants, fixed extinguishers, asspecified inmFPA10,shall not berequired where in
accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall
oeapproved bythe fire code official. lZ.Each vehicle shall beequipped with a10-
pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on -site toreplace adischarged extinguisher. 3.4.Vehicle operators shall hetrained io
the proper operation, use and inspection ofextinguishers. l5.Inspections nfvehicle-
mounted exdnguisheosha||hepe/fonneddai|y.lVVirh(n3Ofeec(9144nnn)disrance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.1n areas where
flammable or combustible liquids are stored, used or dispensed. 4.0n each floor of
structures under construction, except Group R-3 occupancies, in accordance with
Section 331O.1.5.YVhererequired bythe sections indicated inTable 9061.0.3pecia|'
hazardaeas.indudingburncn|imitedro|aborannhes'compune/noomsand
generator rooms, where required by the fire code official. Exception: Pot -table fire
extinguishers are not required at normally unmanned Group U Occupancy buildings
or structures where a pot -table fire extinguisher suitable to the hazard of the location
i»provided onthe vehicle ofvisiting personnel.
R4 - Exterior Property Areas
FAIL R6 - Interior Structure
GENERAL NOTES
Inspector: 8ARRYSTRATT0N'Comments: Fire Extinguishers need updated. (2021).
Fire extinguishers still out of date (2021).
Location: Not Provided
|sthe exterior property area maintained inaclean, Safe, and sanitary condition? This
includes grading and drainage, sidewalks and driveways, weeds, and pest
infestations. (|PK4C3O2)
Inspector: BARRYSTRATT0N Comments: Front concrete slab atdoor, Busted
concrete missing that is under slab. Concrete slab still broken and needs repaired.
Location: Not Provided
Has the interior ofthe structure and equipment inside been maintained ingood
repair, structurally sound, and inasanitary condition? (|PN1[3U5)
Inspector: BARRYSTRxTT0N Comments: Egress lights, fire extinguishers, fire doors,
front door threshold.
Location: Not Provided
PIMEed =06127;2023m'2:34
Page um^
~' ^
BARRY5TRATTUN 06/ 7/lO23@1233 Photos obtained ofA{disconnect, lights not working and front landing condition.
REINSPECTION DATE
07/25 023
cwmrucrmoxmruxr
[a|iberGroup
INSPECTOR SIGNATURE
BARRYSTKATTON
QUESTIONS ABOUT YOUR INSPEC7ION?
BAKRYSTRATTON
baoy.stratton@watedoo'/a»rg
~m° �����i-1,2: 3,4