Loading...
HomeMy WebLinkAbout3026 ANSBOROUGH AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000020 $80.00 Customer #: 24742 PINK CLOUD SMOKE SHOP 3026 ANSBOROUGH AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3026 ANSBOROUGH AVE - 6-25-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24742 07/09/2025 08/12/2025 2026-00000020 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WatgtlnoFirg escue Inspection Repo Pink Cloud Smoke Shop - 3026 Ansborough A , BLDG 3026 Ansborough Ave - STE B, Waterloo IA 50701 SPEC • •ETAILS Inspection Date 06125/2025 eadd Inspector Bract -Baldwin Other Inspectors NIA nspection Type Annual Inspection (1Yr) Shift NIA 425 E. 3rd Street Inspection Number 8038 Station Unit NIA NIA SUMMARY OF INSPECTION 036 Passed codes NEXT STEPS 0 9 Failed codes 31 NIA codes Please direct questions about your Inspection to: Brad Baldwin brad.baldwin@waterloo-ia.org, 3192914319 AL NOTES J� Brad Baldwin - 06/26/2025 @ 09:12 $80 annual inspection fee Brad Baldwin - 06/26/2025 @ 10:05 a€6 Commercial Fire Inspector a€" brad.baldwin@waterloo-ia.org a€" Work: 319-291-4319 (#5) - CeII: 319-230-1224 Brad Baldwin - 0612612025 @ 10:05 Reinspection Date 07117/2025 a€6 Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected Brad Baldwin - 06/26/2025 @ 10:05 ACC If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 9:00 a.m. a€" 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Aftab Afribi (2025) Date: Brad Baldwin 06/2612025 CHECKLISTS GENERATED ON 6/26/25, 10:07 AM 1 OF 6 Means of Egress yi-rIUs; Cud. 1010.1.3 The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Additional Codes Status Code Fail 102.3 A change of occupancy shall not be made unless the use or occupancy is made to comply with the requirements of this code and the International Existing Building Code . Exception: Where approved by the fire code official, a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code , provided that the new or proposed use or occupancy is less hazardous, based on life and fire risk, than the existing use or occupancy. Description Location: Back exit door Comments: Repair or replaced door, required special force to open. If replaced, obtain proper building permit and inspections by licensed contractor. Description Location: Back storage room Comments: NO SLEEPING IN BUILDING. REMOVE ALL BEDDING AND MATRESSES IMMEDIATELY GENERATED ON 6/26/25, 10:07 AM 2 OF 6 General Housekeeping Status Code Fail 315.3.2 Combustible materials shall not be stored in exits or enclosures for stairways and ramps. Combustible materials in the means of egress during construction, demolition, remodeling or alterations shall comply with Section 3312.3. Electrical Safety Status God Fail Fail 0 603.2.2 Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.5.3 Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Description Location: Back storage exit Comments: Remove pallet from path of egress. Description Comments: Several wire splices noted throughout store shall be removed and replaced with permanent wiring by licensed electrical contractor by obtaining permits and inspections. Comments: Appliances shall be directly plugged into wall outlet. Power strips shall be properly mounted on wall surface or supported to avoid hanging by wires, power strips shall not lay across walking surface. GENERATED ON 6/26/25, 10:07 AM 30E6 Fire Resistant Construction Maintenance Status Code Fail Fail 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Electrical panel room Comments: Replace missing ceiling tiles Location: Bathroom Comments: Replace missing ceiling tiles GENERATED ON 6/26/25, 10:07 AM 4 OF 6 Fail 704.1 Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Portable Fire Extingusihers Status Code Fail 906.1 Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, 1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Location: Back storage rooms Comments: Replace missing ceiling tiles Description Comments: Provide two fire extinguishers properly installed on wall brackets, extinguishers shall be installed within 75 feet of the next. Self purchased extinguishers shall have copy of receipt to show purchase date, contractor purchased extinguishers provide required tag. GENERATED ON 6/26/25, 10:07 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 6/26/25, 10:07 AM 6 OF 6