Loading...
HomeMy WebLinkAbout827 FISHER DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000018 $100.00 Customer #: 24741 LIVING HOPE CHURCH 827 FISHER DR WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 827 FISHER DR - 5-2-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24741 07/09/2025 08/12/2025 2026-00000018 $100.00 Less Prepayment Total Due — City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report LIVING HOPE CHURCH - 827 fisher DR, BLDG 827 Fisher Dr, Waterloo IA 50701 INSPECTION DETAILS ✓ Inspection Date 051021 Lead Inspector JEREMIAH VANDYKE inspection Type Annual Inspection (1Yr) Street Inspection Number 562 Other Inspectors NIA Shift NIA Station NIA Unit NIA SUMMARY OF INSPECTION 046 Passed codes NEXT STEPS 0 7 Failed codes 22 NIA codes Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org FEE Invoice Date Inspection Fee NIA $100.00 Date Paid Amount Paid Reinspection Date 0610112025 Invoice Number Check Number Transaction Number N/A NIA N/A GENERAL NOTES JEREMIAH VANDYKE - 05/02/2025 @ 17:23 Fire extinguishers serviced by Hawkeye Fire & Safety April 2025. JEREMIAH VANDYKE - 05/02/2025 @ 17:23 4/17/2025 S - (Annual) Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE - 05/02/2025 @ 17:23 8/22/2024 S - 5 Year Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE - 0510212025 @ 17:24 4123/2024 S - (Annual) Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE - 05/0212025 @ 17:53 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone # 319-291- 2515. JEREMIAH VANDYKE - 05102/2025 @ 17:53 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday A€" Friday, 8:00 a.m. AC" 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 0510212025 @ 17:53 GENERATED ON 5/2/25, 12:55 PM 1 OF 3 Lt. Van Dyke - jeremiah.van g-&€" Work; 319-291-4460 - ell: 319-883-1615 JERE . - VANDYKE - 05102120284 17:53 nspection Fee = $100.00 (To be mailed out by City via snail mail.) SIGNATURES Conta nature No signature NA TOM HLAD - Pastor CHECKLISTS Means of Egress Status Fail F� Code Inspector signature Date: JEREMIAH VANDYKE 1004.9 Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space, for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owners€T"s authorized agent. Additional Codes Status Fail 0 Fail Code 102.3 A change of occupancy shall not be made unless the use or occupancy is made to comply with the requirements of this code and the International Existing Building Code . Exception: Where approved by the fire code official, a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code , provided that the new or proposed use or occupancy is Tess hazardous, based on life and fire risk, than the existing use or occupancy. 904.4 Automatic fire -extinguishing systems shall be inspected and tested in accordance with the provisions of this section prior to acceptance. Emergency Equipment Status Fail 0 Code 1203.2.15 Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Description 05/0212025 Location: Occupancy sign Comments: Will need architect (Dan Levi) plans for occupancy in current room being used for worship. Description Location: Entire building. Comments: Will need Architect (Dan Levi) to verify plans for building due to change of use. Discussed with Greg Alhelm and FM Brock Weliver. Location: Special Suppression System. Comments: Discussed getting Hawkeye Fire and safety to take Special Suppression system out of service. Will need verification that system has been taking out of service. Description Location: Entire Building. Comments: Egress lighting was tested and failed. Will contact license electrican to repair and figure out back up system. GENERATED ON 5/2/25, 12:55 PM 2 OF 3 Fail 1203.4.3 Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Electrical Safety Status Fail 0 Code 603.5.2 Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fire Resistant Construction Maintenance Status Fail 0 Code 704.1 Where required when the budding was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: All Exit and Egress lights in entire building. Comments: Gene will contact licensed electrician on egress lights and how to use the testing system. Need a workorderlinvoice of the exit and egress lights are properly working. Description Location: Sound booth area in corner of worship room. Comments: Had extension cord plugged into powerstrip (Daisy chain) that needs to be removed. Discussed getting powerstrip with longer cord. Description Location: F1 N35 janitor & Hallway going to large open office area near F1-K30. Comments: Ceiling tiles missing and needs replaced. GENERATED ON 5/2/25, 12:55 PM 3 OF 3