Loading...
HomeMy WebLinkAbout4051 UNIVERSITY AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000002 $100.00 Customer #: 24739 "CHURCH" 4051 UNIVERSITY AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 4051 UNIVERSITY AVE - 6-23-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION 1 Total Price $100.00 CUSTOMER # 24739 BILLING DATE 07/09/2025 DUE DATE 08/12/2025 INVOICE # 2026-00000002 CHARGES $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Repo hurch - 4051 University AVE, B DG 4051 University Ave, Waterloo IA 50701 (INSPECTION TAILS Inspection Date, \ 06123/2025 f ` i Insp for Brad Baldwin Other Inspectors NIA Inspection Type Annual Inspection (1Yr) ; REINSPECTION Shift NIA 425 E. 3rd Street Inspection Number 7418-R1 Station Unit NIA N/A SUMMARY OF INSPECTION 0 Passed codes NEXT STEPS Q 18 Failed codes Please direct questions about your Inspection to: Brad Baldwin brad.baldwin@waterloo-ia.org, 3192914319 Brad Baldwin - 0612412Q25 @ 07:43 $100 re -inspection fee, failure to show for scheduled inspection on 6/23/25 at 1:30pm. Reinspection Date 07/16/2025 Brad- Bat - 051 2025 @ 15:09 -Re-inspection dates are automatically generated 30 days out from the initial inspection. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 9:00 a.m. a€" 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. - Brad Baldwin - 05/13/2025 @ 15:09 -Property Safety Inspector a€" brad.baldwin@waterloo-ia.org a€" Work: 319-291-4319 Brad Baldwin - 05113/2025 @ 15:09 $80 Annual inspection fee SIGNATURES Contact signature Inspector signature John Latdrik (Pastor) CHECKLISTS No signature Report completed post inspection Date: Brad Baldwin 0612412025 GENERATED ON 6/24/25, 8:13 AM 1 OF 6 Reinspection Status Code Fail Fait cpc Fail Fail 0 Fail Fail Fail /Fail 1004.9 Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space, for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owners€" s authorized agent. 102.3 A change of occupancy shall not be made unless the use or occupancy is made to comply with the requirements of this code and the International Existing Building Code . Exception: Where approved by the fire code official, a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code , provided that the new or proposed use or occupancy is less hazardous, based on life and fire risk, than the existing use or occupancy. 102.4 The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 102.4 The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 1203.2.15 Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 5.2.1 Sprinklers shall be inspected at least annually by licensed contractor 5.2.1.1.5 Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. Desci p on Location: Occupant load posting Comments: Occupant load shall be reviewed by licensed designed professional. Report shall be sent to fire inspector. Location: Change of occupancy Comments: Change of occupancy must be reviewed by a licensed design professional. Report by professional shall be submitted to be reviewed by City Building Official. Location: Walls constructed in SE corner Comments: Walls constructed without building permit. Obtain architect to submit plans for review of by City Building Official Location: Walls constructed outside women's bathroom Comments: Walls constructed without building permit. Obtain architect to submit plans for review of by City Building Official Location: Exit sign near alter Comments: Exit light above front entrance doors failed testing, repair or replace. Location: Front entrance exit light Comments: Exit light above front entrance doors failed testing, repair or replace. Location: Sprinkler system Comments: Complete sprinkler system testing and inspection, currently past due 578 days as of 5113/25. Contractor must upload report online to Compliance Engine Location: Northwest corner sprinkler escutcheon Comments: Install sprinkler escutcheon properly GENERATED ON 6/24/25, 8:13 AM 2 OF 6 Fail x Fail x Fail Fail 509.2 Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 603.5 Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5.2 Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.5.3 Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. 603.6 Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Sprinkler riser room Comments: Remove all storage. Location: All multiplug adapters and cords Comments: Multiplug adapters and multiplug cords shall be removed. Location: All power strips Comments: All power strips shall be plugged directly to wall receptacle. Location: Near posts in center of building and near front wall. Comments: Cords running through ceiling grids shall be permanently removed. Location: Several extension cords noted Comments: Remove all extension cords. GENERATED ON 6/24/25, 8:13 AM 3 OF 6 807.2 In Groups A, B, E, 1, M and R-1 and in dormitories in Group R- 2, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall comply with Section 807.3 and shall not exceed 10 percent of the specific wall or ceiling area to which such materials are attached. Fixed or movable walls and partitions, paneling, wall pads and crash pads applied structurally or for decoration, acoustical correction, surface insulation or other purposes shall be considered to be interior finish, shall comply with Section 803 and shall not be considered decorative materials or furnishings. Exceptions: 1.1n auditoriums in Group A, the permissible amount of curtains, draperies, fabric hangings and similar combustible decorative material suspended from walls or ceilings shall not exceed 75 percent of the aggregate wall area where the building is equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, and where the material is installed in accordance with Section 803.15 of the International Building Code. 2.In Group R-2 dormitories, within sleeping units and dwelling units, the permissible amount of curtains, draperies, fabric hangings and similar decorative materials suspended from walls or ceilings shall not exceed 50 percent of the aggregate wall areas where the building is equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1. 3.In Group B and M occupancies, the amount of combustible fabric partitions suspended from the ceiling and not supported by the floor shall comply with Section 807.3 and shall not be limited. 4.The 10-percent limit shall not apply to curtains, draperies, fabric hangings and similar combustible decorative materials used as window coverings. Location: Wall coverings near alter Comments: Verify draperies meet flame spread requirements GENERATED ON 6/24/25, 8:13 AM 4 OF 6 Fail Fail Fail x 906.1 Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, 1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Chapter 14 Fire alarm system tested at least annually by licensed contractor Table 8.1.1.2 Fire pump being tested (run)? Weekly for diesel/monthly for electric. Additional Codes sehz:s Code Fail X1 102.4 The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: Fire extinguishers Comments: Install fire extinguishers where required by code. Copy of receipt shall be kept for purchase of fire extinguishers Location: Fire alarm system Comments: Complete fire alarm system testing and inspection, currently past due 388 days as of 5/13/25. Contractor must upload report online to Compliance Engine Location: Sprinkler system testing & inspection Comments: Complete sprinkler system testing and inspection, currently past due 578 days as of 5/13/25. Contractor must upload report online to Compliance Engine. Description Location: Wall constructed separating church from south area of building Comments: Wall constructed without building permit. Obtain architect to submit plans for review by of by City Building Official. GENERATED ON 6/24/25, 8:13 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee N/A $100.00 Date Paid Amount Paid Invoice Number Check Number NIA NIA Transaction Number N/A GENERATED ON 6/24/25, 8:13 AM 6 OF 6