Loading...
HomeMy WebLinkAbout1104 WASHINGTON STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 07/09/2025 08/12/2025 2026-00000016 $80.00 Customer #: 14228 KWIK STOP #3 1104 WASHINGTON ST WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1104 WASHINGTON ST - 6-25-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE CUSTOMER # 14228 Total Price $70.00 $10.00 BILLING DATE 07/09/2025 DUE DATE 08/12/2025 INVOICE # 2026-00000016 CHARGES Less Prepayment Total Due —� City of Waterloo $80.00 $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent Tate fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report\ Kwik Stop 3 - 1104 Washington St, BLDG 1104 Washington St - STE A, Waterloo IA 50702 INSPECTION -DETAILS" — inspection Date 06/25/2025 adInspector Br.: n Other Inspectors NIA Inspection Type glnnual Inspection (1Yr) 425 E. 3rd Street Inspection Number 14216 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 29 Passed codes NEXT STEPS CD 11 Failed codes 0 34 NIA codes Please direct questions about your Inspection to: Brad Baldwin brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES Brad Baldwin - 0612612025 @ 07:50 $80 annual inspection fee Brad Ba wiff=0572V2025 @ 07:50 ACC Commercial Fire Inspector a€" brad.baldwin@waterloo-ia.org a€" Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 07/17/2025 Brad Baldwin - 06/2612025 @ 07:50 a€rC Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected Brad Baldwin - 06/2612025 @ 07:50 ACC If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday a€" Friday, 9:00 a.m. a€" 4:00 p.m. ****'Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Mohammad ILYAS Date: _ Brad Baldwin 06/26/2025 CHECKLISTS GENERATED ON 6/26/25, 8A8 AM 1 OF 9 Means of Egress Status Code Fail 1032.2 Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Description Location: Back storage area exit Comments: Remove obstructions to clear path of egress. Second exit in storage area is not required per square footage . Removal of exit sign would be approved per City Building Official, removal would require wires properly capped in box with cover. GENERATED ON 6/26/25, 8:48 AM 2 OF 9 General Housekeeping Status Code Fail 0 315.3.1 Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. Exceptions: 1.The 2-foot (610 mm) ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings. 2.The 18-inch (457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. Location: Back storage room Comments: Remove storage within 24" from ceiling. Storage shall be neatly stacked to avoid tip over hazard. GENERATED ON 6/26/25, 8:48 AM 3 OF 9 Fail 315.4.1 Where buildings are protected by an automatic sprinkler system, the outdoor storage, display and handling of combustible materials under eaves, canopies or other projections or overhangs are prohibited except where automatic sprinklers are installed under such eaves, canopies or other projections or overhangs. Location: Front entrance Comments: Remove firewood and all combustible material from under eave of building. GENERATED ON 6/26/25, 8:48 AM 4 OF 9 Electrical Safety Status :`odor Fail Fail x 603.2 Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2 Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: "Fish Game" near front of store Comments: Remove game appliance cord running across floor to avoid damage to cord. Location: South exterior near exhaust discharge Comments: Repair or replace damaged wiring and conduit. GENERATED ON 6/26/25, 8:48 AM 5 OF 9 Fail Fail 0 603.2.2 Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4 A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Alcohol cooler Comments: Provide moisture proof cover for cooler light fixture Location: Back storage near electric panel Comments: Remove obstructions within 36" in front of electric panels, maintain clearances at all times. GENERATED ON 6/26/25, 8:48 AM 6 OF 9 Fail 603.5 0 Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Fail 603.5.2 0 Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Location: Near "fish game" at front of store Comments: Properly hang or support power strip to avoid hanging by wires. Appliances shall be plugged directly to wall outlets Location: Under counter near register Comments: Remove power strips daisy chained, power strips shall have manual reset and plugged directly to wall outlet. GENERATED ON 6/26/25, 8:48 AM 7 OF 9 Portable Fire Extingusihers Status Code Fail Fail 906.2 Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.7 Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer.€Cr's installation instructions, Descr p on Location: All fire extinguishers Comments: Provide fire extinguishers service, due by June 2025. Location: Under counter near "Fish game" Comments: Fire extinguisher shall be properly mounted on wall bracket no less than 4" from floor, no more in height than 5' from floor GENERATED ON 6/26/25, 8:48 AM 8 OF 9 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA N/A GENERATED ON 6/26/25, 8:48 AM 9 OF 9